YS/T 281.1-2011Methods for chemical analysis of cobalt. Part 1: Determination of iron content. Sulfosalicylic acid spectrophotometry (English PDF)
钴化学分析方法 第1部分:铁量的测定磺基水杨酸分光光度法
This is a limited preview
Buy now to download the full PDF (5 pages)
Need quotation for your management?
Get a formal quotation for YS/T 281.1-2011 in 30 minutes.
Issued by
Ministry of Industry and Information Technology
Level / Type
National · Recommended
Issue date
December 20, 2011
Implementation date
July 1, 2012
Scope
YS/T 281.1-2011 is the English-translated version of 钴化学分析方法 第1部分:铁量的测定磺基水杨酸分光光度法.
YS/T 281.1-2011 — This section YS/T 281 specifies the method for determination of cobalt in iron content. This section applies to the determination of iron content in cobalt. Measurement range. 0.00080% to 0.70%.
Found what you need?
Document preview — YS/T 281.1-2011
National Standard of the People's Republic of China
- ICS
- 77.120.70
- Classification
- H 13
- Replacing
- YS/T 281.1-1994
Issued by: Ministry of Industry and Information Technology
Contents
- Foreword
- 1 Scope
- 2 Method summary
- 3 Reagents
- 4 Instrument
Foreword
YS/T 281 "cobalt chemical analysis method" is divided into the following 20 sections.
--- Part 1. Determination of iron content sulfonic acid spectrophotometry
--- Part 2. Determination of the amount of chrome aluminum Azure S Spectrophotometry
--- Part 3. Determination of silicon content - Molybdenum blue spectrophotometric method
--- Part 4. Determination of arsenic content - Molybdenum blue spectrophotometric method
--- Part 5. Determination of phosphorus content - Molybdenum blue spectrophotometric method
--- Part 6. Determination of magnesium content - Flame atomic absorption spectrometry
--- Part 7. Determination of zinc content - Flame atomic absorption spectrometry
--- Part 8. Determination of cadmium content by flame atomic absorption spectrometry
--- Part 9. Determination of lead content - flame atomic absorption spectrometry
--- Part 10. Determination of nickel content by flame atomic absorption spectrometry
--- Part 11. Flame atomic copper, manganese content absorption spectrometry
--- Part 12. arsenic, antimony, bismuth, tin, lead and determining the amount of electrothermal atomic absorption spectrometry
--- Part 13. Determination of sulfur content high frequency induction furnace combustion infrared absorption method
--- Part 14. Determination of the amount of carbon high-frequency induction furnace combustion infrared absorption method
--- Part 15. arsenic, antimony, bismuth contents - Hydride Generation - Atomic Fluorescence Spectrometry
--- Part 16. Determination of DC arc atomic arsenic, cadmium, copper, zinc, lead, bismuth, tin, antimony, silicon, manganese, iron, nickel, aluminum, magnesium content of the emitted light Spectroscopy
--- Part 17. aluminum, manganese, nickel, copper, zinc, cadmium, tin, antimony, lead, bismuth content - Inductively Coupled Plasma Mass Spectrometry
--- Part 18. Determination of sodium content by flame atomic absorption spectrometry
--- Part 19. calcium, magnesium, manganese, iron, cadmium, zinc content - Inductively coupled plasma atomic emission spectrometry
--- Part 20. Determination of oxygen content - Impulse - infrared absorption method this section YS/T 281 - Part 1.
This section drafted in accordance with GB/T 1.1-2009 given rules.
The partial replacement of YS/T 281.1-1994 "Methods for chemical analysis of cobalt sulfosalicylic acid spectrophotometric determination of iron content." versus YS/T 281.1-1994 compared, this section there are major changes as follows.
--- Text format has been modified;
--- Supplementary terms of quality assurance and control, increasing the repeatability limit and reproducibility limit;
--- Complement the test reporting requirements.
The non-ferrous metal part by the National Standardization Technical Committee (SAC/TC243) and focal points.
1 Scope
This section YS/T 281 specifies the method for determination of cobalt in iron content.
This section applies to the determination of iron content in cobalt. Measurement range. 0.00080% to 0.70%.
2 Method summary
Sample dissolved in nitric acid, hydrochloric acid solution at about 7mol L /, 4-methyl-2-pentanone and isoamyl acetate mixed solvent extraction of iron Cobalt separation, then back extracted with water, ammonia solution at pH8.5 ~ 11, the iron (III) with sulfosalicylic acid to form a stable yellow complex 420nm wavelength spectrophotometer measured absorbance.
3 Reagents
Unless otherwise specified, the reagents were analytical reagent solution preparation and analysis are secondary distilled water or equivalent purity test Room with water.
3.1 hydrochloric acid (rho = 1.19g/mL), pure class distinctions.
3.2 nitric acid (rho = 1.42g/mL), pure class distinctions.
3.3 sulfate (rho = 1.84g/mL).
3.4 ammonium hydroxide (rho = 0.90g/mL).
3.5 4-methyl-2-pentanone.
3.6 isoamyl acetate.
3.7 hydrochloride (32).
3.8 nitric acid (32).
3.9 sulfosalicylic acid solution (100g/L).
3.10 mixed extracting agent. 4-Methyl-2-pentanone (3.5) and isoamyl acetate (3.6) are mixed in equal volumes.
3.11 iron standard stock solution. Weigh 0.2859g ferric oxide (wFe2O3 > 99.98%), placed in 200mL beaker, add 15mL hydrochloric acid (3.1), cover sheet pan, dissolve totally cryogenic cooling, the solution is transferred 1000mL volumetric flask with water to volume, and mix.
This solution 1mL containing 200µg iron.
3.12 Iron standard solution. Pipette 10.00mL iron standard stock solution (3.11) in 100mL volumetric flask, dilute to the mark, mix uniform. This solution 1mL containing 20µg iron.
4 Instrument
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 5 pages — is available in the English PDF.
How to Download YS/T 281.1-2011
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
YS/T 281.10-2011 — Methods for chemical analysis of cobalt. Part 10: Determination of nickel content. Flame atomic absorption spectrometry
YS/T 281.11-2011 — Methods for chemical analysis of cobalt. Part 11: Determination of copper and manganese contents. Flame atomic absorption spectrometry
YS/T 281.12-2011 — Methods for chemical analysis of cobalt. Part 12: Determination of arsenic, antimony, bismuth, tin and lead content. Electrothermal atomic absorption spectrometry
Secure payment via Stripe
Payments accepted
YS/T 281.1-2011
$164.00