Valid

LY/T 3142-2019Technical standard for log house (English PDF)

Preview PDF

This is a limited preview

Buy now to download the full PDF (12 pages)

Need quotation for your management?

Get a formal quotation for LY/T 3142-2019 in 30 minutes.

Issued by

State Forestry and Grassland Administration

Level / Type

National · Recommended

Issue date

October 23, 2019

Implementation date

April 1, 2020

Scope

LY/T 3142-2019 (Technical standard for log house) is available as an English-translated PDF.

LY/T 3142-2019 — This standard specifies the basic rules, materials, components, protection, thermal insulation, sound insulation, construction and engineering acceptance of well-dried wood structures.

And other requirements. This standard applies to the second floor or less (excluding the attic part), the building area does not exceed 500 m2, and the building height is less than 10 m Well dry wood construction.

For well-dried timber structure buildings exceeding the number of floors, area or building height, the structural calculation should be carried out separately.

Found what you need?

Document preview — LY/T 3142-2019

National Standard of the People's Republic of China

ICS
91.080.20
Classification
P 23

Issued by: State Forestry and Grassland Administration

Contents

  • Foreword
  • 1 Scope
  • 2 Normative references
  • 3 Terms and definitions
  • 4 Materials
  • 4.1 Logs and sawn timber
  • 4.2 Laminate for structural use
  • 4.3 Metal connectors
  • 5 Yokogi
  • 5.1 Cross-section form
  • 5.2 Notch form at the end of the beam
  • 6 Basics
  • 7 Wall
  • 7.1 Cross-wood stacked form
  • 7.2 Horizontal beam connection
  • 7.3 Upper and lower crossbar seals
  • 7.3 Wall and post connection
  • 7.4 Minimum wall thickness
  • 7.5 Protruding length of crossbar end
  • 7.6 Structural Wall
  • 7.7 Strengthening pins
  • 7.8 Use of through bolts at the intersection of exterior walls
  • 9 Roof
  • 10 Antisepsis requirements and measures
  • 11 Fire retardant requirements and measures
  • 12 Thermal insulation requirements and measures
  • 13 Sound insulation requirements and measures

Foreword

This standard was drafted in accordance with the rules given in GB/T 1.1-2009.

Please note that some elements of this document may involve patents. The issuer of this document is not responsible for identifying these patents.

This standard was proposed and managed by the National Timber Standardization Technical Committee Structural Timber Subcommittee (SAC/TC41/SC4).

This standard was drafted. Institute of Wood Industry, Chinese Academy of Forestry, Dalian Fangyuan Wooden Villa Manufacturing Co., Ltd., Beijing Jiaotong University, National Center for Quality Supervision and Inspection of Wood-based Panels and Wood and Bamboo Products, National Engineering Research Center of Wood Industry, Beijing Forestry University, Torch High-tech Industrial Development Center of the Ministry of Science and Technology, Guangdong Runcheng Chuangzhan Wood Industry Co., Ltd., Manzhouli Kairun Wood Industry Co., Ltd., Dongguan Fu Lin Energy-saving Housing Technology Co., Ltd., Manzhouli Lvyuan Wooden Products Development Co., Ltd., Beijing Hyde Wooden House Co., Ltd.

1 Scope

This standard specifies the basic rules, materials, components, protection, thermal insulation, sound insulation, construction and engineering acceptance of well-dried wood structures.

And other requirements.

This standard applies to the second floor or less (excluding the attic part), the building area does not exceed 500 m2, and the building height is less than 10 m Well dry wood construction. For well-dried timber structure buildings exceeding the number of floors, area or building height, the structural calculation should be carried out separately.

2 Normative references

The following documents are essential for the application of this document. For dated references, only the dated version applies to this document.

For undated references, the latest version (including all amendments) applies to this document.

GB/T 144 Log Inspection GB/T 153 Coniferous sawn timber GB/T 700 carbon structural steel GB/T 4817 Hardwood sawnwood GB/T 5780 Hex head bolt C GB/T 5782 hexagon head bolt GB/T 6491 Drying quality of sawn timber GB/T 8484 Thermal insulation performance classification and detection methods for doors and windows of buildings GB/T 26899 Structural Laminate GB/T 27651 Classification and requirements for use of antiseptic wood GB/T 33041 Classification of terrestrial wood decay and termite hazards in China GB 50005 wood structure design standard GB/T 50083 Basic Terminology Standard for Engineering Structure Design GB 50206 Code for Construction Quality Acceptance of Timber Structure Engineering GB 50222 Code for fire protection design of building interior decoration GB/T 50353 Code for calculation of construction area LY/T 2059 Steel nails for wood structures LY/T 2383 Structural timber strength grade JGJ/T 245 Technical term for house termite prevention

3 Terms and definitions

GB/T 50083, GB/T 50353 and the following terms and definitions apply to this document.

Horizontal member horizontal member in well dry structure applications, horizontally placed wooden members are called crossbars.

Log structure

The cross-sections of circular, rectangular and other cross-sections are stacked in parallel to the upper layer.

The structure is constructed by standing pillars on the wall.

Attic

Located at the uppermost part of the building, the clearance between the sloped roof and the lower horizontal floor should be less than 2.1m. Not counting buildings here Number of layers.

Building area

Floor area of a building (including walls).

[GB/T 50353, term 2.0.1] 3.4 Building height the flat roof is calculated from the height of the building's outdoor ground to its roofing surface, and the sloped roof should be based on the flatness of the building's outdoor ground to the eaves and ridge.

Average height calculation.

Structural wall

Load-bearing walls that are mainly subjected to lateral forces or earthquakes and maintain the overall stability of the structure, also known as shear walls, seismic walls, etc.

[GB/T 50083, structural term 3.2.24] 3.6 Through bolt A metal connecting piece that runs from the foundation to the top of the wall and connects the crossbars in series.

Anchor bolt

A kind of embedded in the foundation and connecting and fixing the foundation with the first wooden beam of the foundation or the first layer of horizontal wells of the well-dry wall Metal connection.

4 Materials

4.1 Logs and sawn timber

4.1.1 Timber species are selected according to the species list in GB 50005. Timber should have the characteristics of not being easy to bend and strong in durability.

4.1.2 The material grade of logs shall reach the second and higher grades specified in GB/T 144.

4.1.3 The material grade of coniferous sawn timber should reach the second and higher grades specified in GB/T 153; the material grade of hardwood sawn timber should reach GB/T

4817 Class 2 and above.

4.1.4 For unlisted logs or sawn timber, the strength level of softwood is not lower than S18 in LY/T 2383, and the strength level of hardwood is not lower than LY/T H14 in 2383.

4.1.5 The wood moisture content of the product should be less than 20%.

4.2 Laminate for structural use

4.2.1 Timber species are selected according to the species list in GB 50005. Timber should have the characteristics of not being easy to bend and having high durability.

4.2.2 The quality level of the material surface of the product shall reach the second and higher grades specified in GB/T 26899.

5.2.3 The average shear strength of all adhesive layers of the product should not be less than 6.0MPa. For needlewood, poplar, etc. with a density of 0.5g/cm3 or density for lower broad-leaved wood, if the wood breaking rate is 100%, the average shear strength of all glue layers should not be less than 4.0MPa.

4.2.4 The product strength level should not be lower than TCT21, or TCYD18, or TCYF20 specified in GB/T 26899.

4.2.5 The wood moisture content of the product shall be less than 15%.

4.3 Metal connectors

4.3.1 The steel used for through bolts, tie bolts, anchor anchors and stiffeners should be Q235 steel that complies with the current GB/T 700 regulations.

And above.

4.3.2 Bolt materials should be in accordance with current GB/T 5780 and GB/T 5782 regulations; nail material properties should be in accordance with current LY/T 2059 Provisions.

5 Yokogi

5.1 Cross-section form

Crossbars can be made from logs, sawn timber, and structural timber. The cross-sectional form of the component should be selected in accordance with Table 2 and the cross-section dimensions should be determined based on the cross-stacked form and the effective wall thickness.

Table 2 Common cross-section forms of crossbar

Round section square section log

Sawn timber---

Set for structure

Into material

5.2 Notch form at the end of the beam

The form of the slot at the end of the beam can be selected according to Table 3. For the cross form of the wall that protrudes from the wall façade at the end of the cross-wood, Figure 3a can be used.

The sum of the dimensions of the lower groove or single-sided groove should equal 1/2 thickness or 1/2 diameter. For the wall cross form of the flush wall facade at the end of the cross beam,

Figure 3b can be used but the ends should be strengthened.

Table 3 Notch form at the end of crossbar

Saddle trough

Cheek groove

Sickle trough

Ant tank

a. The end of the beam protrudes from the wall facade Semi-ant tank Ant tank V-groove b. flush wall end

6 Basics

6.1 The lower part of a load-bearing wall shall be constructed with a foundation that can safely transmit the upper load to the ground. Independent foundations, strip foundations or rafts may be used.

basis. When an independent foundation or a strip foundation is used, the overhead layer below the ground should not be less than 450mm.

6.2 Anchor bolts should be embedded in the corners of the foundation wall, within 30 cm of the connection between the foundation beams or crossbars, and the spacing on the foundation wall should not be larger 2m.

6.3 The diameter of the anchor bolts embedded in the foundation shall not be less than 12mm. Earthquake fortification intensity of 8 degrees and above or basic wind pressure of 0.55kN/m2 and in the above areas, the anchor diameter should not be less than 20mm.

6.4 The length of the anchor bolts embedded in the foundation shall be more than 25 times the bolt diameter. If there is a layer of foundation beam under the cross beam and through bolts it is not designed to be connected to the foundation beam, and the length of the foundation anchor bolt above the foundation can connect the foundation beam with the upper layer of horizontal logs. Seismic fortification intensity 8 in areas with an air pressure of 0.55kN/m2 and above, the length of the foundation anchors above the foundation should be sufficient to connect the upper three layers of crossbars.

7 Wall

7.1 Cross-wood stacked form

The cross-wood stacking form is determined by the cross-section shape of the cross-wood. Circular cross-section arc stacking, circular cross-section arc with tenon stacking, and single cross-section square Forms such as stacking and double-tenon stacking with square cross section are shown in Table 4.

Table 4 Common stacked forms of crossbar

a. Circular cross section arc stack b. Circular cross section with tenon stacking c. Single cross-section with square cross section d. Double cross-sections with square cross section

7.2 Horizontal beam connection

The same layer of crossbar in each well dry wall should be a complete crossbar. If there is a joint, it should be reinforced and placed in a safe way for the overall structure.

Unaffected location.

7.3 Upper and lower crossbar seals

A sealing layer such as burlap felt or special rubber tape should be placed between the upper and lower crossbars and crossbars, or a seal structure should be designed to prevent uneven shrinkage and the gap formed.

7.3 Wall and post connection

In the dry structure of the first floor, if the column is used together with the wall, a height-adjustable device should be installed at the upper or lower end of the column member.

Settings, as shown in Figure 1.

a. The upper end of the column b. The lower end of the column

Figure 1 Post end device

7.4 Minimum wall thickness

In a single-story building, the overlap width of the cross-wood and cross-wood should not be less than 7cm, and the cross-sectional area should not be less than 120cm2;

The overlapping width of crossbar and crossbar should not be less than 9cm, and the cross-sectional area of crossbar should not be less than 150cm2.

7.5 Protruding length of crossbar end

The elevation of the wall at the corners of the two walls protruding from the wall should not be less than 20cm, as shown in Figure 2. When the corner of the wall is compared to this document when the structural design requirements are further strengthened, the length of the protruding portion can be appropriately reduced, as shown in Figure 3.

Figure 2 Wall cross form protruding from wall end

Figure 3 The wall cross form of the flush wall at the end of the cross beam

7.6 Structural Wall

7.6.1 Structural wall settings

Load bearing on each axis in the transverse and depth directions in areas with seismic fortification intensity of 8 degrees and above or basic wind pressure of 0.55 kN/m2 and above the wall shall be constructed in whole or in part as a structural wall. The structural walls of each axis in the horizontal or depth direction shall be balanced. The ability of structural walls to resist horizontal effects Force can be achieved by installing reinforcing pins or tie bolts through the wall in the length direction. If reinforced pins are used, determine the ends in accordance with Section 7.7.

The horizontal force on the facet is used to calculate the required number of reinforcement pins and arrange them on each structural face; if adjustable the distance between the through bolt and the corner of the wall should not be greater than 800mm, the distance between the tie bolts should not be greater than 2m, and the diameter should not be less than 12mm.

7.6.2 Structural wall width and height

The corners of the wall are counted from the end of the crossbar. The width of the structural wall in the horizontal and vertical directions should be greater than 0.3 times the height of the wall, as shown in Figure 4.

For walls with discontinuities such as window openings and door openings, the width of each structural wall should be greater than 0.3 times the wall height, as shown in Figure 5.

Figure 4 Structural Wall Width at Corner

Figure 5 Structural wall width of each segment of discontinuous wall

7.6.3 Structural wall height

The height of the structural wall of a single-story dry building should not be greater than 4m (counting from the foundation to the highest of the structural walls connected to the roof) the total height of the two-story structural wall should not be greater than 6m, as shown in Figure 6.

Figure 6 Structural wall height

7.6.4 Distance between structural walls

Among the four structural walls forming the enclosed space on each floor of the building, the center distance of the parallel structural walls should not be greater than 6m, and the level of the enclosed part is horizontal the projected area should not be larger than 30m2, as shown in Figure 7. If the center distance and the horizontal projection area exceed the specified values, it should be ensured according to the structural calculation.

Its structural safety.

Figure 7 Center distance and horizontal projected area of structural wall

7.7 Strengthening pins

7.7.1 Steel pins or wood pins can be used as the reinforcement pins. The diameter of the steel pin should not be less than 9mm. The type shown in Figure 8 can be selected. Selection of Wooden Pins and Tree Species Consistent wood, without obvious defects, its minimum diameter or minimum cross-section size should not be less than 25mm, the type shown in Figure 9 can be selected.

Figure 8 Steel pin

Figure 9 Wooden pin

7.7.2 The control of the total number of pins in the structural wall of each axis in the horizontal and depth directions of the dry-type wooden structure building shall be based on the horizontal force of the axis and the total number of pins.

The principle of shear resistance ratio is less than 1.

7.7.3 Reinforcement pins shall be arranged upside down in the structural wall, and the horizontal interval shall be controlled within the range of 45-150cm.

7.7.4 The depth of the reinforcing pin in the cross beam should be greater than half of the cross section height. The number of upper and lower cross beam members connected by each pin should not exceed 3 , As shown in Figure 10. The two should be connected in an interference fit.

Figure 10 Pin usage

7.7.5 In addition to resisting horizontal shear forces, the use of pins can reduce shrinkage deformation at the ends of the wall.

7.7.6 When two or more horizontal beams are stacked to form a beam member, they shall be connected together by pins at or near the mid-span position.

7.8 Use of through bolts at the intersection of exterior walls

7.8.1 The center of the intersection of external walls or within 45cm from the center of the cross shall use a through bolt with a diameter of not less than 12mm, as shown in the figure 11-13. In areas with seismic fortification intensity of 8 degrees and above or basic wind pressure of 0.55kN/m2 and above, the diameter should be not less than 20mm Through bolts.

Figure 11 Arrangement of through bolts in the building plane

Figure 12 Position of through bolts at the intersection of exterior walls

a. Top structure

b. bottom structure

Figure 13 Application structure of through bolt

7.8.2 The remaining height of the wall above the door and window openings of the structural wall in the same layer shall be greater than 1/5 of the width of the opening, and shall be more than 30cm. Crossbar in the hole There should be no connection in the area directly above the mouth. Around the opening, reinforcements such as through bolts, stiffeners, and T-shaped sheets should be used for reinforcement.

8th floor ground

Foundation

8.1 The floor cover shall be connected with the wall joist and the wall by means of metal beam support and wooden support. The structure can refer to Figure 14. Floor joist spacing is not greater than at 610mm, floor slabs can be laid directly on the joists; for floor joists with a spacing greater than 610mm, thin beams should be installed on the joists above Laying floor slabs. The thickness of the floor slab should be determined according to the joist spacing of the floor and the design load on the floor. The minimum thickness should not be less than 12mm. for to obtain a good sound insulation effect on the floor, an acoustic insulation layer can be added between the joists.

a. The floor is connected to the external wall (beam support connection) b. Floor cover and beam connection (beam support connection) c. The floor is connected to the beam (placed on the beam) d. Floor cover and external wall connection (wooden support) e. Floor cover and beam connection (wooden support)

Figure 14 Floor structure

8.2 Floor joists should avoid openings as much as possible. The joists around the staircase opening should be strengthened.

8.3 The floor and surrounding walls of the toilet shall be waterproofed within 1.5m.

9 Roof

9.1 Each purlin in the roof shall be connected with the slidable metal connecting piece at the upper end of the wall. In order to improve the wind resistance, the wall the upper 4 or more crossbars are pulled up and down and connected to the roof, as shown in Figure 15.

Figure 15 Connection method of roof and wall

9.2 For roof trusses, the four structural forms in Table 5 can be selected. For the case where the roof truss needs to resist strong horizontal shear force, the d form should be selected, and Fasten the walls together with pins.

Table 5 Structural form of roof truss

abcd

10 Antisepsis requirements and measures

10.1 The upper horizontal beams and wooden pins that have been in a humid environment for a long time should be effectively treated.

For new sections produced during construction, equivalent preservatives should be applied. China's terrestrial wood decay and termite hazard classifications are divided according to GB/T 33041 it is stipulated that the anticorrosive grade is in accordance with GB/T 27651.

Table 6 Anti-corrosion requirements for cross beams

Hazard of wood decay on outdoor ground, etc.

Class area

Anticorrosive grade

As shown in Figure 16, when the position 300 mm above the horizontal when it is 1000mm, the wooden member within the base level and 300mm above;

When the position 300 mm above the foundation level is less than 1000 mm from the foundation, Wooden members within 1000mm above the foundation in contact with the ground, blocks or concrete D1 C3.1 C4.1 D2 C3.2 C4.2 D3 C3.2 C4.2

Table 7 Termite anti-term requirements

Wood Termite Hazard Level Area Insect level as shown in Figure 16, when the position above the ground level is 300 mm above the ground, when it is 1000mm, the wooden member within the base level and 300mm above;

When the position 300 mm above the base level is less than 1000 mm from the ground, Wooden members within 1000mm above the ground in contact with the ground, blocks or concrete T1 C3.1 C4.1 T2 C3.2 C4.2 T3 C3.2 C4.2

Figure 16 Anticorrosive treatment

10.2 For areas where termites are severely damaged, the soil around the foundation should be treated with termite prevention.

10.3 The foundation beam platform or the first layer of crossbars above the foundation shall not directly contact the concrete foundation, and shall be separated by waterproof coils or rubber pads.

10.4 Metal connectors shall be anti-corrosive treated with anti-rust paint, hot plating or electroplating.

10.5 The roof should be sloped, and the eaves should protrude more than 60cm from the wall, as shown in Figure 16. Projections on exterior walls, such as windowsills, balconies Wait for flooding.

11 Fire retardant requirements and measures

11.1 If the combustion performance of the wall is required to be a non-combustible body, fire-resistant gypsum board shall be installed or cross-bars treated with flame retardant shall be used. If fire gypsum board is laid, the horizontal logs in the wall can be treated without flame retardant, as shown in Figure 17. The fire resistance limit of the wall should be at least 1 layer on both sides of the wall.

12mm and above fire-resistant gypsum board. Plasterboard laying walls should adopt special connections to avoid vertical deformation differences between wood and plasterboard.

11.2 Beams and load-bearing columns in well dry buildings may not be flame-retardant treated, but shall meet the fire resistance limit required by the design.

11.3 The inside of the building (house) cover shall be provided with horizontal fire separation, and fire connection shall be provided at the connection with the corner of the wall.

11.4 When wires and cables pass through walls and buildings (houses), metal sleeves should be worn, and fire-blocking materials should be used to seal their gaps.

Management.

Figure 17 Typical fire protection structure of wall

12 Thermal insulation requirements and measures

12.1 In severe cold and cold areas, the ground floor shall be treated with heat insulation, and the thickness of the heat insulation material shall be determined in accordance with the actual requirements.

12.2 The thermal insulation of the external wall can adopt three methods of solid wall, external thermal insulation and internal thermal insulation, as shown in Figure 18. Wall with insulation the material and thickness should be determined according to the target energy saving requirements.

a. solid external wall b. external thermal insulation external wall c. internal thermal insulation external wall

Figure 18 Wall insulation structure

12.3 The gaps between windows and walls shall be filled and sealed with flexible thermal insulation materials, and lateral and vertical cover seams shall be nailed externally, as shown in Figure 19.

Show. Well dry-type wooden structure buildings shall use external windows with high thermal resistance, and the heat transfer coefficient shall reach level 5 and above specified in GB/T 8484.

Figure 19 Wall and window structure

12.4 The gaps between the outer door and the wall shall be filled and sealed with polyurethane foam material, and the heat transfer coefficient shall be in the 5th grade specified in GB/T 8484 and the above.

12.5 The roof shall be heat-insulated. Refer to Figure 20 for the structure. For flat roofs, thermal insulation should be placed between the joists of the roof Floor. If there is no direct contact between the top of the external wall and the roof slab, a sealing plate should be installed on the outside or the top of the external wall, and the heat insulation layer should be laid to the external wall.

Close the sealing plate above the uppermost horizontal beam. For sloping roofs, if a suspended ceiling is not used because of the increase in the upper space of the room, the thermal insulation layer should be it is placed between the joists of the roof and laid on the top wall of the outer wall to seal the baffle. For example, the Leave the ventilation channel, and the upper part of the heat insulation layer should be close to it to lay a waterproof and breathable membrane.

Figure 20 Roof insulation measures

13 Sound insulation requirements and measures

13.1 In the same building, where there is a requirement for sound insulation between rooms or floors, the wall and floor structure shall be designed for sound insulation.

13.2 Floor Sound Insulation Materials can be added to the joist floor space, as shown in Figure 14. The type and thickness of sound insulation materials shall be based on design documents.

In order...

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 12 pages — is available in the English PDF.

Referenced standards

How to Download LY/T 3142-2019

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
12 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

LY/T 3142-2019

$394.00