SN/T 3321.2-2013Limestone and dolomite. Part 2: Determination of carbon and sulfur content. High frequency combustion with infrared absorption method (English PDF)
This is a limited preview
Buy now to download the full PDF (13 pages)
Need quotation for your management?
Get a formal quotation for SN/T 3321.2-2013 in 30 minutes.
Issued by
General Administration of Quality Supervision, Inspection and Quarantine of PRC
Level / Type
National · Recommended
Issue date
February 9, 2015
Implementation date
September 1, 2015
Scope
SN/T 3321.2-2013 (Limestone and dolomite. Part 2: Determination of carbon and sulfur content. High frequency combustion with infrared absorption method) is available as an English-translated PDF.
SN/T 3321.2-2013 — This standard specifies the method for the measurement of volatile organic compounds (VOCs) in packing materials through the static headspace gas chromatography.
This standard is applicable to the measurement of volatile organic compounds of the known chemical compositions in in packing materials; however, the volatile organic compounds as generated due to the thermal degradation of packing materials are not covered by the measurement scope of this standard.
Found what you need?
Document preview — SN/T 3321.2-2013
National Standard of the People's Republic of China
Issued by: General Administration of Quality Supervision, Inspection and Quarantine of PRC
Contents
- Foreword...3
- 1 Scope...4
- 2 Normative references...4
- 3 Terms and definitions...4
- 4 Principle...5
- 5 Reagents and materials...5
- 6 Devices...7
- 7 Sample preparation and storage...9
- 8 Analysis steps...10
- 9 Precision...13
Foreword
This standard was drafted in accordance with the rules given in GB/T 1.1-2009.
This standard was proposed by AND shall be under the jurisdiction of the
National Certification and Accreditation Administration.
The drafting organizations of this standard. Shanghai Entry-exit Inspection and
Quarantine Bureau of the People's Republic of China.
1 Scope
This standard specifies the method for the measurement of volatile organic
compounds (VOCs) in packing materials through the static headspace gas
chromatography.
This standard is applicable to the measurement of volatile organic compounds
of the known chemical compositions in in packing materials; however, the
volatile organic compounds as generated due to the thermal degradation of
packing materials are not covered by the measurement scope of this standard.
2 Normative references
The following documents are essential to the application of this document. For
the dated documents, only the versions with the dates indicated are applicable
to this document; for the undated documents, only the latest version (including
all the amendments) are applicable to this standard.
GB/T 6682 Water for analytical laboratory use – Specification and tests
methods
3 Terms and definitions
The following terms and definitions apply to this document.
3.1
Packaging materials
It is the general term of the materials that are used to manufacture the
packaging containers AND constitute the packaging of the packed product.
3.2
Polymer packaging
immediately with water, OR otherwise seek treatment immediately if
serious. The volatile substances such as vinyl chloride and acrylonitrile
shall not be released into the laboratory air. It shall prepare and treat the
standard sample in a well-ventilated fume hood.
The reagents and water used in this standard are, unless otherwise noted or
required, analytical pure reagents and class III water as specified in GB/T 6682.
5.1 Methanol
5.2 Solvents. it is used to dissolve the polymer, AND it shall not contain any
interference which has the same retention time as that of the volatile component
to be measured. Typical polymer solvents include.
a) Dimethylformamide (DMF);
b) Dimethylacetamide (DMAC);
c) Propylene carbonate;
d) O-dichlorobenzene.
Note. The volatile contaminants in the solvent can be removed through an inert
gas purging for 24 h ~ 48 h.
5.3 Diluent. it is used to dilute and prepare the standard working solution of
volatile organic compounds, its retention time in the gas chromatography shall
be inconsistent with that of the substance to be measured, AND the commonly
used diluent includes.
a) Water;
b) n-Hexadecane.
5.4 Volatile organic standard sample. the highest concentrations available for
commercial analysis of volatile organic compounds by this method. Examples
of volatile organic compounds that may be present in the styrene polymer
package are as follows.
a) Styrene;
b) Acrylonitrile.
c) Butadiene;
d) Benzene;
Note. Suitable detectors include the following detectors.
a) Flame ionization detector (FID), which is used for the detection of
conventional organic volatiles;
b) Mass spectrometer (MSD), which is used for the detection of conventional
organic volatiles;
c) Electron capture detector (ECD), which is used for the detection of halides;
d) Nitrogen and phosphorus detector (NPD), which is used for the detection
of acrylonitrile.
6.2 Gas chromatographic column. Select a capillary gas chromatographic
column which can separate the components to be measured. As for the volatile
organic analysis of the styrene polymer package (1, 3-butadiene, acrylonitrile,
styrene, benzene, toluene, ethylbenzene, cumene), it is preferable to select HP-
INNOWA x 60 m x 0.32 mm (inner diameter) x 0.25 µm OR its equivalent.
6.3 Automatic headspace sampler. it is composed of the thermostatic sample
tray and the related accessories as required to reach to the requirements for
headspace vapour automatic sample injection.
6.4 Headspace bottle. 20 mL ~ 25 mL, with a rubber stopper gasket.
6.5 Syringe. it is calibrated; and the gas-tight syringes for headspace gas
chromatographic sample injection can be heated during sampling and injection
process.
6.6 Low-temperature freezing mill. with sieves of different apertures.
6.7 Constant temperature oven. it can maintain the temperature of 80 °C ~
150 °C (± 2 °C).
6.8 Analytical balance. its sensitivity is 0.0001 g.
Note 1. AVOID contacting with heated portion of the chromatograph, such
as detectors, columns, sample trays, hot vials, etc.
Note 2. Once heated, pressure is created in the sample vial containing the
polymer volatile components. After analysis, it shall use the syringe to empty
the pressure in the vial.
8.1.3 Headspace analysis conditions
The headspace heating temperature and time conditions are selected in
accordance with 8.1.2. Other headspace conditions are dependent on the
instrument used. OPTIMIZE the relevant parameters to obtain stable analysis
results and large detection signal values. The typical headspace analysis
conditions are shown in Appendix A.
8.2 Calibration
8.2.1 Calibration with solvent dissolution
Accurately PIPETTE the standard working solution A of certain volume [5.6.b)]
into the headspace bottle; the pipetted solution volume shall be consistent with
the volume of the solvent which is used to dissolve the sample in 7.4; quickly
SEAL the headspace bottle; PREPARE for the headspace-gas
chromatographic analysis. The calibration curve shall contain at least 5 different
concentrations.
8.2.2 Calibration without solvent dissolution
USE the calibrated syringe (6.5) to pipette a certain volume (2.0 µL ~ 10.0 µL)
of standard working solution B [5.6.c)] to the bottom of the headspace bottle;
quickly SEAL the headspace bottle; PREPARE for the headspace-gas
chromatographic analysis. The calibration curve shall contain at least 5 different
concentrations.
8.2.3 If the substrate of the sample to be measured has a great influence on
the measurement results of some volatile organic compounds, USE the
aforementioned two methods for measurement; if the recovery rate of the
sample to be measured cannot reach to the analysis requirements, it is allowed
to use the standard addition method in the Appendix B for detection.
Note. The calibration method described above requires periodic and repeated
calibration of the standard sample, AND the repeated calibration period is
determined based on the stability status of the chromatograph.
8.3 Headspace sample injection
8.3.1 Automatic sample analysis
PLACE the calibrated sample as mentioned in 8.2 AND the tested samples as
prepared in 7.4 and 7.5 into the constant temperature sample tray of the
automatic headspace sample injector (6.3); SET the headspace analysis
conditions in accordance with 8.1.3; then RUN it.
APPENDIX A
(Informative)
Typical headspace-gas chromatographic conditions
A.1 Examples of typical gas chromatographic conditions
USE the measurement chromatographic conditions of the volatile organic
compounds in styrene polymer packages as an example, since the
measurement results are depending onto the instruments used, so it is not
possible to provide the universal parameters for gas chromatography. The set
parameters shall ensure that, during the chromatographic measurement, the
measured components and other components can be effectively separated; the
following parameters are proved to be feasible.
a) Chromatography column. HP-INNOWAX capillary column 60 m x 0.32 mm
(inner diameter) x 0.25 µm, or the...
......
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 13 pages — is available in the English PDF.
Referenced standards
Normative references
How to Download SN/T 3321.2-2013
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 6682-2008 — Water for analytical laboratory use - Specification and test methods
SN/T 3321.1-2012 — Limestone and dolomite - Part 1: Determination of magnesium, silicon, aluminum, iron, manganese and phosphorus content - Inductively coupled plasma atomic emission spectrometry
SN/T 1537-2023 — Rules for the inspection of radioactivity of imported minerals
Secure payment via Stripe
Payments accepted
SN/T 3321.2-2013
$120.00