Valid

YS/T 276.6-2011Methods for chemical analysis of indium. Part 6: Determination of copper, cadmium and zinc content. Flame atomic absorption spectrometry (English PDF)

铟化学分析方法 第6部分:铜、镉、锌量的测定火焰原子吸收光谱法

Preview PDF

This is a limited preview

Buy now to download the full PDF (7 pages)

Need quotation for your management?

Get a formal quotation for YS/T 276.6-2011 in 30 minutes.

Issued by

Ministry of Industry and Information Technology

Level / Type

National · Recommended

Issue date

December 20, 2011

Implementation date

July 1, 2012

Scope

YS/T 276.6-2011 is the English-translated version of 铟化学分析方法 第6部分:铜、镉、锌量的测定火焰原子吸收光谱法.

YS/T 276.6-2011 — This section YS/T 276 provides for copper indium, cadmium and zinc content. This section applies to copper, cadmium, zinc contents in indium. Measurement range Cu0.00030% ~ 0.200%, Cd0.00030% ~ 0.200%, Zn0.00030% ~ 0.100%.

Found what you need?

Document preview — YS/T 276.6-2011

National Standard of the People's Republic of China

ICS
77.120.99
Classification
H 13
Replacing
YS/T 276.5-1994

Issued by: Ministry of Industry and Information Technology

Contents

  • Foreword
  • 1 Scope
  • 2 Principle of the method
  • 3 Reagents
  • 3.6 Standard solution

Foreword

YS/T 276 "indium chemical analysis methods," including a total of 11 parts.

--- Part 1. Determination of arsenic content by hydride generation - atomic fluorescence spectrometry;

--- Part 2. Determination of tin content Phenylfluorone - bromo cetyl trimethylamine spectrophotometry;

--- Part 3. Determination of the amount of thallium methyl green spectrophotometry;

--- Part 4. Determination of the amount of chrome aluminum Azure S Spectrophotometry;

--- Part 5. Determination of iron content of 1. electrothermal atomic absorption spectrometry Method 2. Flame atomic absorption spectrometry;

--- Part 6. copper, cadmium, zinc content - Flame atomic absorption spectrometry;

--- Part 7. Determination of lead content by flame atomic absorption spectrometry;

--- Part 8. Determination of bismuth content 1. Hydride Generation - Atomic Fluorescence Spectrometry Method 2. Flame atomic absorption spectrometry;

--- Part 9. Determination of the amount of indium Na2EDTA titration;

--- Part 10. bismuth, aluminum, lead, iron, copper, cadmium, tin, thallium content - Inductively coupled plasma atomic emission spectrometry;

--- Part 11. arsenic, aluminum, lead, iron, copper, cadmium, tin, thallium, zinc, bismuth content - Inductively Coupled Plasma Mass Spectrometry.

This section is in accordance with the rules of GB/T 1.1 gives drafted.

This section YS/T Part 6 276.

The partial replacement of YS/T 276.5-1994 "Methods for chemical analysis of indium atomic absorption spectrophotometry of copper, iron, zinc, cadmium content" in the Determination of copper, zinc portion, the amount of cadmium, compared with YS/T 276.5-1994, have the following main changes.

--- The determination of iron in a single listed, an increase of electrothermal atomic absorption spectrometry;

--- Copper measuring range extended from 0.0003% ~ 0.0015-.00030% ~ 0.200%;

Cadmium measurement range extended from 0.0010% ~ 0.025 to 0.00030% - 0.200%;

Zinc measurement range extended from less than 0.0010% from 0.0025 to 0.00030 percent to 0.100%;

--- Complements the precision, quality assurance and control provisions;

--- Complements the "test report" requirement.

The non-ferrous metal part by the National Standardization Technical Committee (SAC/TC243) centralized.

1 Scope

This section YS/T 276 provides for copper indium, cadmium and zinc content.

This section applies to copper, cadmium, zinc contents in indium. Measurement range Cu0.00030% ~ 0.200%, Cd0.00030% ~ 0.200%, Zn0.00030% ~ 0.100%.

2 Principle of the method

Sample decomposition with hydrochloric acid. In hydrochloric acid medium, atomic absorption spectrometer wavelength 324.7nm, 228.8nm, 213.9nm place, respectively Measurement of copper, cadmium, zinc absorbance.

3 Reagents

Unless otherwise indicated, used in the analysis confirmed only for the gifted class pure reagents and distilled or deionized water or equivalent purity.

3.1 hydrochloride (rho1.19g/mL).

Nitrate 3.2 (rho1.42g/mL).

3.3 hydrochloric acid solution (119).

3.4 nitric acid solution (11).

3.5 nitric acid solution (119).

3.6 Standard solution

3.6.1 copper standard stock solution. Weigh 1.0000g copper (w>=99.99%), placed in 250mL beaker, add 15mL of nitric acid (3.2), low dissolved by heating, boiling rid of nitrogen oxides, remove cooling. Moved into 1000mL volumetric flask, nitric acid (3.5) diluted to Volume, and mix. 1mL solution containing 1mg of copper.

3.6.2 cadmium standard stock solution. Weigh 1.0000g metal cadmium (w>=99.99%) in 250mL beaker, add 15mL of nitric acid solution Solution (3.4), low dissolved by heating, boiling rid of nitrogen oxides, remove cooling. Moved into 1000mL volumetric flask, nitric acid (3.5) diluted to the mark, and mix. This solution 1mL 1mg containing cadmium.

3.6.3 standard zinc stock solution. Weigh 1.0000g zinc metal (w>=99.99%) in 250mL beaker, add 15mL of nitric acid solution Solution (3.4), low dissolved by heating, boiling rid of nitrogen oxides, remove cooling. Moved into 1000mL volumetric flask, nitric acid (3.5) diluted to the mark, and mix. 1mL solution containing 1mg zinc.

3.6.4 copper, cadmium, zinc mixed standard solution. Pipette respectively 5.00mL copper standard stock solution (3.6.1), 5.00mL cadmium standard storage solution Solution (3.6.2), 5.00mL standard zinc stock solution (3.6.3) in 1000mL volumetric flask, hydrochloric acid solution (3.3) diluted to the mark, mix uniform. This solution 1mL copper, cadmium and zinc are 5µg.

3.6.5 copper, cadmium, zinc mixed standard solution. Pipette respectively 5.00mL copper standard stock solution (3.6.1), 5.00mL cadmium standard storage solution

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 7 pages — is available in the English PDF.

How to Download YS/T 276.6-2011

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
7 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

YS/T 276.6-2011