YS/T 1120.3-2016Methods for chemical analysis of gold-tin alloys. Part 3: Determination of iron, copper, silver, lead, palladium, cadmium, zinc content. Inductively coupled plasma atomic emission spectrometry (English PDF)
金锡合金化学分析方法 第3部分:铁、铜、银、铅、钯、镉、锌量的测定 电感耦合等离子体原子发射光谱法
This is a limited preview
Buy now to download the full PDF (5 pages)
Need quotation for your management?
Get a formal quotation for YS/T 1120.3-2016 in 30 minutes.
Issued by
Ministry of Industry and Information Technology
Level / Type
National · Recommended
Issue date
July 11, 2016
Implementation date
January 1, 2017
Scope
YS/T 1120.3-2016 is the English-translated version of 金锡合金化学分析方法 第3部分:铁、铜、银、铅、钯、镉、锌量的测定 电感耦合等离子体原子发射光谱法.
YS/T 1120.3-2016 — This part of YS/T 1120 specifies the determination of iron, copper, silver, lead, palladium, cadmium and zinc in gold and tin alloys. This part is applicable to the determination of iron, copper, silver, lead, palladium, cadmium and zinc in gold and tin alloy.
The measurement range is shown in Table 1. Table 1 Measurement range Element determination range /% element determination range /% Iron 0.001 ~ 0.1 Copper 0.001 ~ 0.1 Silver 0.001 to 0.1 Lead 0.001 ~ 0.1 Palladium 0.001 to 0.1 Cadmium 0.001 ~ 0.1 Zinc 0.001 to 0.1 - -
Found what you need?
Document preview — YS/T 1120.3-2016
National Standard of the People's Republic of China
- ICS
- 77.120.99
- Classification
- H 68
Issued by: Ministry of Industry and Information Technology
Contents
- Foreword
- 1 Scope
- 2 Method summary
- 3 Reagents and materials
Foreword
YS/T 1120 "gold and tin alloy chemical analysis method" is divided into the following three parts;
- Part 1. Determination of gold quantity - Fire test method;
- Part 2. Determination of tin content - Fluoride precipitation EDTA complexometric titration;
Part 3. Determination of iron, copper, silver, lead, palladium, cadmium and zinc - Inductively coupled plasma atomic emission spectrometric method.
This section is part 3 of YS/T 1120.
This part is drafted in accordance with the rules given in GB/T 1.1-2009.
This part of the National Nonferrous Metals Standardization Technical Committee (SAC/TC243) proposed and centralized.
This part of the main drafting unit. your research and testing technology (Yunnan) Co., Ltd., your research Platinum Co., Ltd., China Nonferrous Metals Industry Standard Measurement Quality Institute.
This part participates in the drafting unit. Guangzhou Nonferrous Metals Research Institute, Beijing Institute of Nonferrous Metals and Rare Earth Application, Jiangxi Han's Precious Metals Co., Ltd., Fujian Zijin Mining and Metallurgy Testing Technology Co., Ltd., Anhui Tongling colored rare precious metals branch.
This part of the main drafters. He Jiao, Xiang Lei, Fang Haiyan, Li Guangli, Sun Qi, Wang Jin, Wang Fang, Wang Lingfeng, Yu Jinsheng, Gong Changhe, Chen Yan, Yu Fengshan, Sun Baofei, Fan Shuhui, Zhi Fuguo.
Metallographic analysis of gold alloy Part 3. determination of iron, copper, silver, lead, palladium, cadmium and zinc Inductively coupled plasma atomic emission spectrometry
1 Scope
This part of YS/T 1120 specifies the determination of iron, copper, silver, lead, palladium, cadmium and zinc in gold and tin alloys.
This part is applicable to the determination of iron, copper, silver, lead, palladium, cadmium and zinc in gold and tin alloy. The measurement range is shown in Table 1.
Table 1 Measurement range
Element determination range /% element determination range /% Iron 0.001 ~ 0.1 Copper 0.001 ~ 0.1 Silver 0.001 to 0.1 Lead 0.001 ~ 0.1 Palladium 0.001 to 0.1 Cadmium 0.001 ~ 0.1 Zinc 0.001 to 0.1 - -
2 Method summary
The samples were determined by hydrochloric acid, nitric acid, and inductively coupled plasma atomic emission spectrometry. The contents of iron, copper, silver, lead, palladium, cadmium and zinc were calculated.
Volume fraction.
3 Reagents and materials
The laboratory uses water as a water.
3.1 nitric acid (rho1.42g/mL), excellent grade pure.
3.2 hydrochloric acid (rho1.19g/mL), excellent grade pure.
3.3 Hydrochloric acid (1 4).
3.4 iron standard storage solution. Weigh 0.1000g metal iron powder (mass fraction >= 99.99%), placed in 100mL quartz beaker, add 3mL hydrochloric acid (3.2), dissolved in low temperature heating completely, into the 100mL volumetric flask, add 10mL hydrochloric acid (3.2), diluted with water to the mark. mix uniform. This solution contains 1 mL of 1.0 mg of iron.
3.5 copper standard storage solution. Weigh 0.1000g metal copper (mass fraction >= 99.99%), placed in 100mL quartz beaker, add 2mL nitric acid (3.1), dissolved in low temperature heating completely, into the 100mL volumetric flask, add 10mL hydrochloric acid (3.2), diluted with water to the mark.
Mix well. This solution contains 1 mL of 1.0 mg of copper.
3.6 silver standard storage solution. Weigh 0.1000g metal silver (mass fraction >= 99.99%), placed in 100mL quartz beaker, add 2mL nitric acid (3.1), dissolved in low temperature heating completely, into the 100mL volumetric flask, add 70mL hydrochloric acid (3.2), diluted with water to the mark.
Mix well. This solution contains 1 mL of 1.0 mg of silver.
3.7 lead standard storage solution. Weigh 0.1000g metal lead (mass fraction >= 99.99%), placed in 100mL quartz beaker, add 3mL nitric acid (3.1), dissolved in low temperature heating completely, into the 100mL volumetric flask, add 10mL hydrochloric acid (3.2), diluted with water to the mark.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 5 pages — is available in the English PDF.
How to Download YS/T 1120.3-2016
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
YS/T 1120.1-2016 — Method for chemical analysis of gold-tin alloys--Part 1: Determination of gold content--Fire assay gravimetric method
YS/T 1120.2-2016 — Method for chemical analysis of gold-tin alloys--Part 2: Determination of tin content--Complexometric titration using fluoride releasing EDTA
YS/T 1115.10-2026 — Chemical analysis methods of copper, lead and zinc ores and tailings - Part 10: Determination of gold, silver, molybdenum, arsenic, tungsten, bismuth, gallium, indium, thallium, selenium, tellurium and germanium contents - Inductively coupled plasma mass spectrometry
Secure payment via Stripe
Payments accepted
YS/T 1120.3-2016
$90.00