Valid

SN/T 1654-2005Determination of 2, 3, 5, 6-tetrachlorophenol residues in leather and leather products for import and export. Acetylation gas chromatography (English PDF)

进出口皮革及皮革制品中2,3,5,6-四氯苯酚残留量的测定 乙酰化气相色谱法

Preview PDF

This is a limited preview

Buy now to download the full PDF (5 pages)

Need quotation for your management?

Get a formal quotation for SN/T 1654-2005 in 30 minutes.

Issued by

General Administration of Quality Supervision, Inspection and Quarantine of the People Republic of China

Level / Type

National · Recommended

Issue date

September 30, 2005

Implementation date

May 1, 2006

Scope

SN/T 1654-2005 is the English-translated version of 进出口皮革及皮革制品中2,3,5,6-四氯苯酚残留量的测定 乙酰化气相色谱法.

SN/T 1654-2005 — This standard specifies the method for determination of 2,3,5,6-tetrachlorophenol and its salts in leather and leather products. This standard applies to the determination of 2,3,5,6-tetrachlorophenol and its salts in various leathers and their products.

Found what you need?

Document preview — SN/T 1654-2005

National Standard of the People's Republic of China

ICS
59.140.01
Classification
Y 45

Issued by: General Administration of Quality Supervision, Inspection and Quarantine of the People Republic of China

Contents

  • Foreword
  • 1 Scope
  • 2 Normative references
  • 3 Method summary
  • 4 Reagents
  • 4.4 Sulfuric acid (rho=1.84g/cm
  • 5 Instruments and equipment

Foreword

Appendix A of this standard is an informative annex.

This standard is proposed and managed by the National Certification and Accreditation Administration.

This standard was drafted. Zhejiang Entry-Exit Inspection and Quarantine Bureau of the People's Republic of China.

1 Scope

This standard specifies the method for determination of 2,3,5,6-tetrachlorophenol and its salts in leather and leather products.

This standard applies to the determination of 2,3,5,6-tetrachlorophenol and its salts in various leathers and their products.

2 Normative references

The terms in the following documents become the terms of this standard by reference to this standard. All dated references, followed by all Modifications (not including errata content) or revisions do not apply to this standard, however, parties to agreements based on this standard are encouraged to study is it possible to use the latest version of these files? For undated references, the latest edition applies to this standard.

GB/T 6682 Analytical laboratory water specifications and test methods QB/T 3812.1 Leather laboratory sample parts and signs QB/T 3812.2 Air conditioning of leather physical property test strips

3 Method summary

The 2,3,5,6-tetrachlorophenol and its salts remaining in the leather are extracted into the aqueous phase by forming a potassium salt in the potassium carbonate solution, and the extract is acidified.

After that, it was back extracted with n-hexane. After purification, it is extracted with a potassium carbonate solution to the aqueous phase. Add acetic anhydride to form 2,3,5,6-tetrachlorophenol ethyl ester, Finally, it is extracted with n-hexane. Determined by gas chromatography electron capture detector and quantified by internal standard method.

4 Reagents

Unless otherwise stated, the distilled or deionized water used in this standard shall meet the requirements of GB/T 6682 Class III water.

4.1 Potassium carbonate. analytically pure.

4.2 Potassium carbonate solution. 0.1 mol/L, 13.8 g of potassium carbonate was dissolved in 1000 mL of distilled water.

4.3 n-hexane. analytically pure.

4.4 Sulfuric acid (rho=1.84g/cm

3). Analytical purity.

4.5 Acetic anhydride. analytically pure.

4.6 2,3,5,6-tetrachlorophenol standard. purity >99%.

4.7 Standard stock solution of 2,3,5,6-tetrachlorophenol. 100 µg/mL, prepared with 0.1 mol/L potassium carbonate solution.

4.8 Aldrin internal standard solution. prepared with n-hexane at a concentration of about 0.05 µg/mL.

5 Instruments and equipment

5.1 Gas Chromatograph. equipped with an electron capture detector.

5.2 Constant temperature oscillating water bath.

5.3 Vortex mixer.

5.4 Centrifuge.

5.5 Erlenmeyer. 100 mL with a ground plug.

5.6 Glass core funnel. No. 2.

5.7 Micro-syringe. 10µL, 100µL each.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 5 pages — is available in the English PDF.

Referenced standards

How to Download SN/T 1654-2005

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
5 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

SN/T 1654-2005

$85.00