Scope

QC/T 457-2023 (Ambulance) is available as an English-translated PDF.

QC/T 457-2023 - This Document specifies the identification, dimensions, technical requirements, inspection rules, packaging, transportation, and storage requirements for multilayer plastic fuel pipes for automobiles (hereinafter referred to as "multilayer pipe"); and describes the test methods.

This Document applies to the manufacture, inspection, sale, and use of multilayer plastic fuel pipes with an operating temperature between -40°C and +135°C, a working medium of gasoline or gasoline vapor, and a maximum operating pressure not exceeding 0.7 MPa.

This Document applies to solid-wall pipe; for corrugated pipe, refer to the relevant test methods depending on the specific operating environment.

Found what you need?

Document preview — QC/T 457-2023

National Standard of the People's Republic of China

ICS
43.060.40

Issued by: Ministry of Industry and Information Technology of the People’s Republic of China

Contents

  • Foreword...3
  • 1 Scope...6
  • 2 Normative References...6
  • 3 Terms and Definitions...6
  • 4 Identification...7
  • 5 Dimension and Specification...7
  • 6 Technical Requirements...8
  • 7 Test Methods...11
  • 8 Inspection Rules...29
  • 9 Packaging, Transportation, and Storage...30

Foreword

This Document was drafted as per the rules specified in GB/T 1.1-2020 Directives for

Standardization – Part 1.Rules for the Structure and Drafting of Standardizing Documents.

This Document replaced QC/T 798-2008 Multi-Layers Plastic Tubing for Automotive Fuel

System. Compared with QC/T 798-2008, the major technical changes of this Document are as

follows besides the structural adjustments and editorial modifications.

--- Delete the application of pipe assemblies within the scope of this Document (see Clause

1 of this Edition; Clause 1 of the 2008 Edition);

--- Change the applicable temperature range for multilayer pipes (see Clause 1 of this Edition;

Clause 1 of the 2008 Edition);

--- Add the working media (see Clause 1 of this Edition);

--- Add a reference for corrugated pipe (see Clause 1 of this Edition);

--- Delete the definition of pipe assemblies (see Clause 3 of this Edition; 3.1 of the 2008

Edition);

--- Change the definition of multilayer pipes (see Clause 3 of this Edition; 3.2 of the 2008

Edition);

--- Add the definitions of solid-wall pipe and corrugated pipe (see Clause 3 of this Edition);

--- Change the identification (see Clause 4 of this Edition; Clause 9 of the 2008 Edition);

--- Change the specifications and dimensions of multilayer pipes (see Table 1 of this Edition;

Clause 4 of the 2008 Edition);

--- Delete the general requirements (see Clause 6 of the 2008 Edition);

--- Change the technical requirements (see Table 2 of this Edition; Table 2 of the 2008

Edition);

--- Change the specimen length and quantity in the test methods (see Table 2 of this Edition;

Clause 7 of the 2008 Edition);

--- Change the test method for appearance (see 7.2 of this Edition; 7.2 of the 2008 Edition);

--- Change the test method for interlayer adhesion force (see 7.3 of this Edition; 7.11 of the

2008 Edition);

--- Change the requirements for the test tooling for yield and elongation at break (see Figure

4 of this Edition; Figure 5 of the 2008 Edition);

Multi-Layers Plastic Tubing for Automotive Fuel System

1 Scope

This Document specifies the identification, dimensions, technical requirements, inspection

rules, packaging, transportation, and storage requirements for multilayer plastic fuel pipes for

automobiles (hereinafter referred to as "multilayer pipe"); and describes the test methods.

This Document applies to the manufacture, inspection, sale, and use of multilayer plastic fuel

pipes with an operating temperature between -40°C and +135°C, a working medium of gasoline

or gasoline vapor, and a maximum operating pressure not exceeding 0.7 MPa.

This Document applies to solid-wall pipe; for corrugated pipe, refer to the relevant test methods

depending on the specific operating environment.

2 Normative References

The provisions in following documents become the essential provisions of this Document

through reference in this Document. For the dated documents, only the versions with the dates

indicated are applicable to this Document; for the undated documents, only the latest version

(including all the amendments) is applicable to this Document.

GB/T 2828.1-2012 Sampling procedures for inspection by attributes - Part 1.Sampling

schemes indexed by acceptance quality limit (AQL) for lot-by-lot inspection

GB/T 2918-2018 Plastics - Standard atmospheres for conditioning and testing

GB 18352.6-2016 Limits and measurement methods for emissions from light-duty

vehicles (CHINA 6)

GB/T 19278-2018 General terms and their definitions of thermoplastic pipes, fittings and

valves

QC/T 797 Material identification and marking of automotive plastic, rubber and

thermoplastic elastomer parts

3 Terms and Definitions

For the purposes of this Document, the terms and definitions given in GB/T 19278-2018 and

the following apply.

3.1 Multilayer pipe

The pipe whose wall is composed of two or more layers of different materials or structures.

[SOURCE. GB/T 19278-2018, 2.2.4]

3.2 Solid-wall pipe

The pipe with a uniform annular cross-section and solid walls.

[SOURCE. GB/T 19278-2018, 2.2.2]

3.3 Corrugated pipe

The pipe with a series of parallel ridges and grooves.

4 Identification

The identification on multilayer pipes shall be clear, secure, and shall not damage the

performance of the multilayer pipe. The identification information on multilayer pipes should

include the following contents; see Figure 1 for an example.

a) Specification. Generally, use nominal outer diameter × wall thickness;

b) Material. Major visible materials shall be identified in accordance with QC/T 797;

c) Production date. It shall include year, month, and day; the order and character format of

year, month, and day are not limited;

d) Others.

5 Dimension and Specification

Table 1 lists the dimensions of the multilayer pipes in this Document. The thickness and

tolerances of each layer of the multilayer pipe can be determined through negotiation between

minimum value of the test results of 5 specimens is used as the calculated initial bursting

strength at room temperature.

7.5.1.2.3 In the bursting strength test, fittings/connectors that do not affect the bursting strength

of the specimen shall be used. If the fitting/connector detaches from the specimen or bursts

before the specimen bursts, the test data is invalid. If necessary, auxiliary fixtures shall be added

to ensure the test is conducted effectively.

7.5.1.2.4 When performing tests according to the provisions of 7.7, 7.8, 7.9, 7.10, and 7.11, if

the connector detaches from the specimen or bursts before the specimen bursts or before the

required pressure level is reached, the test data is invalid. The specimen can be reused (by

inserting another fitting/connector) to avoid re-aging treatment.

7.5.2 Bursting strength at high temperature
7.5.2.1 Test apparatus

High-temperature bursting strength testing machine.

7.5.2.2 Test procedure
7.5.2.2.1 If the maximum applicable temperature for multilayer pipes is 135°C, the specimen

shall be tested at an ambient temperature and a medium temperature of 135°C±2°C. If the

maximum applicable temperature for multilayer pipes is 115°C, the specimen shall be tested at

an ambient temperature and a medium temperature of 115°C±2°C.

7.5.2.2.2 The internal test medium of the specimen is silicone oil.
7.5.2.2.3 Connect the specimen to a high-temperature bursting strength testing machine and

stabilize it for 2 h at the ambient temperature specified in 7.5.2.2.1.After heating the test

medium to the medium temperature specified in 7.5.2.2.1, pressurize the multilayer pipe at a

rate of 7 MPa/min ± 1 MPa/min until the multilayer pipe bursts. Record the maximum pressure

value of each specimen during the test as the test result.

7.5.2.2.4 In the bursting strength test, fittings/connectors that do not affect the bursting strength

of the specimen shall be used. If the fitting/connector detaches from the specimen or bursts

before the specimen bursts, the test data is invalid. If necessary, auxiliary fixtures shall be added

to ensure the test is conducted effectively.

7.6 Surface resistivity

7.6.1 Test apparatus

Ohmmeter.

Copper needle. Outer diameter of copper needle = Inner diameter of specimen ID (nominal size)

+ 0.1 mm.

7.7.2 Test method
7.7.2.1 This test should be performed according to Method I. If Method I cannot be met, Method

II shall be performed after agreement between the supplier and the purchaser, and this shall be

stated in the report.

7.7.2.2 Method I.

a) Place the specimen and impact testing apparatus in an environmental chamber at -40 °C

± 2 °C for 4 h;

b) Place the specimen in the mounting hole of specimen shown in Figure 6 in an environment

at -40 °C ± 2 °C, and then allow the impact hammer to drop.

7.7.2.3 Method II.

a) Place the specimen and impact testing apparatus in an environmental chamber at -40°C±2°C

for 4 h;

b) Remove the impact apparatus from the environment at -40°C±2°C and place it in an

environment with a temperature not exceeding 23°C;

c) Remove the specimen from the environment at -40°C±2°C and place it in the mounting

hole of specimen shown in Figure 6 within 5 s, then allow the impact hammer to drop;

d) Remove the impact apparatus from the environment at -40°C±2°C for a maximum of 3

min. During this period, multiple specimens can be conducted impact test. Near the end

of the 3 min, return the impact apparatus to the environmental chamber for at least 25

min;

e) Repeat steps b) to d) until all specimens have undergone impact test.

7.7.2.4 After the impact test, visually inspect the specimen for cracks and record the results.

Then place the specimen in a room temperature environment of 23°C±2°C to allow it to return

to room temperature.

7.7.2.5 Perform the test on the specimen according to the provisions of 7.5.1 and record the test

data.

7.7.2.6 If the specimen is a multilayer pipe with conductivity requirements, perform the test on

the specimen first according to the provisions of 7.6, and then perform the test according to the

provisions of 7.7.2.5.

7.7.2.7 If the specimen is a corrugated pipe, the impact hammer shall be dropped from a height

of 153 mm±3 mm, and the impact location shall preferably be the corrugated area.

7.8 Zinc chloride resistance

......

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 30 pages — is available in the English PDF.

Referenced standards

How to Download QC/T 457-2023

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
30 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

QC/T 457-2023

$400.00