Valid

QB/T 4096.23-2011Performance of room heaters for household and similar purposes. Part 23: Particular requirements for visibly glowing radiant heaters (English PDF)

Preview PDF

Also coversQBT4096.23-2011

This is a limited preview

Buy now to download the full PDF (9 pages)

Need quotation for your management?

Get a formal quotation for QB/T 4096.23-2011 in 30 minutes.

Issued by

Ministry of industry and information technology of the People's Republic of China 3.No action is required - Fu

Level / Type

National · Recommended

Issue date

December 20, 2011

Implementation date

July 1, 2012

Scope

QB/T 4096.23-2011 (Performance of room heaters for household and similar purposes. Part 23: Particular requirements for visibly glowing radiant heaters) is available as an English-translated PDF.

QB/T 4096.23-2011 — This chapter of QB/T 4096-2010 is replaced by the following contents.

This Part specifies the terms and definition, product classification, requirements, testing methods, inspection rules, as well as marking, packaging, transportation, storage of visibly glowing radiant heaters for household and similar purposes (hereinafter "heaters").

This part is applicable to heaters – for single-phase appliance, the rated-voltage is not more than 250V; for other appliances, the rated-voltage is not more than 480V; the heaters are used in household or similar venues.

The heaters can be portable, fixed, standing etc. This part is not applicable to. - Heaters installed in the structure of a building; - Central heating system; - Heaters connecting air ducts; - Wallpaper, blanket, curtain or tube with flexible electric heating components; - Household room heaters of thermal storage type; - Bathroom electric heater (bathroom heat lamp fixture).

Found what you need?

Document preview — QB/T 4096.23-2011

National Standard of the People's Republic of China

ICS
97.100.10

Issued by: Ministry of industry and information technology of the People's Republic of China 3.No action is required - Fu

Contents

  • Foreword...3
  • 1 Scope...4
  • 2 Normative references...4
  • 3 Terms and definitions...4
  • 4 Production classification...5
  • 5 Requirements...5
  • 6 Test methods...6
  • 7 Inspection rules...8
  • 8 Marking, packaging, transportation, storage...8
  • Appendix...9

Foreword

QB/T 4096 is the first part of the series of performance standards for household and

similar indoor heaters. It is a general requirement. This part is QB/T 4096.23-2011

Performance of room heaters for household and similar purposes - Part 23.Particular

requirements for visibly glowing radiant heaters.

This Part should be used together with QB/T 4096-2010 Performance of room heaters

for household and similar purposes - Part 1.General requirements.

This part is formed by modification or addition of QB/T 4096-2010.Where it states

"applicable", it means that the corresponding provisions in QB 4096-2010 apply to this

part; where it states "replacement", it means that the provisions in this part shall prevail;

where is states "modification", it means that the modified content of the related

provisions in the corresponding clauses of QB/T 4096-2010 shall prevail, and the rest

content of the clause is still applicable; where it states "addition", it means that the

additional provisions in this part shall, at the same time, meet the related provisions in

QB/T 4096-2010.

The additional provisions of QB/T 4096 will be numbered from 101.

This Part was proposed by the China Light Industry Federation.

This Part shall be under the jurisdiction of the National Household Electrical

Standardization Technical Committee (SAC/TC46).

Main drafting organizations of this Part. SINGFUN Group Co., Ltd., Ningbo SINGFUN

Electrical Manufacturing Co., Ltd., Guangdong Midea Environmental Electrical

Manufacturing Co., Ltd.

Drafting organizations of this Part. Shenzhen LIAN Industrial Co. Ltd., Emmett

(Shenzhen) Electric Co. Ltd., China Institute of Electrical Appliances, Ningbo Product

Quality Supervision and Inspection Institute, China Electrical Science Research

Institute, Zhejiang Quality and Technical Supervision and Inspection Institute,

Guangzhou Qi Kai Testing Technology Research Institute, National Infrared and

Industrial Electrothermal Products Quality Supervision and Inspection Center.

Main drafters of this Part. Fang Qinglian, Zhu Yongguo, Nie Yong, Ma Dejun, Tian

Hongtao, Luo Lizhen, Bao Jun, Xu Yanrong, Zhao Qi, Su Tao, Chen Yonghua, Zeng

Yu.

Performance of room heaters for household and similar purposes -

Part 22.Particular requirements for visibly glowing radiant heaters

1 Scope

This chapter of QB/T 4096-2010 is replaced by the following contents.

This Part specifies the terms and definition, product classification, requirements,

testing methods, inspection rules, as well as marking, packaging, transportation,

storage of visibly glowing radiant heaters for household and similar purposes

(hereinafter "heaters").

This part is applicable to heaters – for single-phase appliance, the rated-voltage is not

more than 250V; for other appliances, the rated-voltage is not more than 480V; the

heaters are used in household or similar venues. The heaters can be portable, fixed,

standing etc.

This part is not applicable to.

- Heaters installed in the structure of a building;

- Central heating system;

- Heaters connecting air ducts;

- Wallpaper, blanket, curtain or tube with flexible electric heating components;

- Household room heaters of thermal storage type;

- Bathroom electric heater (bathroom heat lamp fixture).

2 Normative references

This chapter of QB/T 4096-2010 is applicable.

3 Terms and definitions

This chapter of QB/T 4096-2010 is applicable except for the following content.

3.101 Steady state

work normally when the environmental temperature is (7±3) °C.

5.10 Addition

The motor is an electric motor that can implement the forced ventilation function.

5.11 Addition

The heater body rotation mechanism should be able to withstand the test of 100

thousand times continuous rotation. After the test, the body rotation mechanism can

still function normally, and the breakage of any wire of the multiple-stranded-wire that

passes through the moving parts should not exceed 10%.

Note 101.One-rotation refers to the movement -- starting from the stop position, turn

to the maximum rotation angle, then turn to the other side of maximum rotation angle,

and then turn back to the stop position.

5.101 Cold water impact of electric heating elements

Glass or ceramic electric heating elements that are likely to be splashed by water

during normal use should be able to withstand the impact test of cold water at (5±1) °C,

without blasting or other damage.

5.102 Thermal overload

The appliance should be able to withstand the 30 times of cycle thermal overload test.

After the test, the heater will not generate flame, melt or any other damage that cannot

be repaired. Meanwhile, pressure test shall be carried out immediately according to

the provisions of GB 4706.23 Chapter 16, and no breakdown or flashover shall occur.

5.103 Body rotation performance

5.103.1 The rotating mechanism of the heater body should have a switch or a device

that controls the rotation and the start/stop of the heater.

5.103.2 The rotating mechanism of the heater body should be able to automatically

and continuously rotate, requiring a smooth movement (except for the moment of start

of the rotating mechanism and reversal of rotation).

5.103.3 The rotation angle of the heater body shall not be less than 60°, and should

not be lower than the indicated value.

6 Test methods

This chapter of QB/T 4096-2010 is applicable except for the following contents.

......

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 9 pages — is available in the English PDF.

Referenced standards

How to Download QB/T 4096.23-2011

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
9 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

QB/T 4096.23-2011

$55.00