Scope

QB/T 4096.24-2011 (Performance of Room Heaters for Household and Similar Purposes - Part 24: Particular Requirements for Liquid-filled Radiators) is available as an English-translated PDF.

QB/T 4096.24-2011 — This chapter of QB/T 4096-2010 is replaced by the following contents. This Part specifies the terms and definitions, product classification, requirements, testing methods, inspection rules, and marking, packaging, transportation and storage of liquid-filled radiators for household and similar purposes (hereinafter "radiators").

This Part applies to radiators – for single-phase appliances, the rated-voltage is not more than 250V; for other appliances, the rated-voltage is not more than 480V.

The radiators are used in household or similar sites.

The radiators may be of portable type, fixed type, stationary type etc. This Part does not apply to. -- the radiators installed in the structures of buildings; -- the radiators specially designed for industrial purposes; -- the radiators for the special environment where frequent use of corrosive or explosive gases (such as dust, steam or gas) is intended.

Found what you need?

Document preview — QB/T 4096.24-2011

National Standard of the People's Republic of China

ICS
97.100.10
Classification
Y 63

Issued by: Ministry of industry and information technology of the People's Republic of China 3.No action is required - Fu

Contents

  • Foreword...3
  • 1 Scope...4
  • 2 Normative References...4
  • 3 Terms and Definitions...4
  • 4 Production Classification...5
  • 5 Requirements...6
  • 6 Test methods...7
  • 7 Inspection Rules...11
  • 8 Marking, Packaging, Transportation and Storage...12
  • Appendix...13
  • Appendix AA (Informative) The Effect Sketch of Climate Laboratory...13

Foreword

QB/T 4096 is the first part of the series of standards for the performance of room

heaters for household and similar purposes; and It is the general requirements part.

This Part is QB/T 4096.24-2011, Performance of Room Heaters for Household and

Similar Purposes - Part 24.Particular Requirements for Liquid-filled Radiators.

This Part should be used together with QB/T 4096-2010, Performance of Room

Heaters for Household and Similar Purposes - Part 1.General Requirements.

This part is formed by modification or addition of QB/T 4096-2010.Where it states

"applicable", it means that the corresponding provisions in QB 4096-2010 apply to this

part; where it states "replacement", it means that the provisions in this part shall prevail;

where is states "modification", it means that the modified content of the related

provisions in the corresponding clauses of QB/T 4096-2010 shall prevail, and the rest

content of the clause is still applicable; where it states "addition", it means that the

additional provisions in this part shall, at the same time, meet the related provisions in

QB/T 4096-2010.

The additional provisions to QB/T 4096 are numbered from 101.

This Part was proposed by the China Light Industry Federation.

This Part shall be under the jurisdiction of the National Household Electrical

Standardization Technical Committee (SAC/TC46).

The responsible drafting organizations of this Part. Singfun Group Co., Ltd., Ningbo

Singfun Electrical Manufacturing Co., Ltd., Guangdong Midea Environmental Electrical

Manufacturing Co., Ltd.

The participating drafting organizations of this Part. China Institute of Electrical

Appliances, Ningbo Product Quality Supervision and Inspection Institute, China

Electrical Science Research Institute, Zhejiang Quality and Technical Supervision and

Inspection Institute, Guangzhou Vkan Certification and Testing Co. Ltd., China National

Supervision and Test Center for Infrared and Industry Galvanothermy Product Quality.

1 Scope

This chapter of QB/T 4096-2010 is replaced by the following contents.

This Part specifies the terms and definitions, product classification, requirements,

testing methods, inspection rules, and marking, packaging, transportation and storage

of liquid-filled radiators for household and similar purposes (hereinafter "radiators").

This Part applies to radiators – for single-phase appliances, the rated-voltage is not

more than 250V; for other appliances, the rated-voltage is not more than 480V. The

radiators are used in household or similar sites. The radiators may be of portable type,

fixed type, stationary type etc.

This Part does not apply to.

-- the radiators installed in the structures of buildings;

-- the radiators specially designed for industrial purposes;

-- the radiators for the special environment where frequent use of corrosive or

explosive gases (such as dust, steam or gas) is intended.

2 Normative References

This chapter of QB/T 4096-2010 applies.

3 Terms and Definitions

This chapter of QB/T 4096-2010 applies, except the following contents.

3.101

liquid-filled radiator

A device which dissipates heat through its radiating fins and/or shell after the electric

heating elements heat the liquid in the inner cavity of radiating fins.

3.101.1

oil-filled radiator

A liquid-filled radiator which dissipates heat through its radiating fins and/or shell after

the electric heating elements heat the conduction oil in the inner cavity of radiating fins.

NOTE 101 Conduction oil is a category of special oil of good thermostability, which is used for

indirect transfer of heat.

3.101.2

water-filled radiator

A liquid-filled radiator which dissipates heat through its radiating fins and/or shell after

the electric heating elements heat the water in the inner cavity of radiating fins.

3.102

steady state

The heat balance state held after the radiator has achieved the maximum temperature

without changing.

4 Production Classification

This chapter of QB/T 4096-2010 is replaced by the following contents.

4.1 The classification in accordance with the control apparatus.

-- uncontrollable radiator;

-- power-controllable radiator;

-- temperature-controllable radiator.

4.2 The classification in accordance with the installation method.

-- portable radiator;

-- stationary radiator;

-- standing radiator.

4.3 The classification in accordance with the type of liquid filled in the inner cavity of

radiating fins.

-- electric heating oil-filled radiator;

-- electric heating water-filled radiator;

The precision of the instrument for measuring time is not lower than 1% of the time

measured.

6.5 Modification.

Keep the freezing chamber at (15 ± 2)°C; set the initial temperature of the laboratory

at (15 ± 2)°C; and keep the relative humidity not greater than 85%. Stop the air

exchange between the laboratory and the freezing chamber during the test.

NOTE 101 If, within 60 s, the temperature rise is not greater than 2 K, then it is deemed the

steady state is achieved.

6.6 Replacement.

The temperature-rise time of the radiators is measured during the test of 6.101.

Measure the time required for the radiators to acquire 90% of the surface maximum

temperature under the steady state conditions, as shown in Figure 101.For the

temperature at the maximum point of the radiators' surface, the temperature acquired

in the first steady state shall be used as the reference; and the time of temperature-

rise is approximated to minute.

NOTE 101 The measuring methods and measuring points are same as that specified in 6.101.

6.101 Measurement of surface temperature

6.101.1 The radiators shall be placed in a test corner formed by two wallboards at

right angle to each other and one baseboard; and the test corner shall be made of

plywood, which is coated with matt black paint and of about 20 mm in thickness. The

specific layout is as follows.

-- for the radiators normally placed on the ground, place them as in normal use,

keeping the radiating side surface 300 mm from one wallboard and far from the

other wallboard. See Figure 102 for the radiating side surface of the radiators.

-- for the radiators normally fixed on the wall, fix them to one wallboard as in normal

use, keeping them as close to the other wallboard and baseboard as possible,

unless specified otherwise in the instructions for installation.

6.101.2 If the radiating surface of the radiators is planar or approximately planar, as

shown in Figure 103, divide the vertical center line of the radiating surface of the

radiators into four equal parts; and then arrange the thermocouples at the center points

of each equal division. Test the two planar radiating surfaces of the radiators;

meanwhile, use the temperature measuring and recording instrument to measure and

record the temperature curve (as shown in Figure 101) and temperature value from

the room temperature to the steady state of temperature. Determine the maximum

temperature of all measured surfaces when the steady state is established; use the

......

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 13 pages — is available in the English PDF.

Referenced standards

How to Download QB/T 4096.24-2011

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
13 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

QB/T 4096.24-2011

$105.00