SN/T 3311-2012Detection method for influenza A 2009(H1N1)virus by real-time PCR at frontier port (English PDF)
国境口岸甲型H1N1(2009)流感病毒的荧光定量PCR检测方法
This is a limited preview
Buy now to download the full PDF (6 pages)
Need quotation for your management?
Get a formal quotation for SN/T 3311-2012 in 30 minutes.
Issued by
General Administration of Customs
Level / Type
National · Recommended
Issue date
December 12, 2012
Implementation date
July 1, 2013
Scope
SN/T 3311-2012 is the English-translated version of 国境口岸甲型H1N1(2009)流感病毒的荧光定量PCR检测方法.
SN/T 3311-2012 - This standard specifies the fever or upper respiratory tract infections and other symptoms of infection suspected person has a frontier port discovered influenza H1N1 (2009) Biosecurity requirements influenza virus detection, sample collection, transport and storage, sample preparation, nucleic acid extraction and rapid detection methods.
This standard applies to border crossings suspected of being infected person carries influenza A H1N1 (2009) influenza virus detection.
Found what you need?
Document preview — SN/T 3311-2012
National Standard of the People's Republic of China
Issued by: General Administration of Customs
Contents
- Foreword
- 1 Scope
- 2 Normative references
- 3 Terms and Definitions
- 4 Detects objects
- 5 Laboratory bio-safety requirements
Foreword
This standard was drafted in accordance with GB/T 1.1-2009 given rules.
This standard is proposed and managed by the National Certification and Accreditation Administration Committee.
This standard was drafted. Chinese Academy of Inspection and Quarantine.
1 Scope
This standard specifies the fever or upper respiratory tract infections and other symptoms of infection suspected person has a frontier port discovered influenza H1N1 (2009) Biosecurity requirements influenza virus detection, sample collection, transport and storage, sample preparation, nucleic acid extraction and rapid detection methods.
This standard applies to border crossings suspected of being infected person carries influenza A H1N1 (2009) influenza virus detection.
2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. For undated references, the latest edition (including any amendments) applies to this document.
GB 19489 General requirements for laboratory biosafety WS233-2002 Microbiological and Biomedical Laboratories Biosafety Common Criteria can infect humans highly pathogenic microorganisms (viruses) or sample transport regulations (People's Republic of China Ministry of Health Order no. 45)
3 Terms and Definitions
The following terms and definitions apply to this document.
Influenza A H1N1 (2009) influenza virus influenzaA2009 (H1N1) virus One kind in April 2009 to give the new virus from Mexico and the United States isolated the patient, the virus belongs to the Orthomyxoviridae (Ortho-myxoviridae) influenza virus type A influenza virus. From genes, the genetic component of the virus from North American swine flu virus, North American avian influenza viruses, human influenza virus subtype H1N1 is common in Asia and Europe, the swine flu virus. For a named argument States Varying the initial outbreak of the virus, commonly known as swine flu, there is another swine flu, human swine (type) influenza, Mexican flu, North American influenza, Novel H1N1 flu, swine flu and 2009 H1N1 flu. April 30, 2009 World Health Organization renamed this virus Influenza A H1N1 influenza virus. This standard the virus called influenza A H1N1 (2009) influenza virus.
4 Detects objects
Staff with fever or symptoms of upper respiratory tract infections suspected of being infected frontier port discovery.
5 Laboratory bio-safety requirements
5.1 CHECK personal protective reference GB 19489.
5.2 The laboratory shall follow GB 19489 and WS233-2002 Biosafety Level 2 (BSL-2) is required for biosafety laboratories.
5.3 Used Lab Supplies shall comply with GB 19489 requirements for the processing of waste treatment and disposal.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 6 pages — is available in the English PDF.
Referenced standards
Normative references
- GB 19489Laboratories - General requirements for biosafety
- WS 233-2002General biosafety standard for causative bacteria laboratories
can infect humans highly pathogenic microorganisms (poisonous) species or specimen transport regulations (Ministry of Health Order No. 45)
How to Download SN/T 3311-2012
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Fast delivery
After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB 19489-2004 — Laboratories - General requirements for biosafety
GB 19489-2008 — Laboratories - General requirements for biosafety
WS 233-2002 — General biosafety standard for causative bacteria laboratories
SN/T 3311-2012
$169.00