Scope

YS/T 1075.6-2015 is the English-translated version of 钒铝、钼铝中间合金化学分析方法 第6部分:碳量的测定 高频燃烧-红外吸收法.

YS/T 1075.6-2015 — YS/T 1075 This section provides the vanadium aluminum, master alloy of molybdenum determination of carbon content. This section applies to aluminum vanadium, molybdenum determination of carbon content of aluminum master alloy. Measurement range. 0.005% to 0.60%.

Found what you need?

Document preview — YS/T 1075.6-2015

National Standard of the People's Republic of China

ICS
77.120.99
Classification
H 14

Issued by: Ministry of Industry and Information Technology

Contents

  • Foreword
  • 1 Scope
  • 2 Method summary
  • 3 Reagents and materials
  • 4 Instrument
  • 5 Sample
  • 6 Step, Analysis
  • 6.1 Warm up
  • 6.2 Instrument Leak

Foreword

YS/T 1075 "aluminum vanadium, molybdenum intermediate aluminum alloy chemical analysis method" including a total of 8 sections.

--- Part 1. Determination of iron content - 1,10-phenanthroline spectrophotometry;

--- Part 2. Determination of molybdenum content of lead molybdate gravimetric method;

--- Part 3. Determination of silicon content - Molybdenum blue spectrophotometric method;

--- Part 4. vanadium content - Inductively coupled plasma atomic emission spectrometry and ferrous ammonium sulfate titration;

--- Part 5. Determination of aluminum content EDTA titration;

--- Part 6. Determination of carbon content in the high-frequency combustion - infrared absorption method;

--- Part 7. Determination of the amount of oxygen in the inert gas fusion - infrared method;

--- Part 8. molybdenum, aluminum X- determining the amount of fluorescence spectroscopy.

This section YS/T 1075 Part 6.

This section drafted in accordance with GB/T 1.1-2009 given rules.

The non-ferrous metal part by the National Standardization Technical Committee (SAC/TC243) and focal points.

This section is drafted. big Chengde Vanadium Industry Co., Ltd., Guangzhou Nonferrous Metal Research Institute, Northwest Nonferrous Metal Research Institute, Shangluo days Wild Advanced Materials Co., Ltd., Beijing Nonferrous Metal Research Institute, Western Metal Materials Co., Ltd., the high-tech metal material Donggang East Limited.

1 Scope

YS/T 1075 This section provides the vanadium aluminum, master alloy of molybdenum determination of carbon content.

This section applies to aluminum vanadium, molybdenum determination of carbon content of aluminum master alloy. Measurement range. 0.005% to 0.60%.

2 Method summary

High frequency induction heating furnace combustion, burning through the sample into the crucible by electromagnetic induction heating, the sample under high temperature conditions in carbon and a small amount of CO2 released in the form of CO, CO2 and CO into the infrared detection cell for testing.

3 Reagents and materials

3.1 Carrier gas. oxygen (volume fraction of not less than 99.99%).

3.2 Power gas. nitrogen (0.28MPa) or oil-free compressed air.

3.3 iron flux. wC<=0.0005%.

3.4 tungsten tin flux. wC<=0.0008%.

3.5 porcelain crucible. 900 °C ~ 1100 °C after burning to 4h constant blank value removed in a desiccator.

3.6 standard sample.

4 Instrument

Carbon and sulfur analyzer (including the high-frequency furnace, vacuum devices, carrier gas purification system, analysis of the gas conversion system, infrared detection system).

5 Sample

The specimen shall crush a particle size less than 500µm. If oil test results will be high, we need to use an organic reagent (carbon tetrachloride, ether, Acetone, etc.) to clean and pulverized detected.

6 Step, Analysis

6.1 Warm up

To fully preheated before instrumental analysis, so that the indicators of the instrument reaches the set value.

6.2 Instrument Leak

The use of the instrument or other auxiliary equipment leak detection program to determine the instrument without leakage phenomenon.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 4 pages — is available in the English PDF.

How to Download YS/T 1075.6-2015

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
4 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

YS/T 1075.6-2015

$90.00