YS/T 227.6-2010Methods for chemical analysis of tellurium. Part 6: Determination of copper content. Solid-liquid separate-flame atomic absorption spectrophotometry (English PDF)
碲化学分析方法 第6部分:铜量的测定固液分离-火焰原子吸收光谱法
This is a limited preview
Buy now to download the full PDF (4 pages)
Need quotation for your management?
Get a formal quotation for YS/T 227.6-2010 in 30 minutes.
Issued by
Ministry of Industry and Information Technology
Level / Type
National · Recommended
Issue date
November 22, 2010
Implementation date
March 1, 2011
Scope
YS/T 227.6-2010 is the English-translated version of 碲化学分析方法 第6部分:铜量的测定固液分离-火焰原子吸收光谱法.
YS/T 227.6-2010 — This section YS/T 227 specifies the method for determination of tellurium copper content. This section applies to the determination of copper content in tellurium. Measurement range. 0.0004% to 0.0060%.
Found what you need?
Document preview — YS/T 227.6-2010
National Standard of the People's Republic of China
- ICS
- 77.120.99
- Classification
- H 13
- Replacing
- YS/T 227.6-1994
Issued by: Ministry of Industry and Information Technology
Contents
- Foreword
- 1 Scope
- 2 Principle of the method
- 3 Reagents
- 4 Instrument
Foreword
YS/T 227 "tellurium chemical analysis methods," a total of 12 parts.
--- Part 1. Determination of bismuth content hydride generation - atomic fluorescence spectrometry;
--- Part 2. Determination of aluminum content Chromazurol S- bromo cylpyridinium micellar solubilization spectrophotometry;
--- Part 3. Determination of lead content by flame atomic absorption spectrometry;
--- Part 4. Determination of iron content - Phenanthroline spectrophotometric method;
--- Part 5. determination of selenium content of 2,3-diaminonaphthalene spectrophotometry;
--- Part 6. Determination of copper content of solid-liquid separation - flame atomic absorption spectrometry;
--- Part 7. Determination of sulfur content by inductively coupled plasma atomic emission spectrometry;
--- Part 8. magnesium, sodium content - Flame atomic absorption spectrometry;
--- Part 9. Determination of tellurium content of potassium dichromate - ammonium ferrous sulfate volumetric method;
--- Part 10. Determination of arsenic content by hydride generation - atomic fluorescence spectrometry;
--- Part 11. Determination of silicon content of n-butanol silicon molybdenum blue spectrophotometric method;
--- Part 12. bismuth, aluminum, lead, iron, selenium, copper, magnesium, sodium, arsenic content - Inductively coupled plasma atomic emission spectrometry.
Part is divided into 6 sections.
This section drafted in accordance with GB/T 1.1-2009 given rules.
The partial replacement of YS/T 227.6-1994 "determination of tellurium in copper content (Neocuproine - chloroform extraction photometric method)." versus YS/T 227.6-1994 compared, this section has the following changes.
--- Changed the measurement method, the use of solid-liquid separation - flame atomic absorption spectrometry;
--- Complements the precision, quality assurance and control provisions;
--- Complements the "test report" requirement.
The non-ferrous metal part by the National Standardization Technical Committee (SAC/TC243) centralized.
This section is responsible for drafting unit. Zhuzhou Smelter Group Co., Ltd.
Participated in the drafting of this section. Beijing Mining Research Institute, Sichuan Apollo Solar Energy Technology Co., Ltd.
1 Scope
This section YS/T 227 specifies the method for determination of tellurium copper content.
This section applies to the determination of copper content in tellurium. Measurement range. 0.0004% to 0.0060%.
2 Principle of the method
Sample dissolved in nitric acid, dilute nitric acid leaching of copper ions and most of the matrix isolation, air - atomic absorption spectrometer wave acetylene flame Long 324.8nm at measuring the absorbance of copper, the standard curve method to calculate the amount of copper.
3 Reagents
Unless otherwise indicated in the analysis using only recognized as analytical grade reagents and distilled or deionized water or equivalent purity.
Nitrate 3.1 (rho1.42g/mL).
3.2 nitric acid (11).
3.3 nitric acid (199).
3.4 copper standard stock solution. Weigh 1.0000g copper (>=99.95%), placed in 200mL beaker, add 15mL of nitric acid (3.2), low-temperature heating to dissolve completely removing nitrogen oxides boil, cooled and transferred to 1000mL volumetric flask, 20mL of nitric acid was added (3.2), dilute to the mark and mix. 1mL solution containing 1mg of copper.
3.5 Copper standard solution. Weigh 5.00mL copper standard stock solution (3.4) in 100mL flask, add 2mL nitric acid (3.2), with Dilute with water to volume, and mix. This solution 1mL containing 50µg copper.
4 Instrument
Atomic absorption spectrometer, with copper hollow cathode lamp.
Under optimum working conditions for those who can reach the following indicators can be used.
--- Characteristic concentration. In line with the measurement of the sample solution matrix solution features copper concentration should be less than 0.025µg/mL;
--- Precision. standard solution with the highest concentration of 10 times the absorbance measurements, the standard deviation should not exceed the average absorbance of 1.0%;
With the lowest concentration of standard solution (not "zero" concentration of the standard) measuring the absorbance of 10 times, the standard deviation should not exceed the maximum 0.5% concentration of the standard average absorbance;
--- Linear curve. The curve is divided into five sections according to concentration, absorbance difference between the absorbance difference between the highest and the lowest segment of the segment Ratio of not less than 0.8.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 4 pages — is available in the English PDF.
How to Download YS/T 227.6-2010
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
YS/T 227.1-2010 — Methods for chemical analysis of tellurium. Part 1: Determination of bismuth content. Hydride generation-atomic fluorescence absorption spectrometry
YS/T 227.10-2010 — Methods for chemical analysis of tellurium. Part 10: Determination of arsenic content. Hedride generation-atomic fluorescence spectrometry
YS/T 227.11-2010 — Mothods for chemical analysis of tellurium. Part 11: Determination silicon content. N-butanol extraction molybdenum blue spectrophotometry
Secure payment via Stripe
Payments accepted
YS/T 227.6-2010
$90.00