Valid

YS/T 227.1-2010Methods for chemical analysis of tellurium. Part 1: Determination of bismuth content. Hydride generation-atomic fluorescence absorption spectrometry (English PDF)

碲化学分析方法 第1部分:铋量的测定氢化物发生-原子荧光光谱法

Preview PDF

This is a limited preview

Buy now to download the full PDF (4 pages)

Need quotation for your management?

Get a formal quotation for YS/T 227.1-2010 in 30 minutes.

Issued by

Ministry of Industry and Information Technology

Level / Type

National · Recommended

Issue date

November 22, 2010

Implementation date

March 1, 2011

Scope

YS/T 227.1-2010 is the English-translated version of 碲化学分析方法 第1部分:铋量的测定氢化物发生-原子荧光光谱法.

YS/T 227.1-2010 — YS/T of the provisions of the section 227 determination of tellurium content of bismuth. This section applies to the determination of bismuth tellurium content. Measurement range. 0.0001% to 0.0025%.

Found what you need?

Document preview — YS/T 227.1-2010

National Standard of the People's Republic of China

ICS
77.120.99
Classification
H 13
Replacing
YS/T 227.1-1994

Issued by: Ministry of Industry and Information Technology

Contents

  • Foreword
  • 1 Scope
  • 2 Principle of the method
  • 3 Reagents
  • 4 Instrument

Foreword

YS/T 227 "tellurium chemical analysis methods," a total of 12 parts.

--- Part 1. Determination of bismuth content hydride generation - atomic fluorescence spectrometry;

--- Part 2. Determination of aluminum content Chromazurol S- bromo cylpyridinium micellar solubilization spectrophotometry;

--- Part 3. Determination of lead content by flame atomic absorption spectrometry;

--- Part 4. Determination of iron content - Phenanthroline spectrophotometric method;

--- Part 5. determination of selenium content of 2,3-diaminonaphthalene spectrophotometry;

--- Part 6. Determination of copper content of solid-liquid separation - flame atomic absorption spectrometry;

--- Part 7. Determination of sulfur content by inductively coupled plasma atomic emission spectrometry;

--- Part 8. magnesium, sodium content - Flame atomic absorption spectrometry;

--- Part 9. Determination of tellurium content of potassium dichromate - ammonium ferrous sulfate volumetric method;

--- Part 10. Determination of arsenic content by hydride generation - atomic fluorescence spectrometry;

--- Part 11. Determination of silicon content of n-butanol silicon molybdenum blue spectrophotometric method;

--- Part 12. bismuth, aluminum, lead, iron, selenium, copper, magnesium, sodium, arsenic content - Inductively coupled plasma atomic emission spectrometry.

This is Part 1.

This section drafted in accordance with GB/T 1.1-2009 given rules.

"Determination of the amount of bismuth telluride (potassium iodide, dimethyl brucine photometric method)" in this section instead of YS/T 227.1-1994. versus YS/T 227.1-1994 compared, this section has the following changes.

--- Changed the measurement method using hydride generation - atomic fluorescence spectrometry;

--- Expands the measurement range, modify 0.0001% 0.0025%;

--- Complements the precision, quality assurance and control provisions;

--- Complements the "test report" requirement.

The non-ferrous metal part by the National Standardization Technical Committee (SAC/TC243) centralized.

This section is responsible for drafting unit. Zhuzhou Smelter Group Co., Ltd.

This section is drafted. Beijing General Research Institute of Mining and Metallurgy.

It participated in the drafting of this section. Zhuzhou Smelter Group Co., Ltd., Liaoning Entry Inspection and Quarantine Bureau.

1 Scope

YS/T of the provisions of the section 227 determination of tellurium content of bismuth.

This section applies to the determination of bismuth tellurium content. Measurement range. 0.0001% to 0.0025%.

2 Principle of the method

Samples with hydrochloric acid, nitric acid dissolved in hydrochloric acid medium, sulfite reduction tellurite to tellurium acid precipitation to remove the matrix, using a hydride - atomic fluorescence Spectrophotometer Determination of bismuth content.

3 Reagents

Unless otherwise indicated in the analysis using only recognized as analytical grade reagents and distilled or deionized water or equivalent purity.

3.1 nitrate (rho1.43g/mL), pure class distinctions.

3.2 hydrochloric acid (rho1.19g/mL), pure class distinctions.

3.3 hydrochloride (11).

3.4 hydrochloric acid, 20% (volume fraction).

3.5 sulfurous acid (sulfur dioxide containing not less than 6.0%).

3.6 ascorbic acid solution (100g/L).

3.7 solution of potassium borohydride (10g/L). Weigh 10g of potassium borohydride dissolved in 1000mL potassium hydroxide solution (5g/L), a shake. Active Now equipped.

3.8 bismuth standard stock solution. Weigh 0.1000g bismuth (>=99.95%), plus 10mL of nitric acid (11), low temperature heating is completely dissolved, add Into 50mL of nitric acid (3.1), cooled and transferred to 1000mL volumetric flask with water to volume, and mix. This solution 1mL containing 0.10mg bismuth.

3.9 Bismuth standard solution. Pipette 2.00mL bismuth standard stock solution (3.8) in 200mL volumetric flask, dilute to the mark with hydrochloric acid (14), shake uniform. This solution 1mL containing 1.0µg bismuth.

4 Instrument

Atomic fluorescence spectrometer, with high-intensity hollow cathode lamp bismuth.

Under optimum working conditions, where the index can be used to achieve the following.

--- Detection limit. not more than 2 × 10-9g/mL.

--- Precision. measuring the fluorescence intensity of 10 times with a bismuth standard solution 0.02µg/mL, which should not exceed the standard deviation of the mean fluorescence intensity 5.0%.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 4 pages — is available in the English PDF.

How to Download YS/T 227.1-2010

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
4 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

YS/T 227.1-2010

$90.00