Valid

SN/T 1718-2006Examination codes of relapsing fever at entry-exit port (English PDF)

出入境口岸回归热检验规程

Preview PDF

This is a limited preview

Buy now to download the full PDF (8 pages)

Need quotation for your management?

Get a formal quotation for SN/T 1718-2006 in 30 minutes.

Issued by

The General Administration of Quality Supervision, Inspection and Quarantine

Level / Type

National · Recommended

Issue date

January 26, 2006

Implementation date

August 16, 2006

Scope

SN/T 1718-2006 is the English-translated version of 出入境口岸回归热检验规程.

SN/T 1718-2006 — This standard stipulates the object, method, result report and positive result disposal of the returning heat of the entry and exit ports. This standard applies to the return heat test at entry and exit ports.

Found what you need?

Document preview — SN/T 1718-2006

National Standard of the People's Republic of China

ICS
11
Classification
C 62

Issued by: The General Administration of Quality Supervision, Inspection and Quarantine

Contents

  • Foreword
  • 1 Scope
  • 2 Terms and definitions
  • 3 Objects
  • 4 Specimen processing
  • 4.1 Blood specimens
  • 4.2 Urine specimen
  • 4.3 Media specimens
  • 5 Preparation
  • 6 Laboratory test methods
  • 7 Results report
  • 7.1 Microscope inspection report

Foreword

Appendix B of this standard is a normative appendix, Appendix A, Appendix C, and Appendix D are informative appendices.

This standard is proposed and managed by the National Certification and Accreditation Administration.

This standard was drafted. Shenzhen Entry-Exit Inspection and Quarantine Bureau of the People's Republic of China.

1 Scope

This standard stipulates the object, method, result report and positive result disposal of the returning heat of the entry and exit ports.

This standard applies to the return heat test at entry and exit ports.

2 Terms and definitions

The following terms and definitions apply to this standard.

An acute infectious disease caused by arthropods caused by Borrelia.

3 Objects

3.1 Entry and exit personnel suspected of being infected with the regenerative heat spiral.

3.2 Collect cockroaches and cockroaches from animals in endemic areas.

4 Specimen processing

4.1 Blood specimens

Blood samples from patients with fever (body temperature above 39 °C) were collected, placed at room temperature for 1 h, and centrifuged at 3000 r/min.

At 15 min, the serum was aspirated for testing. The serum after centrifugation can be stored in the refrigerator at 2 ° C ~ 8 ° C if it is detected within 3 days;

Stored in a refrigerator at -20 ° C for long-term storage and should be stored in a -80 ° C refrigerator.

4.2 Urine specimen

Fresh urine samples 3mL ~ 5mL immediately sent for inspection.

4.3 Media specimens

More than 10 collected cesium and strontium were washed with 500µ LEDTA-Na2 and dried. Store in liquid nitrogen or store below -80 °C.

5 Preparation

See Appendix A for the preparation of test reagents.

6 Laboratory test methods

The inspection methods for returning to the hot spiral laboratory at the entry and exit ports are as follows.

---Microscope test, see Appendix B;

--- Serological tests, see Appendix C;

--- Polymerase chain reaction (PCR) detection, see Appendix D.

7 Results report

7.1 Microscope inspection report

7.1.1 Directly using dark-field microscopy or microscopy after staining, if you see curly hair, the length is about 2 to 5 times the diameter of red blood cells.

Borrelia can be reported as "detecting the regression thermospirate"; if it is not found, the report "no regression thermobolism detected" is also indicated, and the detection method is also indicated.

7.1.2 Quantitative analysis of whole blood brownish yellow layer (QBC), when the fluorescing spiral is concentrated at the interface, the report "detects the regression hot spiral

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 8 pages — is available in the English PDF.

How to Download SN/T 1718-2006

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
8 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

SN/T 1718-2006

$165.00