Scope

YS/T 1075.1-2015 is the English-translated version of 钒铝、钼铝中间合金化学分析方法 第1部分:铁量的测定 1,10-二氮杂菲分光光度法.

YS/T 1075.1-2015 — YS/T 1075 This section provides the aluminum vanadium, molybdenum determination of aluminum alloy with iron content. This section applies to aluminum vanadium, molybdenum, aluminum master alloys Determination of iron content. Measurement range. 0.010% to 0.50%.

Found what you need?

Document preview — YS/T 1075.1-2015

National Standard of the People's Republic of China

ICS
77.120.99
Classification
H 14

Issued by: Ministry of Industry and Information Technology

Contents

  • Foreword
  • 1 Scope
  • 2 Method summary
  • 3 Reagents
  • 4 Instrument
  • 5 Sample

Foreword

YS/T 1075 "aluminum vanadium, molybdenum intermediate aluminum alloy chemical analysis method" including a total of 8 sections.

--- Part 1. Determination of iron content - 1,10-phenanthroline spectrophotometry;

--- Part 2. Determination of molybdenum content of lead molybdate gravimetric method;

--- Part 3. Determination of silicon content - Molybdenum blue spectrophotometric method;

--- Part 4. vanadium content - Inductively coupled plasma atomic emission spectrometry and ferrous ammonium sulfate titration;

--- Part 5. Determination of aluminum content EDTA titration;

--- Part 6. Determination of carbon content in the high-frequency combustion - infrared absorption method;

--- Part 7. Determination of the amount of oxygen in the inert gas fusion - infrared method;

--- Part 8. molybdenum, aluminum X- determining the amount of fluorescence spectroscopy.

This section YS/T 1075 Part 1.

This section drafted in accordance with GB/T 1.1-2009 given rules.

The non-ferrous metal part by the National Standardization Technical Committee (SAC/TC243) and focal points.

This section is drafted. Northwest Nonferrous Metal Research Institute, Chengde Vanadium big industry limited liability company, Western Metal Materials Co., Ltd., Baoji Titanium Group Ltd., Shangluo Amano Advanced Materials Co., Ltd., Beijing Nonferrous Metal Research Institute, Donggang East high-tech metal material Limited, Ltd. Dalian Rong Gaudet kinds of materials.

1 Scope

YS/T 1075 This section provides the aluminum vanadium, molybdenum determination of aluminum alloy with iron content.

This section applies to aluminum vanadium, molybdenum, aluminum master alloys Determination of iron content. Measurement range. 0.010% to 0.50%.

2 Method summary

Samples with sulfuric acid, nitric acid dissolved. Weakly acidic medium at pH 4 to 6, the iron (II) with 1,10-phenanthroline to generate an orange-red complex it was, in the spectrophotometer at a wavelength of 510nm absorbance is measured.

3 Reagents

3.1 sulfate (11).

3.2 nitric acid (11).

3.3 hydrochloride (11).

3.4 hydroxylamine hydrochloride solution (100g/L).

3.5 acetic acid - ammonium acetate buffer solution. Weigh 500g ammonium acetate dissolved in water, was added 20mL of glacial acetic acid, diluted with water to 1000mL, Mix well.

3.6 1,10-phenanthroline solution (2g/L). Weigh 2g1,10- phenanthroline reagent dissolved in 100mL anhydrous ethanol and transferred to 1000mL Volumetric flask and diluted with water to volume, and mix.

3.7 iron standard stock solution. Weigh 0.1000g metallic iron (wFe>=99.99%) in 200mL beaker, add 30mL hydrochloric acid (3.3), to complete the decomposition temperature heating, was added 5mL of nitric acid (3.2) ferric oxide, nitrogen purge and heating continued oxides. Remove the cooling, the solution was Transferred into 1000mL volumetric flask, dilute with water to volume, and mix. This solution 1mL containing 100µg iron.

3.8 iron standard solution. Pipette 10.00mL iron standard stock solution (3.7) in 100mL volumetric flask, dilute with water to volume, and mix.

This solution 1mL containing 10µg iron.

4 Instrument

Spectrophotometer.

5 Sample

The specimen shall crush a particle size less than 500µm.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 4 pages — is available in the English PDF.

How to Download YS/T 1075.1-2015

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
4 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

YS/T 1075.1-2015

$90.00