Valid

SN/T 3321.2-2013Limestone and dolomite. Part 2: Determination of carbon and sulfur content. High frequency combustion with infrared absorption method (English PDF)

Preview PDF

This is a limited preview

Buy now to download the full PDF (13 pages)

Need quotation for your management?

Get a formal quotation for SN/T 3321.2-2013 in 30 minutes.

Issued by

General Administration of Quality Supervision, Inspection and Quarantine of PRC

Level / Type

National · Recommended

Issue date

February 9, 2015

Implementation date

September 1, 2015

Scope

SN/T 3321.2-2013 (Limestone and dolomite. Part 2: Determination of carbon and sulfur content. High frequency combustion with infrared absorption method) is available as an English-translated PDF.

SN/T 3321.2-2013 — This standard specifies the method for the measurement of volatile organic compounds (VOCs) in packing materials through the static headspace gas chromatography.

This standard is applicable to the measurement of volatile organic compounds of the known chemical compositions in in packing materials; however, the volatile organic compounds as generated due to the thermal degradation of packing materials are not covered by the measurement scope of this standard.

Found what you need?

Document preview — SN/T 3321.2-2013

National Standard of the People's Republic of China

Issued by: General Administration of Quality Supervision, Inspection and Quarantine of PRC

Contents

  • Foreword...3
  • 1 Scope...4
  • 2 Normative references...4
  • 3 Terms and definitions...4
  • 4 Principle...5
  • 5 Reagents and materials...5
  • 6 Devices...7
  • 7 Sample preparation and storage...9
  • 8 Analysis steps...10
  • 9 Precision...13

Foreword

This standard was drafted in accordance with the rules given in GB/T 1.1-2009.

This standard was proposed by AND shall be under the jurisdiction of the

National Certification and Accreditation Administration.

The drafting organizations of this standard. Shanghai Entry-exit Inspection and

Quarantine Bureau of the People's Republic of China.

1 Scope

This standard specifies the method for the measurement of volatile organic

compounds (VOCs) in packing materials through the static headspace gas

chromatography.

This standard is applicable to the measurement of volatile organic compounds

of the known chemical compositions in in packing materials; however, the

volatile organic compounds as generated due to the thermal degradation of

packing materials are not covered by the measurement scope of this standard.

2 Normative references

The following documents are essential to the application of this document. For

the dated documents, only the versions with the dates indicated are applicable

to this document; for the undated documents, only the latest version (including

all the amendments) are applicable to this standard.

GB/T 6682 Water for analytical laboratory use – Specification and tests

methods

3 Terms and definitions

The following terms and definitions apply to this document.

3.1

Packaging materials

It is the general term of the materials that are used to manufacture the

packaging containers AND constitute the packaging of the packed product.

3.2

Polymer packaging

immediately with water, OR otherwise seek treatment immediately if

serious. The volatile substances such as vinyl chloride and acrylonitrile

shall not be released into the laboratory air. It shall prepare and treat the

standard sample in a well-ventilated fume hood.

The reagents and water used in this standard are, unless otherwise noted or

required, analytical pure reagents and class III water as specified in GB/T 6682.

5.1 Methanol

5.2 Solvents. it is used to dissolve the polymer, AND it shall not contain any

interference which has the same retention time as that of the volatile component

to be measured. Typical polymer solvents include.

a) Dimethylformamide (DMF);

b) Dimethylacetamide (DMAC);

c) Propylene carbonate;

d) O-dichlorobenzene.

Note. The volatile contaminants in the solvent can be removed through an inert

gas purging for 24 h ~ 48 h.

5.3 Diluent. it is used to dilute and prepare the standard working solution of

volatile organic compounds, its retention time in the gas chromatography shall

be inconsistent with that of the substance to be measured, AND the commonly

used diluent includes.

a) Water;

b) n-Hexadecane.

5.4 Volatile organic standard sample. the highest concentrations available for

commercial analysis of volatile organic compounds by this method. Examples

of volatile organic compounds that may be present in the styrene polymer

package are as follows.

a) Styrene;

b) Acrylonitrile.

c) Butadiene;

d) Benzene;

Note. Suitable detectors include the following detectors.

a) Flame ionization detector (FID), which is used for the detection of

conventional organic volatiles;

b) Mass spectrometer (MSD), which is used for the detection of conventional

organic volatiles;

c) Electron capture detector (ECD), which is used for the detection of halides;

d) Nitrogen and phosphorus detector (NPD), which is used for the detection

of acrylonitrile.

6.2 Gas chromatographic column. Select a capillary gas chromatographic

column which can separate the components to be measured. As for the volatile

organic analysis of the styrene polymer package (1, 3-butadiene, acrylonitrile,

styrene, benzene, toluene, ethylbenzene, cumene), it is preferable to select HP-

INNOWA x 60 m x 0.32 mm (inner diameter) x 0.25 µm OR its equivalent.

6.3 Automatic headspace sampler. it is composed of the thermostatic sample

tray and the related accessories as required to reach to the requirements for

headspace vapour automatic sample injection.

6.4 Headspace bottle. 20 mL ~ 25 mL, with a rubber stopper gasket.

6.5 Syringe. it is calibrated; and the gas-tight syringes for headspace gas

chromatographic sample injection can be heated during sampling and injection

process.

6.6 Low-temperature freezing mill. with sieves of different apertures.

6.7 Constant temperature oven. it can maintain the temperature of 80 °C ~

150 °C (± 2 °C).

6.8 Analytical balance. its sensitivity is 0.0001 g.

Note 1. AVOID contacting with heated portion of the chromatograph, such

as detectors, columns, sample trays, hot vials, etc.

Note 2. Once heated, pressure is created in the sample vial containing the

polymer volatile components. After analysis, it shall use the syringe to empty

the pressure in the vial.

8.1.3 Headspace analysis conditions

The headspace heating temperature and time conditions are selected in

accordance with 8.1.2. Other headspace conditions are dependent on the

instrument used. OPTIMIZE the relevant parameters to obtain stable analysis

results and large detection signal values. The typical headspace analysis

conditions are shown in Appendix A.

8.2 Calibration

8.2.1 Calibration with solvent dissolution

Accurately PIPETTE the standard working solution A of certain volume [5.6.b)]

into the headspace bottle; the pipetted solution volume shall be consistent with

the volume of the solvent which is used to dissolve the sample in 7.4; quickly

SEAL the headspace bottle; PREPARE for the headspace-gas

chromatographic analysis. The calibration curve shall contain at least 5 different

concentrations.

8.2.2 Calibration without solvent dissolution

USE the calibrated syringe (6.5) to pipette a certain volume (2.0 µL ~ 10.0 µL)

of standard working solution B [5.6.c)] to the bottom of the headspace bottle;

quickly SEAL the headspace bottle; PREPARE for the headspace-gas

chromatographic analysis. The calibration curve shall contain at least 5 different

concentrations.

8.2.3 If the substrate of the sample to be measured has a great influence on

the measurement results of some volatile organic compounds, USE the

aforementioned two methods for measurement; if the recovery rate of the

sample to be measured cannot reach to the analysis requirements, it is allowed

to use the standard addition method in the Appendix B for detection.

Note. The calibration method described above requires periodic and repeated

calibration of the standard sample, AND the repeated calibration period is

determined based on the stability status of the chromatograph.

8.3 Headspace sample injection

8.3.1 Automatic sample analysis

PLACE the calibrated sample as mentioned in 8.2 AND the tested samples as

prepared in 7.4 and 7.5 into the constant temperature sample tray of the

automatic headspace sample injector (6.3); SET the headspace analysis

conditions in accordance with 8.1.3; then RUN it.

APPENDIX A

(Informative)

Typical headspace-gas chromatographic conditions

A.1 Examples of typical gas chromatographic conditions

USE the measurement chromatographic conditions of the volatile organic

compounds in styrene polymer packages as an example, since the

measurement results are depending onto the instruments used, so it is not

possible to provide the universal parameters for gas chromatography. The set

parameters shall ensure that, during the chromatographic measurement, the

measured components and other components can be effectively separated; the

following parameters are proved to be feasible.

a) Chromatography column. HP-INNOWAX capillary column 60 m x 0.32 mm

(inner diameter) x 0.25 µm, or the...

......

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 13 pages — is available in the English PDF.

Referenced standards

How to Download SN/T 3321.2-2013

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
13 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

SN/T 3321.2-2013

$120.00