Valid

QC/T 1061-2017Road tank vehicles for light fuel oil - Overfill prevention systems (English PDF)

道路运输轻质燃油罐式车辆 防溢流系统

Preview PDF

This is a limited preview

Buy now to download the full PDF (24 pages)

Need quotation for your management?

Get a formal quotation for QC/T 1061-2017 in 30 minutes.

Issued by

MIIT

Level / Type

Industry · Recommended

Issue date

January 9, 2017

Implementation date

July 1, 2017

Scope

QC/T 1061-2017 is the English-translated version of 道路运输轻质燃油罐式车辆 防溢流系统.

QC/T 1061-2017 covers the overfill prevention system of a road tank vehicle carrying light fuel: an optical sensor at the top of the tank joined by cable to a socket outside.

It applies where the load is diesel or light fuel oil (UN No. 1202), motor gasoline (UN No. 1203) or kerosene (UN No. 1223) of GB 12268.

Housings are to be aluminium alloy or stainless steel, not cast iron or non-metallic material, the sensor intrinsically safe to GB 3836.1 and GB 3836.4 with the mark Ex ia II B T4, its metal case at least IP 54 of GB 4208.

Tests include sealing at 36 kPa held at least 60 s, 48 h powered dry and 25 000 wet-dry cycles without short or open circuit. Issued on 9 January 2017, it has applied since 1 July 2017.

Found what you need?

Document preview — QC/T 1061-2017

National Standard of the People's Republic of China

Classification
T 50

Issued by: Ministry of Industry and Information Technology of the People's Republic of China

Contents

  • 1 Scope
  • 2 Normative references
  • 3 Terms and definitions
  • 4 Requirements
  • 5 Test methods
  • 6 Inspection rules
  • 7 Identification

1 Scope

This standard specifies the terms and definitions, requirements, test methods, Inspection rules and identification.

This standard applies to anti-overflow systems installed on road transport tank vehicles, and its transportation medium is limited to oil or light fuel oil (UN No. 1202), motor gasoline (UN No. 1203), kerosene (UN No. 1223) as defined in GB 12268.

2 Normative references

The following documents are essential for the application of this standard. For dated references, only the dated version applies to this standard. For undated references, the latest version (including all amendments) is applicable to this standard.

GB 3836.1 Electrical equipment for explosive gas environments-Part 1. General requirements for equipment

GB 3836.4 Electrical equipment for explosive gas atmospheres-Part 4. Intrinsically safe "i"

GB 4208 enclosure protection grade (IP code)

GB 12268 List of dangerous goods

3 Terms and definitions

3.1 Overfill prevention system

A system consisting of an anti-overflow sensor and an anti-overflow socket connected by a cable.

3.2 Overfill prevention optic sensor

A sensor installed at the top of the tank to determine whether the liquid level in the tank exceeds a specified height.

3.3 Overfill prevention socket

Interface for anti-overflow system and external connection.

4 Requirements

4.1 Basic requirements

4.1.1 Each component of the anti-overflow system shall meet the requirements of this standard and shall be manufactured according to the product drawings and technical documents.

4.1.2 The raw materials, purchased parts, and outsourced parts applied to each component of the anti-overflow system shall meet the requirements of relevant standards.

4.2 Materials

4.2.1 The selection of housing material and sealing material must fully consider its compatibility with the medium in contact.

4.2.2 The housing of the sensor and socket in the anti-overflow system should be made of aluminum alloy or stainless steel, and should not be made of cast iron and non-metallic materials.

4.3 Conductive resistance

The value of the static resistance between the conductive parts and the housing of the anti-overflow system components that conduct static electricity shall not be less than 10^6 ohm.

4.4 Design temperature

The design temperature of the anti-overflow sensor should be -20 °C. When there are special environmental requirements, the design temperature should be -40 °C ~ 70 °C.

4.5 Explosion-proof performance

4.5.1 The anti-overflow sensor shall be intrinsically safe and shall comply with the requirements of GB 3836.1 and GB 3836.4.

4.5.2 The explosion-proof performance shall meet the requirements of the explosion-proof mark Ex ia II B T4. The specific description is as follows.

a) Ex mark;

b) ia Intrinsically safe electrical equipment. Sparks or thermal effects generated during normal operation or under standard test conditions must not ignite explosive mixtures;

c) II Electrical equipment. Explosive environments other than coal mines;

d) B gas group. the maximum test safety clearance is 0.5 mm ~ 0.9 mm, and the minimum ignition current ratio is 0.45 ~ 0.8;

e) T4 temperature level. The maximum surface temperature of electrical equipment is 135 °C.

4.5.3 The protection level of the metal case of the anti-overflow sensor is not less than the IP 54 protection level specified in GB 4208.

4.6 Level sensing

4.6.1 When the liquid level reaches the sensing position of the anti-overflow sensor, the anti-overflow sensor shall issue a liquid level alarm.

4.6.2 When the anti-overflow sensor is in a dry state, the anti-overflow system is in a normal working state, and the liquid level replacement phenomenon must not occur.

4.7 Sealing

The test pressure is 36kPa, the holding time is at least 60s, and there must not be visible leakage at the connection between the anti-overflow sensor body and the housing.

4.8 Service life

4.8.1 When the anti-overflow sensor is in the dry state, after a continuous power-on and on-hook time of 48h, no short circuit or open circuit shall occur.

4.8.2 The anti-overflow sensor shall not be short-circuited or open-circuited after 25 000 uninterrupted tests in both wet and dry states.

4.9 External connection dimensions

The dimensions of the anti-overflow socket interface shall meet the requirements of Appendix A.

4.10 Electrical wiring

The cross-sectional area of the copper core wire of a single wire should not be less than 0.75 mm².

4.11 Contact arrangement

See Table 1 for the contact arrangement between the sensor and the six-core socket in the anti-overflow system.

5 Test methods

5.6 Anti-overflow sensor service life test

5.6.1 When the anti-overflow sensor is in the dry state, continuous power is applied, and the on-hook time is not shorter than 48 hours.

5.6.2 Place the anti-overflow sensor in the container and continuously switch between wet and dry states, and perform 25 000 continuous measurements.

After the test, there should be no damage such as short circuit or open circuit, which will make the liquid level undetectable.

5.7 Conduction resistance test

5.7.1 The anti-overflow system and its components should be dried before the test.

5.7.2 Use 500 V DC megohmmeter to measure resistance.

5.7.3 Measure the electrostatic resistance between any conductive part on the anti-overflow component that may be in contact with the medium and the case.

6 Inspection rules

6.1 Factory inspection

6.1.1 Each product shall be inspected from the factory according to the specified items, and only after passing the inspection by the manufacturer and issuing a product certificate leave the factory.

6.1.2 Factory inspection items

a) appearance;

b) level sensing test;

c) Conductive resistance.

6.2 Type test

6.2.1 Type inspection shall be carried out in any of the following cases.

a) When new products are trial-typed;

b) When it is in production, if it is produced continuously for 3 years or when the cumulative output is 10,000 units;

c) After the formal production, if the structure, material and process are changed greatly, which may affect the performance of the product;

d) When there is a significant difference between the factory inspection and the type inspection.

6.2.2 In the case of type inspection, if it is a) or b) in 6.2.1, it shall be inspected according to Chapter 4; if it is c) or d) of 6.2.1, only the affected items can be inspected.

7 Identification

7.1 Product identification

The product logo should be cast or engraved on the product body, or it should be permanently fixed on the product with a type of identification plate and clearly visible.

7.2 Anti-overflow sensor identification

The identification of the anti-overflow sensor should include at least the following.

a) manufacturer name or trademark;

b) manufacturer's model;

c) Explosion-proof mark;

d) explosion-proof certificate number;

e) production date or batch number;

f) Other working conditions that require special instructions.

7.3 Anti-overflow socket identification

The identification of the anti-overflow socket shall include at least the following.

a) manufacturer name or trademark;

b) manufacturer's model;

c) production date or batch number.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 24 pages — is available in the English PDF.

Referenced standards

Normative references

GB 3836.1 · GB 3836.4 · GB 4208

Similar standards

How to Download QC/T 1061-2017

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
24 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

QC/T 1061-2017

$205.00