SN/T 5259-2020Determination of UV-320, UV-327, UV-328 and UV-350 ultraviolet absorbers in coatings gas chromatography-mass spectrometry (English PDF)
涂料中UV-320、UV-327、UV-328和UV-350紫外线吸收剂的测定 气相色谱-质谱法
This is a limited preview
Buy now to download the full PDF (7 pages)
Need quotation for your management?
Get a formal quotation for SN/T 5259-2020 in 30 minutes.
Issued by
General Administration of Customs
Level / Type
National · Recommended
Issue date
August 27, 2020
Implementation date
March 1, 2021
Scope
SN/T 5259-2020 is the English-translated version of 涂料中UV-320、UV-327、UV-328和UV-350紫外线吸收剂的测定 气相色谱-质谱法.
SN/T 5259-2020 — This standard specifies the content of UV-320, UV-327, UV-328 and UV-350 ultraviolet absorbers in water-based paints and solvent-based paints the gas chromatography-mass spectrometry detection method.
This standard applies to the content of UV-320, UV-327, UV-328 and UV-350 ultraviolet absorbers in water-based paints and solvent-based paints the determination.
Found what you need?
Document preview — SN/T 5259-2020
National Standard of the People's Republic of China
- ICS
- 87-010
- Classification
- G 51
Issued by: General Administration of Customs
Contents
- Foreword
- 1 Scope
- 2 Method summary
- 3 Reagents and materials
- 4 Instruments and equipment
- 5 Sample preparation
- 6 Handling of samples
- 6.1 Extraction
- 6.2 Purification
- 6.3 Preparation of blank test solution
- 7 Determination
- 7.1 Gas chromatography-mass spectrometry conditions
- 7.2 Drawing a standard working curve
- 7.3 Qualitative and quantitative analysis by gas chromatography-mass spectrometry
- 7.4 Blank test
- 8 Calculation results
- 9 Lower limit of determination
- 10 Precision
Foreword
This standard was drafted in accordance with the rules given in GB/T 1.1-2020.
This standard was proposed and managed by the General Administration of Customs of the People's Republic of China.
Drafting organization of this standard. Guangzhou Customs of the People's Republic of China.
1 Scope
This standard specifies the content of UV-320, UV-327, UV-328 and UV-350 ultraviolet absorbers in water-based paints and solvent-based paints the gas chromatography-mass spectrometry detection method.
This standard applies to the content of UV-320, UV-327, UV-328 and UV-350 ultraviolet absorbers in water-based paints and solvent-based paints the determination.
2 Method summary
The sample is leveled on a clean glass sheet, and after natural air drying, the solvent-based paint is ultrasonically extracted with n-hexane, and the water-based paint is ultrasonically extracted with acetonitrile.
Sound extraction. After the extract is concentrated, it is purified by a solid phase extraction column, filtered by a filter membrane, and measured with a gas chromatography-mass spectrometer. External standard Method quantitative.
3 Reagents and materials
Unless otherwise stated, all reagents are chromatographically pure.
3.1 Methanol.
3.2 n-hexane.
3.3 Acetonitrile.
3.8 Single standard stock solution of ultraviolet absorber. accurately weigh the appropriate amount of UV-320 standard material (3.4), UV-327 standard material (3.5), UV-328 standard material (3.6) and UV-350 standard material (3.7), respectively use methanol (3.1) to make a constant volume, and prepare a concentration of 1 000 mg/L Single-label stock solution.
3.9 UV absorber mixed standard stock solution. accurately pipette 1 mL of the above 4 single standard stock solutions (3.8) to 10 mL volume in the bottle (4.7), use methanol (3.1) to make a constant volume and prepare a UV absorber mixed standard stock solution with a concentration of 100 mg/L.
3.10 Mixed standard working solution. accurately pipette 0.05 mL, 0.1 mL, 0.2 mL, 0.5 mL, 1 mL, 2 mL, 5 mL of the above mixture the standard stock solution (3.9) is placed in 7 10 mL volumetric flasks (4.7), and the volume is fixed with methanol (3.1), and the concentration is 0.5 mg/L, 1 Mixed standard working solutions of mg/L, 2 mg/L, 5 mg/L, 10 mg/L, 20 mg/L, 50 mg/L.
3.11 Silica gel cartridge (6 mL, 1 g). activate with 6 mL methanol (3.1) before use and keep it wet.
3.12 Microporous membrane. 0.2 µm pore size, organic type.
4 Instruments and equipment
4.1 Gas Chromatography Mass Spectrometer. Equipped with EI source.
4.2 Analytical balance. Sensitivity 0.1 mg.
4.3 Ultrasonic generator.
4.4 Rotary evaporator.
4.5 Pipette. 0 mL ~ 10 mL.
4.6 Conical flask with stopper. 50 mL.
4.7 Volumetric flask. 10 mL.
4.8 Round bottom flask. 50 mL.
4.9 Glass sheet. 10 cm×20 cm.
5 Sample preparation
Stir the sample evenly and level it on a clean glass sheet (4.9) to form a thin film of appropriate thickness. Dry naturally in a ventilated place, and wait After it is completely dry, scrape it off with a razor blade, cut into pieces and mix well.
6 Handling of samples
6.1 Extraction
Accurately weigh 0.5 g of the air-dried sample (accurate to 0.1 mg), place it in a 50 mL conical flask (4.6) with a stopper, and add 20 mL of Extraction agent, ultrasonic extraction for 20 min. Carefully transfer the supernatant into a 50 mL round-bottomed flask (4.8), rinse with 10 mL extractant 3 times Put a stoppered Erlenmeyer flask (4.6), and put the eluent into a 50 mL round bottom flask (4.8). Concentrate to nearly 1 mL with a rotary evaporator (4.4), to be purified.
Note. The extractant of solvent-based paint film is n-hexane (3.2), and the extractant of water-based paint film is acetonitrile (3.3).
6.2 Purification
Transfer the sample solution treated in 6.1 to the activated silica gel cartridge (3.11), and control the flow rate to 1 drop every 2 seconds. Use 6 mL Elute with methanol (3.1), collect the eluate, and dilute to 10 mL with methanol (3.1). After being filtered by a microporous membrane (3.12), it is used for gas color Spectrum-mass spectrometry.
6.3 Preparation of blank test solution
Except that no sample is added, all follow the above steps.
7 Determination
7.1 Gas chromatography-mass spectrometry conditions
Since the test results depend on the instrument used, it is impossible to give general parameters for gas chromatography/mass spectrometry. Set parameters it should be ensured that the measured component and other components can be effectively separated during chromatographic determination. The following parameters are proved to be feasible.
a) Chromatographic column. DB-5 MS, 30 m × 0.25 mm (inner diameter) × 0.25 mm (film thickness), or equivalent performance.
b) Column temperature. 100 °C (1 min) 20 °C/min.200 °C (1 min) 5 °C/min 290 °C (5 min).
c) Temperature of the injection port. 280 °C.
d) Chromatography-mass spectrometry interface temperature. 300 °C.
e) Ion source temperature. 230 °C.
f) Quadrupole temperature. 150 °C.
g) Carrier gas. helium, purity >= 99.999%, 1.0 mL/min.
h) Ionization method. EI.
i) Ionization energy. 70 eV.
j) Mass scanning range. 50 amu ~ 450 amu.
k) Measurement method. SCAN mode.
l) Injection volume. 1.0 µL, without splitting.
m) Solvent delay. 4 min.
7.2 Drawing a standard working curve
According to the measurement conditions listed in 7.1, test the mixed standard working solution (3.10). Take the measured substance concentration as the abscissa, with the peak area corresponding to the quantitative ion is the ordinate, and the standard working curve is drawn to obtain the linear equation. Typical gas phase of 4 kinds of UV absorbers refer to Appendix A for the total ion current diagram of Chromatography-Mass Spectrometer A.1.
7.3 Qualitative and quantitative analysis by gas chromatography-mass spectrometry
Analyze the liquid to be tested according to the above analysis conditions (7.1), according to the retention time of the chromatographic peak and the ultraviolet the qualitative ion of the absorbent is qualitatively analyzed. Perform quantitative analysis according to the standard working curve (7.2).
7.4 Blank test
Carry out a blank test with the sample, and carry out pre-processing and testing according to the sample processing steps.
8 Calculation results
The content of various ultraviolet absorbers in the sample is calculated according to formula (1).
9 Lower limit of determination
The lower limit of the four ultraviolet absorbers in this method is 10 mg/kg.
10 Precision
The repeatability and reproducibility of the method are shown in Table 1 and Table 2.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 7 pages — is available in the English PDF.
How to Download SN/T 5259-2020
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
SN/T 0330-2025 — General rules for microbiological examinations of export food
SN/T 0987.1-2025 — Rules for inspection of IBCs for export dangerous goods - Part 1: General specifications
SN/T 0987.2-2025 — Rules for inspection of IBCs for export dangerous goods - Part 2: General specifications
Secure payment via Stripe
Payments accepted
SN/T 5259-2020
$150.00