Valid

YS/T 227.8-2010Methods for chemical analysis of bismuth. Part 8: Determination of magnesium and sodium content. Flame atomic absorption spectrometry (English PDF)

碲化学分析方法 第8部分镁、钠量的测定 火焰原子吸收光谱法

Preview PDF

This is a limited preview

Buy now to download the full PDF (4 pages)

Need quotation for your management?

Get a formal quotation for YS/T 227.8-2010 in 30 minutes.

Issued by

Ministry of Industry and Information Technology

Level / Type

National · Recommended

Issue date

November 13, 2010

Implementation date

March 1, 2011

Scope

YS/T 227.8-2010 is the English-translated version of 碲化学分析方法 第8部分镁、钠量的测定 火焰原子吸收光谱法.

YS/T 227.8-2010 — YS/T of the provisions of the section 227 determination of tellurium in the amount of magnesium and sodium content. This section applies to the determination of tellurium in the amount of magnesium and sodium content. Measuring range. Mg. 0.0005% ~ 0.0030%; Na. 0.0020% ~ 0.0070%.

Found what you need?

Document preview — YS/T 227.8-2010

National Standard of the People's Republic of China

ICS
77.120.99
Classification
H 13
Replacing
YS/T 227.8-1994

Issued by: Ministry of Industry and Information Technology

Contents

  • Foreword
  • 1 Scope
  • 2 Principle of the method
  • 3 Reagents
  • 4 Instrument

Foreword

YS/T 227 "tellurium chemical analysis methods," a total of 12 parts.

--- Part 1. Determination of bismuth content hydride generation - atomic fluorescence spectrometry;

--- Part 2. Determination of aluminum content Chromazurol S- bromo cylpyridinium micellar solubilization spectrophotometry;

--- Part 3. Determination of lead content by flame atomic absorption spectrometry;

--- Part 4. Determination of iron content - Phenanthroline spectrophotometric method;

--- Part 5. determination of selenium content of 2,3-diaminonaphthalene spectrophotometry;

--- Part 6. Determination of copper content of solid-liquid separation - flame atomic absorption spectrometry;

--- Part 7. Determination of sulfur content by inductively coupled plasma atomic emission spectrometry;

--- Part 8. magnesium, sodium content - Flame atomic absorption spectrometry;

--- Part 9. Determination of tellurium content of potassium dichromate - ammonium ferrous sulfate volumetric method;

--- Part 10. Determination of arsenic content by hydride generation - atomic fluorescence spectrometry;

--- Part 11. Determination of silicon content of n-butanol silicon molybdenum blue spectrophotometric method;

--- Part 12. bismuth, aluminum, lead, iron, selenium, copper, magnesium, sodium, arsenic content - Inductively coupled plasma atomic emission spectrometry.

This section 8.

This section drafted in accordance with GB/T 1.1-2009 given rules.

The partial replacement of YS/T 227.8-1994 "tellurium magnesium, sodium content was measured (atomic absorption spectrometry)." And YS/T 227.8-1994 Compared to the main part of the following changes.

--- Measurement range, Mg from 0.001% to 0.002% by the expansion of 0.0005% ~ 0.0030%, Na 0.006% from 0.003% Extended 0.0020% 0.0070%;

--- Complements the precision, quality assurance and control provisions;

--- Complements the "test report" requirement.

The non-ferrous metal part by the National Standardization Technical Committee (SAC/TC243) centralized.

This section is responsible for drafting unit. Zhuzhou Smelter Group Co., Ltd.

It participated in the drafting of this section. Jiangxi Copper Corporation, Sichuan Apollo Solar Energy Technology Co., Ltd.

1 Scope

YS/T of the provisions of the section 227 determination of tellurium in the amount of magnesium and sodium content.

This section applies to the determination of tellurium in the amount of magnesium and sodium content. Measuring range. Mg. 0.0005% ~ 0.0030%; Na. 0.0020% ~ 0.0070%.

2 Principle of the method

Sample with nitric acid and hydrochloric acid dissolved, strontium salt eliminate the interference of coexisting elements in dilute nitric acid and hydrochloric acid medium, using air - acetylene fire Flame atomic absorption spectrometer wavelength 285.2nm, 589.0nm measured magnesium, sodium absorbance to a standard curve method to calculate the amount of magnesium, sodium content.

3 Reagents

Unless otherwise indicated in the analysis using only recognized as an analytical reagent and water.

Nitrate 3.1 (rho1.40g/mL), ultra-pure.

3.2 hydrochloride (rho1.19g/mL), ultra-pure.

3.3 nitric acid (11).

3.4 nitric acid (110).

3.5 hydrochloride (11).

3.6 Strontium nitrate solution (100g/L).

3.7 Magnesium standard stock solution. Weigh 0.1000g of magnesium (>=99.95%), placed in 100mL beaker, add 20mL of nitric acid (3.4), Was heated until complete dissolution, boiling rid of nitrogen oxides, is removed, cooled and transferred to 1000mL volumetric flask, dilute to the mark with water and mix.

This solution 1mL containing 100µg magnesium.

3.8 Sodium standard stock solution. Weigh 0.2545g pre-drying at 120 °C reference reagent sodium chloride, placed 100mL beaker, add A small amount of water dissolved and transferred to 1000mL volumetric flask, dilute with water to volume, and mix. This solution 1mL containing 100µg sodium.

3.9 Magnesium standard solution. Pipette 10.00mL magnesium standard stock solution (3.7) in 200mL volumetric flask, dilute with water to volume, and mix.

This solution 1mL containing 5µg magnesium.

3.10 Sodium standard solution. Pipette 12.00mL sodium standard stock solution (3.8) in 100mL volumetric flask, dilute with water to volume, and mix.

This solution 1mL containing 12µg sodium.

4 Instrument

Atomic absorption spectrometer, with magnesium, sodium hollow cathode lamp.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 4 pages — is available in the English PDF.

How to Download YS/T 227.8-2010

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
4 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

YS/T 227.8-2010

$85.00