Valid

SN/T 1599-2005Determination for major elements in coal ash by ICP-AES (English PDF)

煤灰中主要成分的测定 电感耦合等离子体原子发射光谱法

Preview PDF

This is a limited preview

Buy now to download the full PDF (8 pages)

Need quotation for your management?

Get a formal quotation for SN/T 1599-2005 in 30 minutes.

Issued by

General Administration of Quality Supervision, Inspection and Quarantine of PRC

Level / Type

National · Recommended

Issue date

September 2, 2009

Implementation date

March 16, 2010

Scope

SN/T 1599-2005 is the English-translated version of 煤灰中主要成分的测定 电感耦合等离子体原子发射光谱法.

SN/T 1599-2005 is the Chinese standard "Determination for major elements in coal ash by ICP-AES". Its scope clause reads: This Standard specifies determination of bisphenol A in polycarbonate resin and its products by gas chromatography-mass spectrometry.

This Standard is applicable to the determination of bisphenol A in polycarbonate resin and its products. Its clauses include method summary; reagents and materials; lower limit of detection; precision.

It was issued by the General Administration of Quality Supervision, Inspection and Quarantine of PRC on 2009-09-02 and took effect on 2010-03-16.

Found what you need?

Document preview — SN/T 1599-2005

National Standard of the People's Republic of China

Issued by: General Administration of Quality Supervision, Inspection and Quarantine of PRC

Contents

  • Foreword...3
  • 1 Scope...4
  • 2 Method Summary...4
  • 3 Reagents and Materials...4
  • 4 Apparatus...5
  • 5 Preparation of the Sample...5
  • 6 Analytical Procedures...5
  • 7 Calculation of Results...7
  • 8 Lower Limit of Detection...8
  • 9 Precision...8

1 Scope

This Standard specifies determination of bisphenol A in polycarbonate resin and its products by gas chromatography-mass spectrometry.

This Standard is applicable to the determination of bisphenol A in polycarbonate resin and its products.

2 Method Summary

Acetone was used as the extraction solvent for the specimen. After ultrasonic extraction, derivatization was carried out by pentafluoropropionic anhydride. The solution was blown dry by nitrogen. Use n-hexane to make constant volume; and analyzed by gas chromatography-mass spectrometry.

3 Reagents and Materials

3.1 Acetone: chromatographically pure.

3.2 n-hexane: chromatographically pure.

3.3 Pentafluoropropionic anhydride: purity >=98%.

3.4 Bisphenol A standard product: CAS: 80-05-7, purity >=99%.

3.5 Bisphenol A standard stock solution: accurately weigh 10mg of bisphenol A

standard (3.4); place it in a 100mL volumetric flask; dilute to the mark by acetone (3.1);

and mix well. The concentration of this solution is 100g/L.

3.6 Preparation of standard working solution: respectively pipette appropriate volume

of bisphenol A standard stock solution (3.5); dilute by acetone (3.1) to prepare standard working solution with required concentration.

at 4000 r/min for 15 min in a centrifuge (4.7). Absorb the supernatant by a syringe (4.8);

pass the injecting solution through a 0.20µm organic filter membrane (4.9); and collect the filtrate in a brown bottle. Pipette 1mL of the filtrate to a graduated centrifuge tube accurately; add 100µL of derivatization reagent pentafluoropropionic anhydride (3.3);

place in a vortex mixer (4.10) and vortex to mix; derivatize in a constant temperature water bath (4.11) at 60°C for 30min. After that, place it in a nitrogen blower (4.12) and slowly blow it to near dryness. Add 1mL of n-hexane (3.2); vortex to mix; and transfer the solution to the sample injecting bottle for gas chromatography-mass spectrometry detection.

6.3 Preparation of standard working solution

Accurately transfer a certain volume of standard solution with the appropriate concentration to the graduated centrifuge tube (4.6); add 100µL of the derivatization reagent pentafluoropropionic anhydride (3.3); and follow the 6.2 derivatization procedures below.

6.4 Gas chromatography – mass spectrometry conditions

6.4.1 Chromatographic column: 30m × 0.25mm (inner diameter) × 0.25µm (film

thickness); HP-5MS quartz capillary column or equivalent.

6.4.2 Chromatographic column temperature: initial temperature is 70°C, maintain for

1min; then raise the temperature to 210°C at 30°C/min; and then raise the temperature to 260°C at 10°C/min, and maintain for 2min.

6.4.3 Inlet temperature: 260°C;

6.4.4 Mass spectrometer interface temperature: 280°C;

6.4.5 Carrier gas: helium, purity >=99.99%; flowrate of 1.0mL/min;

6.4.6 Sample injecting method: split-less injection; open the valve after 1.0min;

6.4.7 Sample injecting quantity: 1µL;

6.4.8 Electric ionization method: EI;

6.4.9 Electric ionization energy: 70eV;

6.4.10 Determination method: selective ion monitoring method;

6.4.11 Select monitoring ion (m/z): 265, 505, 520;

6.4.12 Solvent delay time: 5min.

6.5 Gas chromatography – mass spectrometry determination

M – specimen mass, in g.

8 Lower Limit of Detection

This method’s lower limit of the detection is 0.05 mg/kg.

9 Precision

Determine the reliability of the results (95% confidence level) as follows:

9.1 Repeatability

In the same laboratory, the same person uses the same equipment, the same test method, and the absolute difference between the two parallel determination results of the same test object within the day is no greater than 10% of the arithmetic mean of the two measured values.

9.2 Reproducibility

In different laboratories, the same person uses the same equipment and the same test method. The absolute difference between two parallel measurements of the same object is no greater than 15% of the arithmetic mean of the two measured values.

......

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 8 pages — is available in the English PDF.

How to Download SN/T 1599-2005

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
8 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

SN/T 1599-2005

$85.00