SN/T 3077.2-2012Test method of flash point. Modified continuously closed cup tester (English PDF)
闪点的测定改良连续闭杯法
This is a limited preview
Buy now to download the full PDF (7 pages)
Need quotation for your management?
Get a formal quotation for SN/T 3077.2-2012 in 30 minutes.
Issued by
General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China
Level / Type
National · Recommended
Issue date
March 1, 2013
Implementation date
September 16, 2013
Scope
SN/T 3077.2-2012 is the English-translated version of 闪点的测定改良连续闭杯法.
SN/T 3077.2-2012 is the Chinese standard "Test method of flash point. Modified continuously closed cup tester". Its scope clause reads: This Standard specifies the determination method of high performance liquid chromatography of tetrabromobisphenol A bis (2,3-dibromopropyl ether) in electrical and electronic equipment.
This Standard is applicable to the determination of tetrabromobisphenol A bis (2,3-dibromopropyl ether) in plastic parts of electrical and electronic equipment.
Its clauses include method summary; reagents and materials. It was issued by the General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China on 2013-03-01 and took effect on 2013-09-16.
Found what you need?
Document preview — SN/T 3077.2-2012
National Standard of the People's Republic of China
Issued by: General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China
Contents
- Foreword...3
- 1 Scope...4
- 2 Normative references...4
- 3 Method summary...4
- 4 Reagents and materials...4
- 5 Instruments and equipment...5
- 6 Sample preparation...5
- 7 Analysis steps...5
- 8 Result calculation...7
- 9 Report...7
- 10 Method's linear range, low detection limit, and precision...7
1 Scope
This Standard specifies the determination method of high performance liquid chromatography of tetrabromobisphenol A bis (2,3-dibromopropyl ether) in electrical and electronic equipment.
This Standard is applicable to the determination of tetrabromobisphenol A bis (2,3-dibromopropyl ether) in plastic parts of electrical and electronic equipment.
2 Normative references
The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.
GB/T 6682, Water for analytical laboratory use - Specification and test methods
3 Method summary
Use toluene-methanol as extraction solvent to conduct microwave extraction of
Tetrabromobisphenol A bis (2, 3-dibromopropyl ether), referred to as BDDP. The extraction solution is purified. Use high performance liquid chromatography to analyze.
4 Reagents and materials
Unless otherwise stated, all reagents used are analytical reagents. Water used is grade one water that complies with GB/T 6682. All solvents for liquid chromatography mobile phases are chromatographically pure and filtered by a
0.45µm filter membrane.
4.1 Toluene: chromatographically pure.
in an extraction can. Accurately pipette 20mL of toluene + methanol (4.5). Seal and place in the microwave extraction instrument (5.2). Rise the temperature to
115°C within 5min. Maintain for more than 15min. Cool to room temperature. If the extraction solution is cloudy and cannot be filtered through a filter, then accurately pipette 2mL of sample extraction solution. Conduct precipitation purification treatment according to 7.2. If the extraction solution is clear, then directly use a 0.46µm nylon filter membrane. Then take part of the filtrate for chromatographic analysis.
7.2 Precipitation purification
In 2mL of extraction solution that is obtained after processing as 7.1, accurately add 6mL of n-hexane or methanol. If precipitation occurs in the solution, it shall conduct centrifuge separation. After removing the serum, set volume to 10mL.
Use a 0.46µm nylon filter membrane to filter, then conduct spectrum analysis.
7.3 Chromatographic conditions
Since the test results depend on the instrument used, it is not possible to give general parameters for liquid chromatography. The set parameters shall ensure that the measured component can be effectively separated from other components during chromatographic determination. The parameters given below prove to be feasible.
a) Chromatographic column: C18 reverse-phase column [150 × 4.6mm (inner diameter) × 5µm] or equivalent;
b) Column temperature: 30°C;
c) Isocratic elution: acetonitrile (4.3) + water (95 + 5, V/V);
d) Detection wavelength: 230nm;
e) Injection volume: 10µL;
f) Flow rate: 0.8mL/min.
7.4 Determination
Inject the samples of standard solution (4.8) and sample solution with equal volume alternately. Determine the nature according to chromatographic retention time of standard solution. Use external standard method to quantify based on chromatographic peak area.
Analyze the standard solution according to the above analysis conditions (7.3).
See Annex A for its typical chromatogram.
7.5 Blank test
......
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 7 pages — is available in the English PDF.
Referenced standards
Normative references
How to Download SN/T 3077.2-2012
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 6682-2008 — Water for analytical laboratory use - Specification and test methods
SN/T 3077.1-2012 — Test method for flash point by continuously closed cup tester
SN/T 0330-2025 — General rules for microbiological examinations of export food
Secure payment via Stripe
Payments accepted
SN/T 3077.2-2012