Valid

YC/T 247-2008Tobacco and tobacco products. Determination of nicotine purity. Gravimetric method using tungstosilicic acid (English PDF)

Preview PDF

This is a limited preview

Buy now to download the full PDF (5 pages)

Need quotation for your management?

Get a formal quotation for YC/T 247-2008 in 30 minutes.

Issued by

State Tobacco Monopoly Administration

Level / Type

National · Recommended

Issue date

April 14, 2008

Implementation date

April 14, 2008

Scope

YC/T 247-2008 (Tobacco and tobacco products. Determination of nicotine purity. Gravimetric method using tungstosilicic acid) is available as an English-translated PDF.

YC/T 247-2008 — This standard specifies the method for determination of silicon by weight nicotinic acid purity. This standard applies to tobacco and tobacco products and nicotine content in flue gas measurement when used nicotine or nicotine calibration analysis method used Determination of the purity of salt.

Principle 2 Nicotine or nicotinic acid salt to react with silicon to form insoluble nicotine silicon tungstate. With sintered glass filter crucible was dried by heating or mining After calcination ashless filter paper manner, the mass of the precipitate, calculated purity nicotine or nicotine salt.

Found what you need?

Document preview — YC/T 247-2008

National Standard of the People's Republic of China

ICS
65.160
Classification
X 87

Issued by: State Tobacco Monopoly Administration

Contents

  • Foreword
  • 1 Scope
  • 3 Reagents and materials
  • 4 Instrument
  • 4.7 Means a filter paper

Foreword

This standard is identical with ISO 13276:1997 "Tobacco and tobacco products - Determination of nicotine purity silicon acid gravimetric method" (in English).

For ease of use, for ISO 13276:1997 This standard made the following editorial changes.

--- Delete ISO 13276:1997 Foreword;

--- Delete ISO 13276:1997 references;

--- Increase in Appendix A "repeatability and reproducibility of test data." Appendix A of this standard is an informative annex.

This standard was proposed by the State Tobacco Monopoly Bureau.

This standard by the National Standardization Technical Committee on Tobacco (TC144) centralized.

This standard drafting units. China Tobacco Standardization Research Center.

1 Scope

This standard specifies the method for determination of silicon by weight nicotinic acid purity.

This standard applies to tobacco and tobacco products and nicotine content in flue gas measurement when used nicotine or nicotine calibration analysis method used Determination of the purity of salt.

Principle 2

Nicotine or nicotinic acid salt to react with silicon to form insoluble nicotine silicon tungstate. With sintered glass filter crucible was dried by heating or mining After calcination ashless filter paper manner, the mass of the precipitate, calculated purity nicotine or nicotine salt.

3 Reagents and materials

Use analytical grade reagents and water should be distilled water or water of equivalent purity.

3.1 silicotungstic acid solution, 12gSiO212WO3 · 26H2O dissolved in 100mL of water.

Note. Avoid using other silicon acid molecular structure, such as 4H2O · SiO210WO3 · 3H2O and 4H2O · SiO212WO3 · 20H2O, because these Crystalline silicon can not generate acid precipitation and nicotine response.

3.2 hydrochloric acid solution A, 20% (volume fraction), diluted with distilled water 20mL hydrochloric acid (rho20 = 1.18g/mL) to 100mL.

3.3 hydrochloric acid solution B, 0.1% (volume fraction) and distilled water 5mL dilute hydrochloric acid solution A (3.2) to 1000mL.

3.4 nicotine solution, rho20 (C10H14N2) = 0.1mg/mL, 2.5mg nicotine is dissolved in distilled water 25mL volumetric flask (4.1), and and to volume.

4 Instrument

Common laboratory apparatus and the following items.

4.1 flask.

4.2 beaker, 250mL.

4.3 surface plate.

4.4 glass rod.

4.5 dryer, containing an effective desiccant.

4.6 sintered glass crucible filtration device.

4.6.1 sintered glass crucible, a pore size of 40µm ~ 100µm.

4.6.2 Buchner filtration bottles.

4.6.3 Vacuum Pump.

4.6.4 oven, the temperature can be controlled at (120 ± 5) °C.

4.7 Means a filter paper

4.7.1 ash-free filter paper.

4.7.2 crucible, porcelain or platinum.

4.7.3 Bunsen burner, the temperature control should be higher than 600 °C.

4.7.4 muffle furnace, the temperature control should be higher than 600 °C.

4.8 Analytical balance, accurate to 0.1mg.

YC/T 247-2008/ISO 13276:1997

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 5 pages — is available in the English PDF.

How to Download YC/T 247-2008

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
5 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

YC/T 247-2008

$75.00