Valid

YS/T 1047.1-2015Methods for chemical analysis of copper magnetite. Part 1: Determination of copper content. 2, 2-biquinoly spectrophotometric method and flame atomic absorption spectrometric method (English PDF)

铜磁铁矿化学分析方法 第1部分:铜量的测定2,2′-联喹啉分光光度法和火焰原子吸收光谱法

Preview PDF

This is a limited preview

Buy now to download the full PDF (7 pages)

Need quotation for your management?

Get a formal quotation for YS/T 1047.1-2015 in 30 minutes.

Issued by

Ministry of Industry and Information Technology

Level / Type

National · Recommended

Issue date

April 30, 2015

Implementation date

October 1, 2015

Scope

YS/T 1047.1-2015 is the English-translated version of 铜磁铁矿化学分析方法 第1部分:铜量的测定2,2′-联喹啉分光光度法和火焰原子吸收光谱法.

YS/T 1047.1-2015 — YS/T 1047 This section provides the determination of copper content of copper magnetite. This section applies to the determination of copper content of copper magnetite.

2,2'-quinoline spectrophotometric measurement range (mass fraction) 0.10% 2.50%; flame atomic absorption spectrometry range (mass fraction) of 0.10% to 2.50%.

Found what you need?

Document preview — YS/T 1047.1-2015

National Standard of the People's Republic of China

ICS
73.060.10
Classification
D 31

Issued by: Ministry of Industry and Information Technology

Contents

  • Foreword
  • 1 Scope
  • 2 Normative references
  • 3.1 Method summary
  • 3.2 Reagents

Foreword

YS/T 1047-2015 "Methods for chemical analysis of copper magnetite" is divided into 11 sections.

--- Part 1. Determination of copper content of 2,2'-quinoline spectrophotometry and flame atomic absorption spectrometry;

--- Part 2. Determination of total iron content of dichromate method;

--- Part 3. Copper and iron - Determination of the amount of sodium thiosulfate titration;

--- Part 4. Determination of the amount of sulfur by high frequency combustion infrared absorption spectroscopy;

--- Part 5. Determination of phosphorus content titration;

--- Part 6. copper, total iron, silica, alumina, calcium oxide, magnesium oxide, titanium oxide, manganese and phosphorus contents - wave Long-dispersive X-ray fluorescence spectrometry;

--- Part 7. copper, manganese, aluminum, calcium, magnesium, titanium and phosphorus content - Inductively coupled plasma atomic emission spectrometry;

--- Part 8. silicon dioxide content - Gravimetric method;

--- Part 9. Determination of metallic iron content of sulfonic acid spectrophotometry;

--- Part 10. Determination of the amount of ferrous oxide dichromate method;

--- Part 11. Determination of the amount of magnetic iron dichromate method.

This is Part 1.

This section drafted in accordance with GB/T 1.1-2009 given rules.

The non-ferrous metal part by the National Standardization Technical Committee (SAC/TC243) centralized.

This section is responsible for drafting unit. People's Republic of China Bayuquan Exit Inspection and Quarantine.

Part 1 Drafting Unit. Beijing General Research Institute of Mining and Metallurgy.

This section Method 2 drafting units. Northwest Nonferrous Metal Research Institute.

Part 1 participated in the drafting unit. People's Republic of China Bayuquan Entry-Chinalco Luoyang Copper Co., Dongying Fangyuan Nonferrous Metals Co., Ltd., Beijing Nonferrous Metal Research Institute.

This section participated in the drafting Method 2. People's Republic of China Lianyungang Exit Inspection and Quarantine, Beijing General Research Institute of Mining and Metallurgy, aluminum Luoyang Copper Co., People's Republic of China Bayuquan Exit Inspection and Quarantine, Dongying Fangyuan Nonferrous Metals Co., Daye Nonferrous Design and Research Co., Ltd., Yanggu Yoshimitsu Copper Co., Ltd., Zhongtiaoshan Nonferrous Metals Group Co., Ltd.

The drafters of section 1. Li Min, FAN Li new, Quine Lijun, Ning Chu, Liu Xia, Wu ink fountain, Zhangdian Kai, Li Weigang, Linyou Bin, Li sweet.

This part of the drafters Method 2. Sunbao Lian, Zhou Kai, Li Bo, Qin Lijun, Dong Qi, Jiang Yu, FAN Li new, Quine Lijun, Wang Hui, Wang Xiuying, Wang Caiyun, Chen Ruomei, Wu ink fountain, Linyou Bin, Feng Yuan, Hujun Kai, million pairs, and Mr. Lee, Ma Lijun, Wang Xiaoxia.

Methods for chemical analysis of copper magnetite Part 1. Determination of copper content 2,2'-quinoline and flame atomic spectrophotometry Absorption Spectrometry

1 Scope

YS/T 1047 This section provides the determination of copper content of copper magnetite.

This section applies to the determination of copper content of copper magnetite. 2,2'-quinoline spectrophotometric measurement range (mass fraction) 0.10% 2.50%; flame atomic absorption spectrometry range (mass fraction) of 0.10% to 2.50%.

2 Normative references

The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. For undated references, the latest edition (including any amendments) applies to this document.

Laboratory use specifications and test methods GB/T 6682 Analysis GB/T 10322.1 iron ore sampling and sample preparation methods 3 1 2,2-linked quinoline spectrophotometry

3.1 Method summary

Samples with hydrochloric acid, nitric acid, perchloric acid, hydrofluoric acid decomposition, under appropriate acidity, ascorbic acid with copper (II), in N, N- dimethyl Formamide in the presence of copper (I) with 2,2'-biquinoline complex forming purple copper (I) complexes, to 548 nm at a measuring wavelength spectrophotometer the amount of absorbance is calculated using the standard curve method of copper content.

3.2 Reagents

Unless otherwise stated, use only in the analysis confirmed analytically pure reagents and third grade water GB/T 6682 regulations.

3.2.1 Ferric oxide (wFe2O3>=99.9%, wCu

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 7 pages — is available in the English PDF.

Referenced standards

How to Download YS/T 1047.1-2015

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
7 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

YS/T 1047.1-2015

$150.00