Valid

SN/T 5252-2020Determination of Cu, Cr, Mn, Ba, Co, TI.Nb, Ta, Ti, Mo, Y, La, Ce, Pr, Nd, Sm, EU, Gd, Dy, Ho, Er, Tm, Yb in imported iron ore-Inductively coupled plasma mass spectrometry(ICP-MS) (English PDF)

进口铁矿石中铜、铬、锰、钡、钴、铊、铌、钽、钛、钼、钇、镧、铈、镨、钕、钐、铕、钆、镝、钬、铒、铥、镱含量的测定 电感耦合等离子体质谱法

Preview PDF

This is a limited preview

Buy now to download the full PDF (7 pages)

Need quotation for your management?

Get a formal quotation for SN/T 5252-2020 in 30 minutes.

Issued by

General Administration of Customs

Level / Type

National · Recommended

Issue date

August 27, 2020

Implementation date

March 1, 2021

Scope

SN/T 5252-2020 is the English-translated version of 进口铁矿石中铜、铬、锰、钡、钴、铊、铌、钽、钛、钼、钇、镧、铈、镨、钕、钐、铕、钆、镝、钬、铒、铥、镱含量的测定 电感耦合等离子体质谱法.

SN/T 5252-2020 — This standard specifies the microwave digestion-inductively coupled plasma mass spectrometry method for the determination of various imported iron such as hematite, magnetite, and limonite.

Copper, chromium, manganese, barium, cobalt, thallium, niobium, tantalum, titanium, molybdenum, yttrium, lanthanum, cerium, praseodymium, neodymium, samarium, europium, gadolinium, dysprosium, holmium, Methods for the content of 23 elements such as erbium, thulium, and ytterbium.

This standard is applicable to copper, chromium, manganese, barium, cobalt, thallium, niobium,, copper, chromium, manganese, barium, cobalt, hematite, magnetite, limonite and other imported iron ore.

Determination of 23 elements including tantalum, titanium, molybdenum, yttrium, lanthanum, cerium, praseodymium, neodymium, samarium, europium, gadolinium, dysprosium, holmium, erbium, thulium, and ytterbium. Its determination the range is shown in Table 1.

Found what you need?

Document preview — SN/T 5252-2020

National Standard of the People's Republic of China

ICS
73.060.10
Classification
D 31

Issued by: General Administration of Customs

Contents

  • Foreword
  • 1 Scope
  • 2 Normative references
  • 3 Principles of the method
  • 4 Reagents and materials
  • 5 Apparatus and equipment
  • 6 Sample preparation
  • 7 Analysis steps
  • 7.1 Sample
  • 7.2 Number of determinations
  • 7.3 Blank test
  • 7.4 Digestion of the sample
  • 7.5 Quantitative determination
  • 8 Result calculation
  • 9 Precision

Foreword

This standard was drafted in accordance with the rules given in GB/T 1.1-2009.

This standard was proposed and managed by the General Administration of Customs of the People's Republic of China.

Drafting organizations of this standard. Qingdao Customs of the People's Republic of China, Shijiazhuang Customs of the People's Republic of China.

1 Scope

This standard specifies the microwave digestion-inductively coupled plasma mass spectrometry method for the determination of various imported iron such as hematite, magnetite, and limonite.

Copper, chromium, manganese, barium, cobalt, thallium, niobium, tantalum, titanium, molybdenum, yttrium, lanthanum, cerium, praseodymium, neodymium, samarium, europium, gadolinium, dysprosium, holmium, Methods for the content of 23 elements such as erbium, thulium, and ytterbium.

This standard is applicable to copper, chromium, manganese, barium, cobalt, thallium, niobium,, copper, chromium, manganese, barium, cobalt, hematite, magnetite, limonite and other imported iron ore.

Determination of 23 elements including tantalum, titanium, molybdenum, yttrium, lanthanum, cerium, praseodymium, neodymium, samarium, europium, gadolinium, dysprosium, holmium, erbium, thulium, and ytterbium. Its determination the range is shown in Table 1.

2 Normative references

The following documents are indispensable for the application of this document. For dated reference documents, only the dated version applies to this article Pieces. For undated reference documents, the latest version (including all amendments) is applicable to this document.

GB/T 602 Preparation of standard solutions for impurity determination of chemical reagents GB/T 6682 Analytical laboratory water specifications and test methods GB/T 8170 Numerical rounding rules and the expression and determination of limit values GB/T 10322.1 Iron ore sampling and sample preparation method

3 Principles of the method

After the sample is digested by microwave, it is introduced into an inductively coupled plasma mass spectrometer for measurement. Using online internal standard, the mass spectrum signal of the element to be measured is compared with the intensity ratio of the internal standard element mass spectrum signal is proportional to the concentration of the element to be measured for quantitative analysis.

4 Reagents and materials

Unless otherwise specified, only use the reagents above the superior grade and the water is the second grade water that meets the requirements of GB/T 6682.

4.1 Hydrochloric acid (rho 1.19 g/mL).

4.2 Hydrofluoric acid (rho 1.30 g/mL).

4.3 Nitric acid (rho 1.42 g/mL).

4.4 Nitric acid solution (2 98, volume ratio). Take an appropriate amount of nitric acid (4.3) and ultrapure water and mix with a volume ratio of 2.98.

4.5 Copper, chromium, manganese, barium, cobalt, thallium, niobium, tantalum, titanium, molybdenum, yttrium, lanthanum, cerium, praseodymium, neodymium, samarium, europium, gadolinium, dysprosium, holmium, erbium, Thulium and Ytterbium standard stock solutions (1 000 µg/mL). Prepare according to GB/T 602 or directly purchase certified reference materials.

4.6 Standard solution series. Use standard stock solution (4.5) to prepare mixed standard working solution series according to Table 2.

4.7 Mass spectrometry tuning solution. 1 µg/L mixed standard solution of lithium, yttrium, cerium, thallium, and cobalt, prepared according to GB/T 602 or directly purchased with a certified standard substance.

4.8 Mixed internal standard solution. 10 mg/L mixed standard solution of scandium, lutetium, indium, bismuth, germanium, rhodium, and terbium, prepared according to GB/T 602 or directly Purchase certified reference materials.

4.9 Internal standard solution (online internal standard solution). take 2.5 mL of mixed internal standard solution (4.8) and dilute to the volume with 2% nitric acid (volume fraction) 50 mL to obtain a standard internal standard solution with a concentration of 500 µg/L.

4.10 Argon gas. purity >= 99.99%.

4.11 Helium. purity >= 99.99%.

5 Apparatus and equipment

5.1 Inductively Coupled Plasma Mass Spectrometer (ICP-MS). equipped with hydrofluoric acid solution atomization injection system. See Appendix A for instrument operating parameters.

5.2 High temperature pressure microwave digestion apparatus. see Appendix B for working parameters.

5.3 Analytical balance. Sensitivity 0.1 mg.

5.4 Pipette. The pipette has a volume of 100 µL, 1,000 µL, and 10 mL.

6 Sample preparation

Prepare the analysis sample according to the provisions of GB/T 10322.1, bake it at 105°C for 2 h, then place it in a desiccator and cool to room temperature spare.

7 Analysis steps

7.1 Sample

Weigh 0.10 g sample to the nearest 0.0001 g.

7.2 Number of determinations

Weigh two samples for parallel measurement, and take the average of the results.

7.3 Blank test

Except that the sample to be tested is not added, the blank test shall be carried out in accordance with 7.4.

7.4 Digestion of the sample

Add 7 mL of hydrochloric acid (4.1), 1 mL of hydrofluoric acid (4.2), and 2.5 mL of nitric acid (4.3) to the sample, shake well, tighten the sealed digestion tank, Put it into the microwave digestion apparatus. Refer to the working conditions of microwave digestion in Appendix B for microwave digestion. Take it out, cool to room temperature, turn on the Dissolve the tank, transfer the digested solution directly to a 100 mL plastic volumetric flask, rinse the digestion tank and lid with deionized water 3~5 times, wash liquid Combine it into the mother liquor, dilute to the mark with 2% nitric acid, mix well, and let stand for measurement.

7.5 Quantitative determination

7.5.1 Drawing the standard curve

Use the tuning solution (4.7) to tune the various indicators of the instrument to meet the measurement requirements, establish the analysis program according to the instrument manual, and edit the measurement Method (see Table A.1 for the working parameters of the inductively coupled plasma mass spectrometer), select the elements to be measured and the corresponding internal standard elements (see Table A.1) A.2), the standard series of solutions are measured in the order of concentration from low to high, the signal intensity of each measured element and its internal standard element signal intensity value the ratio is the response value of the element, and the standard curve is drawn with the response value as the ordinate and the concentration as the abscissa.

7.5.2 Determination of sample solution

Measure the blank solution and the sample solution in sequence. The concentration obtained from the calibration curve is the concentration of each element in the test solution.

concentration.

8 Result calculation

The content of the measured element is calculated according to formula (1).

9 Precision

The precision was measured by 8 laboratories on 4 levels of samples, and the data was determined after statistics. The results are shown in Table 3.

Note. X is the average of test results, mg/kg.

Continued

Appendix A

(Informative appendix) Inductively coupled plasma mass spectrometer working parameters and measured elements and internal standard elements to determine the mass number Appendix B (Informative appendix) Working Parameters of Microwave Digestion Apparatus

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 7 pages — is available in the English PDF.

Referenced standards

How to Download SN/T 5252-2020

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
7 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

SN/T 5252-2020

$135.00