LY/T 1612-2023 is the English-translated version of 甲醛检测用1m3气候箱.

LY/T 1612-2023 — This document specifies the basic structure and technical parameters of a 1m3 climate chamber for formaldehyde emission testing. This document is applicable to the formaldehyde emission test of artificial boards and their products for interior decoration specified in GB 18580-2017. 1m3 climate chamber.

Found what you need?

Document preview — LY/T 1612-2023

National Standard of the People's Republic of China

ICS
79.060.01
Classification
B 70

Issued by: State Forestry and Grassland Administration

Contents

  • Foreword
  • 1 Scope
  • 2 Normative references
  • 3 Terms and definitions
  • 4 Climate Chamber Composition and Technical Parameters
  • 4.1 Climate Chamber Composition

Foreword

This document is in accordance with the provisions of GB/T 1.1-2020 "Guidelines for standardization work Part 1: Structure and drafting rules for standardization documents" Drafting.

This document replaces LY/T 1612-2004 "1m3 Climate Chamber for Formaldehyde Emission Detection".

In addition to structural adjustments and editorial changes, the main technical changes are as follows.

--- Changed the volume of the climate chamber from "volume. (1.0 ± 0.02) m3" to "effective volume. (1.0 ± 0.01) m3" (see 4.2, 2004 3.2 of the 2011 edition);

--- Changed the temperature adjustable range from "Temperature. adjustable range 20°C~25°C, accuracy ±0.5°C" to "Temperature. adjustable range Range 18°C~30°C, deviation ±1°C, uniformity 1.0°C, fluctuation ±0.3°C" (see 4.2, 3.2 of the 2004 edition);

--- Changed the relative humidity adjustable range from "relative humidity adjustable range. 45%~50%, accuracy ±3%" to "relative humidity Degree. Adjustment range 40%~60%, deviation ±3%, uniformity 3%, fluctuation ±2%" (see 4.2, 3.2 of the 2004 edition);

--- Changed the air flow rate from "air flow rate. 0.1m/s~0.3m/s, accuracy ±0.05m/s" to "carrier gas flow rate. adjust Range 0.1m/s~0.5m/s" (see 4.2, 3.2 of the 2004 edition);

--- Changed the air replacement rate from "air replacement rate. (1.0±0.05)h-1" to "carrier gas replacement rate. adjustment range (0.2~ 2.0)h-1, allowable deviation ±3%" (see 4.2, 3.2 of the 2004 edition).

--- Changed the airtightness requirements (see 5.4, 4.4 of the 2004 edition), changed the airtightness test method (see 5.4, 5.7);

--- Deleted the insulation requirements (see 4.5 and 5.6 of the 2004 edition), and added the requirements for condensation on the inner surface (see 5.5);

--- Changed the noise requirements for the climate chamber during operation, the noise value was reduced from 70dB to 60dB (see 5.6, 4.6 of the 2004 edition);

--- Changed the continuous working time requirements of the climate chamber, and the continuous stable working time was increased from 28d to 30d (see 5.7, 2004 edition 4.7);

--- Added refrigeration mode for climate control in the box (see 5.9, 4.9 of the 2004 edition);

--- Deleted the entire content of "Test Methods" (see Chapter 5 of the 2004 edition).

1 Scope

This document specifies the basic structure and technical parameters of a 1m3 climate chamber for formaldehyde emission testing.

This document is applicable to the formaldehyde emission test of artificial boards and their products for interior decoration specified in GB 18580-2017.

1m3 climate chamber.

2 Normative references

The contents of the following documents constitute the essential clauses of this document through normative references in this document.

For referenced documents without a date, only the version corresponding to that date applies to this document; for referenced documents without a date, the latest version (including all amendments) applies to this document.

GB 18580-2017 Limits of formaldehyde emission from artificial boards and their products for interior decoration and renovation JB/T 9512-2018 Determination of the sound power level of emitted noise of climate environment test equipment by sound pressure method JJF(Building Materials)182-2021 Calibration Specification for Environmental Test Chambers for Volatile Detection of Building Materials Products JJF1101-2019 Calibration specification for temperature and humidity parameters of environmental test equipment

3 Terms and definitions

There are no terms or definitions that require definition in this document.

4 Climate Chamber Composition and Technical Parameters

4.1 Climate Chamber Composition

The climate chamber usually consists of a carrier gas supply device, a carrier gas purification device, a gas flow control device, a carrier gas temperature control device, a carrier gas humidity control device, and a carrier gas temperature control device.

Device, climate chamber body, gas circulation control device in the chamber, temperature, humidity and wind speed sensors and monitoring and recording devices, mixed gas outlet, gas the sampling connection device and the sample rack are composed of a 1m3 climate chamber. See Figure 1 for a schematic diagram of the composition and Appendix A for a simplified structural diagram.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 7 pages — is available in the English PDF.

Referenced standards

How to Download LY/T 1612-2023

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
7 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

LY/T 1612-2023

$154.00