SJ/T 11792-2022Test method for conductivity of electrode materials used in lithium ion battery (English PDF)
Also coversSJT11792-2022
This is a limited preview
Buy now to download the full PDF (10 pages)
Need quotation for your management?
Get a formal quotation for SJ/T 11792-2022 in 30 minutes.
Issued by
General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China
Level / Type
National · Recommended
Issue date
April 6, 2007
Implementation date
October 16, 2007
Scope
SJ/T 11792-2022 (Test method for conductivity of electrode materials used in lithium ion battery) is available as an English-translated PDF.
SJ/T 11792-2022 is the Chinese standard "Test method for conductivity of electrode materials used in lithium ion battery".
Its scope clause reads: This Part of SN/T 0481 specifies inductively coupled plasma atomic emission spectrometry (hereinafter referred as ICP-AES), the method to determine ferric oxide (Fe2O3), titanium dioxide (TiO2), silicon dioxide (SiO2), calcium oxide (CaO), magnesium oxide (MgO) content in bauxite.
This Part is applicable to the determination of Fe2O3, TiO2, SiO2, CaO, MgO content in bauxite. See Table 1 for the determination range of each element. Its clauses include method summary; reagents; calculation of analysis result.
It was issued by the General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China on 2007-04-06 and took effect on 2007-10-16.
Found what you need?
Document preview — SJ/T 11792-2022
National Standard of the People's Republic of China
Issued by: General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China
Contents
- Foreword...3
- 1 Scope...4
- 2 Normative references...4
- 3 Method summary...4
- 4 Reagents...5
- 5 Instruments and equipment...6
- 6 Sampling and sample preparation...6
- 7 Specimen preparation...7
- 8 Analysis steps...7
- 9 Calculation of analysis result...8
- 10 Precision...9
- Annex A (informative) Working conditions and detection limit of instrument...10
1 Scope
This Part of SN/T 0481 specifies inductively coupled plasma atomic emission spectrometry (hereinafter referred as ICP-AES), the method to determine ferric oxide (Fe2O3), titanium dioxide (TiO2), silicon dioxide (SiO2), calcium oxide (CaO), magnesium oxide (MgO) content in bauxite.
This Part is applicable to the determination of Fe2O3, TiO2, SiO2, CaO, MgO content in bauxite. See Table 1 for the determination range of each element.
2 Normative references
The provisions in following documents become the provisions of this Part of SN/T 0481 through reference in this Standard. For dated references, the subsequent amendments (excluding corrigendum) or revisions do not apply to this Part, however, parties who reach an agreement based on this Part are encouraged to study if the latest versions of these documents are applicable. For undated references, the latest edition of the referenced document applies.
GB/T 2007 (all parts), General rules for the sampling and sample preparation of minerals in bulk
3 Method summary
The specimen uses lithium tetraborate as the flux. After it is melted at a high temperature, use hydrochloric acid to extract. After the volume is set constant, use ICP-
AES instrument to determine the emission spectrum intensity of the test element in the test solution. Find corresponding concentration from the working curve. Calculate its content.
4 Reagents
Unless otherwise specified, it shall only use the confirmed analytically-pure reagents and distilled water or equivalent-pure water in the analysis.
4.1 Graphite powder: Powder, 100 meshes, carbon content >= 98.5%.
4.2 Argon: >=99.99%.
4.3 Hydrogen peroxide (rho=1.10g/mL).
4.4 Hydrochloric acid (rho=1.19g/mL).
4.5 Hydrochloric acid solution (1+9).
4.6 Hydrochloric acid solution (1+3).
4.7 Lithium tetraborate.
4.8 Lithium tetraborate solution (10g/L): Weigh 1.0g of lithium tetraborate (4.7). Add
50mL of hydrochloric acid solution (4.5). Slightly heat it to make it dissolved. Use water to set the volume constant into a 100mL volumetric flask. Mix well for use.
4.9 Aluminum standard solution (10mg/mL): Accurately weigh 1.0000g of high purity
aluminum (99.99%) into a 200mL beaker. Add 40mL of hydrochloric acid solution (4.6).
Boil it till it is clear. If it is insoluble, it may add a certain amount of hydrogen peroxide (4.3). Cool down. Transfer it into a 100mL volumetric flask. Use water to dilute to the scale. Mix well. 1mL of this solution contains 10mg of aluminum.
4.10 Iron, titanium, calcium, and magnesium standard stock solutions (1mg/mL).
4.11 Silicon standard stock solution (0.5mg/mL).
4.12 Mixed standard solution: Respectively pipette 40.00mL of silicon standard stock
solution (4.9.3); 15.00mL of iron, titanium standard stock solutions (4.9.2) each;
5.00mL of calcium, magnesium standard stock solutions (4.9.2) each -- into 100mL volumetric flasks. Then add 10.00mL of concentrated hydrochloric acid (4.4). Set the volume constant. Mix well for use. See Table 2 of the content of each element.
tweezers to take the molten beads out. Use a brush to remove the graphite powder attached to the surface. Put the molten beads into the beaker. Add 40mL of hydrochloric acid solution (4.6). Place it in the (55 ± 5)°C constant temperature water bath oscillator.
Immerse till the molten beads are completely dissolved. Filter into a 250mL volumetric flask. Set the volume constant. Mix well for ICP-AES determination.
8.4 Spectral measurement
8.4.1 Instrument optimization
Start the ICP-AES instrument. Adjust the working conditions and measurement parameters of the instrument to the best state (see Annex A).
8.4.2 Drawing of working curve
Introduce the standard solution series (8.3.1) into the plasma in sequence. Measure the spectral signal intensity of each analysis line. Use the strength as Y-axis, the concentration (µg/mL) of each test element in each standard solution as X-axis, to obtain the working curve of each element. Perform linear regression. Calculate the correlation coefficient. The correlation coefficient shall meet the requirements of 5.4.4.
8.4.3 Determination of test solution
Introduce the blank solution (8.2) and the test material solution (8.3.2) into the plasma.
Respectively measure the spectral intensity of each test element. According to the working curve, obtain the concentration of each corresponding component. If the number of samples is large, the standard sample can be inserted into the sample measurement gap as a control sample, so as to control the accuracy of the analysis result.
9 Calculation of analysis result
Calculate the content of oxides of each element according to formula (1), expressed in mass fraction:
Where, w1 - The mass fraction of the oxides of each test element, %;
c - The concentration of each test element in the test material solution, in micrograms per milliliter (µg/mL);
c0 - The concentration of each test element in the blank solution, in micrograms per milliliter (µg/mL);
......
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 10 pages — is available in the English PDF.
Referenced standards
Normative references
GB/T 2007
How to Download SJ/T 11792-2022
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 2007.4-2008 — General rules for the sampling and sample preparation of minerals in bulk - Experimental methods for checking the precision and bias
GB/T 2007.5-1987 — [Replaced by GB/T 2007.4-2008] General rules for the sampling and sample preparation of minerals in bulk--Experimental method for checking the bias of sampling
GB/T 2007.6-1987 — General rules for the sampling and sample preparation of minerals in bulk - Determination of moisture content - Heat drying method
Secure payment via Stripe
Payments accepted
SJ/T 11792-2022
$85.00