Valid

SN/T 2763.4-2012Chemical analysis of nickel laterite ore - Part 4: Determination of nickel, cobalt, aluminum, magnesium and phosphorus content - Inductively coupled plasma atomic emission spectrometric method (English PDF)

红土镍矿化学分析方法 第4部分:镍、钴、铝、镁、磷含量的测定 电感耦合等离子体原子发射光谱法

Preview PDF

This is a limited preview

Buy now to download the full PDF (8 pages)

Need quotation for your management?

Get a formal quotation for SN/T 2763.4-2012 in 30 minutes.

Issued by

General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China

Level / Type

National · Recommended

Issue date

December 12, 2012

Implementation date

July 1, 2013

Scope

SN/T 2763.4-2012 is the English-translated version of 红土镍矿化学分析方法 第4部分:镍、钴、铝、镁、磷含量的测定 电感耦合等离子体原子发射光谱法.

SN/T 2763.4-2012 is the Chinese standard "Chemical analysis of nickel laterite ore - Part 4: Determination of nickel, cobalt, aluminum, magnesium and phosphorus content - Inductively coupled plasma atomic emission spectrometric method".

Its scope clause reads: This Part of SN/T 3323 specifies inductively coupled plasma atomic emission spectrometry (ICP-AES), the testing method to determine the lead, chromium, cadmium contents in mill scale.

This Part is applicable to the determination of lead, chromium, cadmium contents in mill scale. The lower limit of determination for each element is shown in Table 1.

Table 1 -- Lower limit of determination for each element. Its clauses include principle; reagents and materials; instruments; result calculation. It was issued by the General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China on 2012-12-12 and took effect on 2013-07-01.

Found what you need?

Document preview — SN/T 2763.4-2012

National Standard of the People's Republic of China

Issued by: General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China

Contents

  • Foreword...3
  • 1 Scope...4
  • 2 Normative references...4
  • 3 Principle...4
  • 4 Reagents and materials...5
  • 5 Instruments...5
  • 6 Specimen...6
  • 7 Determination steps...6
  • 8 Result calculation...7
  • 9 Precision...8

1 Scope

This Part of SN/T 3323 specifies inductively coupled plasma atomic emission spectrometry (ICP-AES), the testing method to determine the lead, chromium, cadmium contents in mill scale.

This Part is applicable to the determination of lead, chromium, cadmium contents in mill scale. The lower limit of determination for each element is shown in Table 1.

Table 1 -- Lower limit of determination for each element

2 Normative references

The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.

GB/T 6379.2, Measurement methods and results - Accuracy (trueness and precision)

- Part 2: Determine the standard methods of measurement repeatability and reproducibility of the basic method

GB/T 6682, Water for analytical laboratory use - Specification and test methods

GB/T 12806, Laboratory glassware - One-mark volumetric flasks

GB/T 12808, Laboratory glassware - One-mark pipettes

3 Principle

The specimen is decomposed by hydrochloric acid. Use the inductively coupled plasma

Element Mass fraction % atomic emission spectrometer for testing. Use the matrix matching method to eliminate the matrix effects.

4 Reagents and materials

Unless otherwise stated, all reagents are analytically pure and above. Water is grade two water specified in GB/T 6682.

4.1 Hydrochloric acid (rho= 1.19g/mL): Guaranteed reagent.

4.2 High-purity iron powder: The iron mass fraction is greater than 99.98%.

4.3 Hydrochloric acid (1+1): Add 1 volume of hydrochloric acid (4.1) to 1 volume of water. Mix well.

4.4 Lead, chromium, cadmium standard solution (certified reference material):

1000µg/mL.

4.5 35mg/mL iron matrix solution: Weigh 3.5g of high-purity iron powder (4.2). Add

40mL of hydrochloric acid solution (4.3). Heat to dissolve. Use water to set volume constant in a 100mL volumetric flask.

5 Instruments

5.1 Inductively coupled plasma atomic emission spectrometer

5.1.1 Performance indicator

The spectrometer can also be sequential, multi-channel or full-spectral. In either type, it shall meet the following performance indicator:

The correlation coefficient (r) of the standard curve of each element to be tested is greater than 0.995.

5.1.2 Working state of instrument

Start the ICP-AES instrument. According to the operating procedures of the instrument, warm up the instrument and adjust various conditions and measurement parameters of the instrument, so that the performance of the instrument meets the requirements of

5.1.1.

5.1.3 Confirmation of spectral lines for determination

Choose the appropriate spectral lines according to the instrument conditions. The selection of the spectral lines shall follow the following rules:

volumetric flask. Use water to set the volume constant. Shake well. Determine on the inductively coupled plasma atomic emission spectrometer with selected operating parameters.

7.4 Preparation of working curve

Add 10mL of iron matrix solution (4.5), 8mL of HCl (4.1) into a set of 100mL volumetric flasks. Respectively pipette a certain amount of standard solutions of each element into the volumetric flask. Use water to dilute to the scale. Shake well. The content of the test element shall be within the range of the working curve made. The quantity of the series of standard solution shall be decided by the precision requirements.

It requires not to be less than 4. See Annex B for the solution concentration of the recommended calibration curve.

7.5 Measurement

7.5.1 Measurement of calibration curve

Adjust the instrument according to the provisions in 5.1.2. Measure the spectral intensity of each test element in the series solutions of calibration curve (7.4) at the analysis line in turn. The instrument automatically returns to establish a linear equation.

Its correlation coefficient (r) shall comply with 5.1.1 regulations.

7.5.2 Determination of test solution

Introduce the test solution (7.3) into the plasma in turn. Respectively determine the spectrum strength of each test element and internal standard elements at the same analysis line. The instrument shall automatically calculate the corresponding concentration of each element according to the calibration curve.

8 Result calculation

Calculate the content of each element according to formula (1), in mass fraction.

Where,

Xi - The content of each test element i (mass fraction), %;

ci - The mass concentration of test element found from the working curve, in micrometers per milliliter (µg/ mL);

V - The constant volume of test solution, in milliliters (mL);

......

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 8 pages — is available in the English PDF.

Referenced standards

How to Download SN/T 2763.4-2012

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
8 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

SN/T 2763.4-2012

$190.00