YS/T 276.11-2011Methods for chemical analysis of indium. Part 11: Determination of arsenic, aluminium, lead, iron, copper, cadmium, tin, thallium, zinc and bismuth content. Inductively coupled plasma mass spectrometry (English PDF)
铟化学分析方法 第11部分:砷、铝、铅、铁、铜、镉、锡、铊、锌、铋量的测定电感耦合等离子体质谱法
This is a limited preview
Buy now to download the full PDF (7 pages)
Need quotation for your management?
Get a formal quotation for YS/T 276.11-2011 in 30 minutes.
Issued by
Ministry of Industry and Information Technology
Level / Type
National · Recommended
Issue date
December 20, 2011
Implementation date
July 1, 2012
Scope
YS/T 276.11-2011 is the English-translated version of 铟化学分析方法 第11部分:砷、铝、铅、铁、铜、镉、锡、铊、锌、铋量的测定电感耦合等离子体质谱法.
YS/T 276.11-2011 — This section YS/T 276 provides for arsenic, aluminum, copper, cadmium, iron, lead, thallium, tin, zinc, bismuth determination of indium. This section applies to the determination of indium arsenic, aluminum, copper, cadmium, iron, lead, thallium, tin, zinc, bismuth content was measured in the range of 0.00010% ~ 0.0050%.
Found what you need?
Document preview — YS/T 276.11-2011
National Standard of the People's Republic of China
- ICS
- 77.120.99
- Classification
- H 13
Issued by: Ministry of Industry and Information Technology
Contents
- Foreword
- 1 Scope
- 2 Principle of the method
- 3 Reagents
- 3.4 Hydrochloric acid (rho = 1.19g/mL), MOS level
- 3.7 Pure water (resistance > 18Mohm · cm)
Foreword
YS/T 276 "indium chemical analysis methods," including a total of 11 parts.
--- Part 1. Determination of arsenic content by hydride generation - atomic fluorescence spectrometry;
--- Part 2. Determination of tin content Phenylfluorone - bromo cetyl trimethylamine spectrophotometry;
--- Part 3. Determination of the amount of thallium methyl green spectrophotometry;
--- Part 4. Determination of the amount of chrome aluminum Azure S Spectrophotometry;
--- Part 5. Determination of iron content of 1. electrothermal atomic absorption spectrometry Method 2. Flame atomic absorption spectrometry;
--- Part 6. copper, cadmium, zinc content - Flame atomic absorption spectrometry;
--- Part 7. Determination of lead content by flame atomic absorption spectrometry;
--- Part 8. Determination of bismuth content 1. Hydride Generation - Atomic Fluorescence Spectrometry Method 2. Flame atomic absorption spectrometry;
--- Part 9. Determination of the amount of indium Na2EDTA titration;
--- Part 10. bismuth, aluminum, lead, iron, copper, cadmium, tin, thallium content - Inductively coupled plasma atomic emission spectrometry;
--- Part 11. arsenic, aluminum, lead, iron, copper, cadmium, tin, thallium, zinc, bismuth content - Inductively Coupled Plasma Mass Spectrometry.
This section drafted in accordance with the rules of GB/T 1.1 is given.
This section YS/T Part 11 276.
The non-ferrous metal part by the National Standardization Technical Committee (SAC/TC243) centralized.
1 Scope
This section YS/T 276 provides for arsenic, aluminum, copper, cadmium, iron, lead, thallium, tin, zinc, bismuth determination of indium.
This section applies to the determination of indium arsenic, aluminum, copper, cadmium, iron, lead, thallium, tin, zinc, bismuth content was measured in the range of 0.00010% ~ 0.0050%.
2 Principle of the method
The sample is dissolved in nitric acid in acid medium, using ICP-MS- standard addition calibration and the use of added scandium, rhodium, rhenium mixed internal standard method of measurement Given indium arsenic, aluminum, copper, cadmium, iron, lead, thallium, tin, zinc, bismuth content.
3 Reagents
Unless otherwise indicated in the analysis using recognized as excellent pure reagents and distilled or deionized water or equivalent purity. Laboratory are fully cleaned thoroughly soaked with water containers with a solution of nitric acid (119).
3.1 nitric acid (rho = 1.42g/mL), MOS level.
3.2 nitric acid solution (11).
3.3 nitric acid solution (19).
3.4 Hydrochloric acid (rho = 1.19g/mL), MOS level
3.5 hydrochloric acid solution (11).
3.6 hydrochloric acid solution (14).
3.7 Pure water (resistance > 18Mohm · cm)
3.8 standard aluminum stock solution. Weigh 1.0000g aluminum [w>=99.99%], placed in 300mL beaker, add 20mL of hydrochloric acid (3.4), drop Add 1mL ~ 2mL nitric acid (3.1), low dissolved and transferred to 1000mL volumetric flask, was added 80mL of hydrochloric acid (3.4) was diluted with water to the mark with Degree, and mix. 1mL solution containing 1mg aluminum.
3.9 iron standard stock solution. Weigh 1.0000g metal wire [w>=99.99%], placed in 150mL beaker, add 150mL nitrate Acid solution (3.3), dissolved by heating, cooling, transferred to 1000mL volumetric flask, dilute with water to volume, and mix. This solution containing 1mL 1mg iron.
3.10 copper standard stock solution. Weigh 1.0000g copper [w>=99.99%], placed in 300mL beaker, add 10mL nitric acid solution (3.3), low dissolved nitrogen oxide removing the heating, cooling is removed and transferred to 1000mL volumetric flask, nitric acid solution was added 100mL (3.3), dilute to the mark and mix. 1mL solution containing 1mg of copper.
3.11 standard zinc stock solution. Weigh 1.0000g zinc [w>=99.99%], placed in 150mL beaker, add 50mL of nitric acid
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 7 pages — is available in the English PDF.
How to Download YS/T 276.11-2011
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
YS/T 276.1-2011 — Methods for chemical analysis of indium. Part 1: Determination of arsenic content. Hydride generation-atomic fluorescence spectrometry
YS/T 276.10-2011 — Methods for chemical analysis of indium. Part 10: Determination of bismuth, aluminium, lead, iron, copper, cadmium, tin and thallium content. Inductively coupled plasma atomic emission spectrometry
YS/T 276.2-2011 — Methods for chemical analysis of indium. Part 2: Determination of tin content. Phenylfluorone-cetyltrimethyl ammonium bromide spectrophotometry
Secure payment via Stripe
Payments accepted
YS/T 276.11-2011
$165.00