WS/T 494-2017Guideline for performance characteristics of immunological qualitative test (English PDF)
This is a limited preview
Buy now to download the full PDF (18 pages)
Need quotation for your management?
Get a formal quotation for WS/T 494-2017 in 30 minutes.
Issued by
National Health and Family Planning Commission of the People's Republic of China
Level / Type
National · Recommended
Issue date
September 6, 2017
Implementation date
March 1, 2018
Scope
WS/T 494-2017 (Guideline for performance characteristics of immunological qualitative test) is available as an English-translated PDF.
WS/T 494-2017 — This standard stipulates the clinical qualitative immunoassay method and clinical qualitative immunological test important routine quality control indicators.
This standard applies to medical laboratories carrying out various clinical qualitative immunoassays.
Found what you need?
Document preview — WS/T 494-2017
National Standard of the People's Republic of China
- ICS
- 11.020
- Classification
- C 50
Issued by: National Health and Family Planning Commission of the People's Republic of China
Contents
- Preface
- Introduction
- 1 Scope
- 2 Terms and Definitions
- 3 Clinical Qualitative Immunoassay Method
- 3.1 Screening Test
- 3.2 Diagnostic Test
- 3.3 Confirmation Test
- 4 Clinical Qualitative Immunoassays Important Regular Items Analysis Quality Control Index
- 4.1 Content
- 4.2 Qualitative Determination of Precision
- 4.3 Qualitative immunoassay precision with results expressed as COI or S/CO ratio
- 4.4 Accuracy
- 4.5 Analytical sensitivity (ie, minimum detection limit)
- 4.6 Detection of Transformed Serum Plates
- 4.7 Analysis Specificity (Cross-Response)
- 4.8 Interference Factors
- Reference
Foreword
This standard was drafted in accordance with the rules given in GB/T 1.1-2009.
Introduction
There are many important routine test items for clinical qualitative immunoassays, with clear clinical significance and wide application. Clinical qualitative immunoassay results Comparable accuracy is the basic need for medical and health work. Enhancing and ensuring the accuracy and comparability of test results is the quality of clinical testing and management.
Improve the important content of the work. Quality management must have clear quality control indicators, clinical qualitative immunoassay important routine test items Analytical quality control indicators mainly include. precision, accuracy, analytical sensitivity (ie, the minimum detection limit), and the ability to detect transformed serum disks Force, analysis of specificity (cross-reactivity) and interference factors.
Existing clinical qualitative immunoassay tests for important routine items have a large gap in detection performance, and even some commercial kits are the quality control indicators, etc. are not given in the book. In addition, the most important performance indicators for these reagents should currently be achieved in some projects.
Low requirements lack corresponding standards and regulations. Therefore, it is difficult for clinical laboratories to fully evaluate the performance of the reagents used and also make the test results the accuracy and comparability are hard to improve.
This standard will be used to determine the detection systems or reagents (including commercial and clinical) required for laboratories carrying out clinical qualitative immunoassays.
Laboratory-made reagents) interpret the interpretation and minimum requirements of analytical quality control indicators to ensure that clinical laboratories can evaluate correctly Related qualitative immunological reagents.
Clinical qualitative immunoassay analysis of important routine items Quality requirements
1 Scope
This standard stipulates the clinical qualitative immunoassay method and clinical qualitative immunological test important routine quality control indicators.
This standard applies to medical laboratories carrying out various clinical qualitative immunoassays.
2 Terms and definitions
The following terms and definitions apply to this document.
Accuracy
The closeness of the analyte to the actual result. The definition of accuracy in qualitative determination means that the sample is positive or negative Determine the degree of agreement between the results and their true results. This is usually achieved through methodological comparisons.
Analytical sensitivity Lower limit detectionlimits the lowest concentration level of the test substance can be repeatedly detected. The lower limit of determination may vary for different types of specimens.
Analytical specificity A test method only reacts to the test substance in the sample and does not react with other substances.
Analyte
The substances or ingredients tested in laboratory tests.
NOTE. Includes any element, ion, mixture, substance, factor, infectious substance, cell, organelle, (enzyme, hormone, or immunogen) activity, identity, presence, or absence, Concentration, activity, intensity, or other features that need to be determined.
Bias bias
The difference between the test result and the true value.
5% detection concentration 5% ofdetectionconcentrat C5 A 5% positive result will result when the analyte is tested at a concentration of C5. When using a sample with a concentration less than C5 for repeatability testing, Continue to get a negative result.
Critical concentration criticalconcentrat C50 Analyte concentrations at or near the critical value will yield 50% positive results when multiple samples are repeatedly tested at this concentration.
50% of negative results.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 18 pages — is available in the English PDF.
How to Download WS/T 494-2017
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
WS/T 404.9-2026 — Reference intervals for common clinical biochemistry tests - Part 9: Serum C-reactive protein, prealbumin, transferrin, beta-2 microglobulin
WS/T 477-2026 — Standard for quantitative D-dimer assay
WS/T 497-2026 — Standard for laboratory diagnosis of invasive fungal disease
Secure payment via Stripe
Payments accepted
WS/T 494-2017
$295.00