Valid

WS/T 597-2018Virtual print information interaction specification of medical digital imaging (English PDF)

Preview PDF

This is a limited preview

Buy now to download the full PDF (1 pages)

Need quotation for your management?

Get a formal quotation for WS/T 597-2018 in 30 minutes.

Issued by

National Health Commission

Level / Type

National · Recommended

Issue date

April 17, 2018

Implementation date

October 1, 2018

Scope

WS/T 597-2018 (Virtual print information interaction specification of medical digital imaging) is available as an English-translated PDF.

WS/T 597-2018 — This standard specifies the technical content of the medical digital image virtual printing information interaction process. This standard applies to all types of medical and health institutions, medical equipment manufacturers, medical image storage and archiving systems (PACS) at all levels of the country.

Manufacturers and manufacturers of radiology information systems (RIS) are also suitable for software development and evaluation of medical digital image virtual printing.

Found what you need?

Document preview — WS/T 597-2018

National Standard of the People's Republic of China

ICS
11.000
Classification
C 07

Issued by: National Health Commission

Contents

  • Foreword
  • 1 Scope
  • 2 Normative references
  • 3 Terms and definitions
  • 4 Abbreviations
  • 5 Virtual print interaction specification
  • 5.1 Logical properties of virtual print information interaction
  • 5.2 Virtual Print Information Interaction Process
  • 5.3 Virtual Print Interaction Matching Process
  • 5.4 Virtual printing information matching method

Foreword

This standard was drafted in accordance with the rules given in GB/T 1.1-2009.

This standard was proposed by the National Health Standards Committee Information Standards Committee.

This standard was drafted. First Affiliated Hospital of China Medical University, University of Electronic Science and Technology, National Health and Family Planning Commission Statistical Information Center, country University General Hospital, Tongji Medical College of Huazhong University of Science and Technology, West China Hospital of Sichuan University.

1 Scope

This standard specifies the technical content of the medical digital image virtual printing information interaction process.

This standard applies to all types of medical and health institutions, medical equipment manufacturers, medical image storage and archiving systems (PACS) at all levels of the country.

Manufacturers and manufacturers of radiology information systems (RIS) are also suitable for software development and evaluation of medical digital image virtual printing.

2 Normative references

The following documents are indispensable for the application of this standard. For dated references, only the dated version applies to this standard.

quasi. For undated references, the latest edition (including all amendments) applies to this standard.

DICOM Standard.2011 (Digital Imaging and Communications in Medicine.2011)

3 Terms and definitions

The following terms and definitions apply to this document.

Virtual print virtual print Use software to simulate physical printers, generate electronic print files from print client data, and implement and physical print processes simultaneously A printing method that keeps the communication consistent.

4 Abbreviations

The following abbreviations apply to this document.

DICOM Digital Imaging and Communications in Medicine DIMSE DICOM Information Service Element ID identification number (Identity) LO long string (Long String) LUT lookup table (Look-up Table) M/M Mandatory/Mandatory PACS Medical Image Storage and Archive System (Picture Archiving and Communication System) RIS Radiology Information System SCP Service Provider (Serivce Class Provider) SCU Service Class User SH short string (Short String) SOP Service Object Pair UI Unique Identifier UID Unique Identifier U/M Optional/Mandatory U/U Optional/Optional VM Numerical Diversity (Value Multiplicity) VR numerical representation (Value Respresentation)

5 Virtual print interaction specification

5.1 Logical properties of virtual print information interaction

The virtual print information interaction attribute table is shown in Table 1.

Table 1 Virtual Print Information Interaction Attribute Table

Attribute Name Tag (Tag) VR VM Type Check the instance UID (Study Instance UID) (0020,000D) UI 1 1

5.2 Virtual Print Information Interaction Process

The process of virtual printing SCP and SCU information exchange is a specific complete film printing process (see DICOM Standard.2011 Edition Chapter 2) Page 93), as shown in Figure 1, after the completion of the printing session, the service will receive the data content and the inspection information corresponding to the current printing.

Association matching (see Appendix A for a detailed example).

print

SCU

print

SCP

DICOM Film Session N-CREATE DICOM Presentation LUT N-CREATE DICOM Film Box N-CREATE DICOM Image Box N-SET DICOM Film Box N-ACTION DICOM Film Session N-ACTION DICOM Film Box N-DELETE DICOM Film Session N-DELETE Printer status DICOM N-EVENT-REPORT

Figure 1 film printing flow chart

5.3 Virtual Print Interaction Matching Process

5.3.1 Process Matching Information

The SOP classes for the N-CREATE process in the film print session and the N-SET process for the DICOM image box are shown in Table 2.

Table 2 Basic Film Session Attribute Table

SOP class SOP class UID Basic Film Session SOP Class 1.2.840.10008.5.1.1.1 Basic grayscale image box SOP class 1.2.840.10008.5.1.1.4 in the N-CREATE communication process of the film session, the N-CREATE information that the service will receive is shown in Table 3.

Table 3 Basic Film Session Attribute Table

Property Name Tag (Tag) SCU/SCP Check the instance UID (Study Instance UID) (0020, 0010) U/U Related Reference Check (0008,1110) U/U >Related SOP Class UID (0008, 1150) M/M >Related SOP Instance UID (Referenced SOP Instance UID) (0008, 1155) M/M Specified Character Set (0008,0005) U/U Number of Copies (2000,0010) U/M Print Priority (2000,0020) U/M Film Type (2000,0030) U/M Film Destination (2000,0040) U/M Film Session Label (2000,0050) U/U Memory Allocation (2000,0060) U/U Owner ID (2100, 0160) U/U

Note 1. The M/M in the table indicates that the SCU supports the DIMSE service but does not require it to be used on an association. The SCP supports the DIMSE service.

Note 2. U/U in the table indicates that the SCU can support and use the DIMSE service, and the SCP can support the DIMSE service if the SCP does not support the SCU.

The DIMSE service used, which returns a failure status.

Note 3. U/M in the table indicates that the SCU can support and use the DIMSE service, and the SCP supports the DIMSE service.

In the N-SET communication flow of the image box, the N-SET information that the service will receive is shown in Table 4.

Table 4 Basic Gray Image Box N-SET Property Sheet

Property Name Tag (Tag) SCU/SCP Check the instance UID (Study Instance UID) (0020,000D) U/U Related Reading Sequence (0008, 1110) U/U >Related SOP Class UID (0008, 1150) M/M >Related SOP Instance UID (Referenced SOP Instance UID) (0008, 1155) M/M Image Box Position (2020,0010) M/M Basic Grayscale Image Sequence (2020, 0110) M/M >Samples Per Pixel (0028,0002) M/M >Photometric Interpretation (0028,0004) M/M >Rows (0028,0010) M/M >Columns (0028,0011) M/M >Pixel Aspect Ratio (0028,0034) MC/M Required when the ratio is not 1/1 >Bits Allocated (0028,0100) M/M >Memory Bit (Bits Stored) (0028,0101) M/M >High Bit (0028,0102) M/M >Pixel Representation (0028,0103) M/M >Pixel Data (7FE0,0010) M/M Polarity (2020,0020) U/M Magnification Type (2010,0060) U/U

Table 4 (continued)

Smoothing Type (2010,0080) U/U Min Density (2010, 0120) U/U Maximum Density (2010,0130) U/U Configuration Information (2010, 0150) U/U Requested Image Size (2020,0030) U/U Requested Decimate/Crop Behavior (2020,0040) U/U Related Expression LUT Sequence (Referenced Presentation LUT Sequence) (2050,0500) U/U >Related SOP Class UID (0008,1150) U/U >Related SOP Instance UID (0008, 1155) U/U

Note 1. The M/M in the table indicates that the SCU supports the DIMSE service but does not require it to be used on an association. The SCP supports the DIMSE service.

Note 2. U/U in the table indicates that the SCU can support and use the DIMSE service, and the SCP can support the DIMSE service; if the SCP does not support the SCU the DIMSE service used, which returns a failure status.

Note 3. U/M in the table indicates that the SCU can support and use the DIMSE service, and the SCP supports the DIMSE service.

5.4 Virtual printing information matching method

5.4.1 Matching Method 1

The service detected an inspection instance in the N-CREATE process in the film printing session or the N-SET process in the DICOM image box.

UID (Study Instance UID) field for film matching (see Appendix B for an example of an application scenario).

1) Check the instance UID (Study Instance UID) as matching information;

2) Correlate the matching information with the patient information in the business system (such as the PACS system), and finally print the film with the patient.

Files are associated and stored.

5.4.2 Matching method 2

The service does not detect the check instance UID in the N-CREATE process in the film print session and the N-SET process in the DICOM image box.

(Study Instance UID) field for film matching (see Appendix B for an example of an application scenario).

1) Parsing the received film DICOM file, extracting its image data, and extracting the image on the film image by image pattern recognition method Patient ID number (PatientID) and check flow number (AccessionNumber);

2) The identified patient ID number (PatientID), the inspection serial number (AccessionNumber), and the current time as matching information;

3) Associate the matching information with the patient information in the business system (such as PACS system) and confirm the consistency, and finally hit the patient's film Printed files are associated and stored.

The process requires that the technician must check the serial number (PatientID) and the accession number (AccessionNumber) when making a film print layout.

Displayed on the film layout.

Appendix A

(informative appendix) Medical digital image virtual printing interaction specification process example in order to more specifically describe the information specified in this specification during the virtual printing SCU and SCP interaction process, an example illustrates.

The information of a patient's StudyInstanceUID is 1.2.826.0.1.3680043.2.461.555, and the basic communication process is shown in Figure A.1.

-1 Print SCU sends DCIOM Film Session N-CREATE to print SCP-2 Print SCU sends DICOM Presentation LUT N-CREATE to the print SCP-3 Print SCU sends DICOM Film Box N-CREATE to print SCP-4 Print SCU sends DICOM Image Box N-SET to print SCP-5 Print SCU sends DICOM Film Box N-ACTION to print SCP-6 Print SCU sends DICOM Film Session N-ACTION to the print SCP-7 Print SCU sends DICOM Film Box N-DELETE to print SCP-8 Print SCU sends DICOM Film Session N-DELETE to the print SCP-9 Print SCU to get the DICOM N-EVENT-REPROT sent by the print SCP-10 printing SCU release connection

Figure A.1 Medical digital image virtual printing interaction flow chart

The detailed description of each interaction link in Figure A.1 according to this specification is as follows.

-1 means that the print SCU sends a DCIOM Film Session N-CREATE to the print SCP, and the patient field information needs to be.

0020,000D (StudyInstanceUID) UI. 1.2.826.0.1.3680043.2.461.555;

-2 indicates that the print SCU sends a DICOM Presentation LUT N-CREATE to the print SCP;

-3 means that the print SCU sends DICOM Film Box N-CREATE to the print SCP, and the patient field information needs to be.

0020,000D (StudyInstanceUID) UI. 1.2.826.0.1.3680043.2.461.555;

-4 means that the print SCU sends the DICOM Image Box N-SET to the print SCP, and the patient field information needs to be.

0020,000D (StudyInstanceUID) UI. 1.2.826.0.1.3680043.2.461.555;

print

SCU

print

SCP

The sample pseudo code is as follows.

A-ASSOCIATE

N-GET (PRINTER SOP Instance) N-CREATE (Film Session SOP Instance)// must contain 0020,000D. 1.2.826.0.1.3680043.2.461.555 for (each film of film session) N-CREATE (Film Box SOP Instance)// need to include 0020,000D. 1.2.826.0.1.3680043.2.461.555 for (each image of film) N-SET (Image Box SOP Instance that encapsulates a PREFORMATTED IMAGE SOP Instance) //Need to include 0020,000D. 1.2.826.0.1.3680043.2.461.555 If (no collation) N-ACTION (PRINT, Film Box SOP Instance) N-DELETE (Film Box SOP Instance) If (collation) N-ACTION (PRINT, Film Session SOP Instance) N-DELETE (Film Session SOP Instance) N-EVENT-REPORT (PRINTER SOP Instance) A- RELEASE Appendix B (informative appendix) Medical digital image interaction specification application scenario example 1. The DICOM client (such as a radiology device) sends the image data to be printed to the virtual print, and the virtual print receives the data and stores the data.

At the same time, through the virtual printing information matching method 1, the index information is established for the received data, and when the patient needs to take the film, the query can be to print out the current patient film immediately.

2. The DICOM client (such as a radiology device) sends the image data to be printed to the virtual print, and the virtual print receives the data and stores the data.

At the same time, through the virtual printing information matching method 2, the index information is established for the received data, and when the patient needs to take the film, the query can be to print out the current patient film.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 1 pages — is available in the English PDF.

How to Download WS/T 597-2018

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
1 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

WS/T 597-2018

$259.00