Scope
JY/T 0432-2011 (Glass instrument suction tube for teaching) is available as an English-translated PDF.
JY/T 0432-2011 - This standard specifies the classification and nomenclature of exhaust pipes, technical requirements, test methods, inspection rules, packaging, transportation, and storage. This standard applies to teaching exhaust pipes.
Found what you need?
Document preview — JY/T 0432-2011
National Standard of the People's Republic of China
- ICS
- 03.180
- Classification
- Y51
Issued by: Ministry of Education of the People's Republic of China
Contents
- Foreword
- 1 Scope
- 2 Normative references
- 3 Model designation
- 3.1 Model Nomenclature
- 3.2 Model Nomenclature
- 4 Requirements
- 4.1 Materials
- 4.2 Dimensions
- 4.3 Appearance
- 4.4 Uniformity of wall thickness
- 4.5 Chemical stability
- 4.6 Internal stress
- 4.7 Extraction ultimate vacuum
- 4.8 Environmental test
- 5 Test method
- 6 Inspection rules
- 6.1 Inspection classification
- 6.2 Inspection items and inspection methods
- 6.1 Stacking B--
- 6.2 Vibration A--
- 6.3 Free fall A--
- 6.3 Lot rules and sampling methods
- 6.4 Non-conformance determination
- 6.5 Review rules
- 6.6 Quality supervision inspection
- 7 Marking, packaging, transportation and storage
- 7.1 Signs
- 7.2 Packaging, transportation and storage
Foreword
This standard was drafted in accordance with the rules given in GB/T 1.1-2009.
Please note that some elements of this standard may involve patents. The issuer of this standard should not be held responsible for identifying these patents.
This standard was proposed by the National Technical Committee for Standardization of Teaching Instruments (SAC/TC125).
This standard is under the jurisdiction of the National Technical Committee for Standardization of Teaching Instruments (SAC/TC125).
This standard was drafted. Sichuan Longchang Glass Instrument Factory, Zhejiang Educational Technology Center, Sichuan Ziyang Glass Instrument Factory, Sichuan Scientific industry teaching equipment limited liability company.
1 Scope
This standard specifies the classification and nomenclature of exhaust pipes, technical requirements, test methods, inspection rules, packaging, transportation, and storage.
This standard applies to teaching exhaust pipes.
2 Normative references
The following documents are essential for the application of this document. For dated references, only the dated version applies to this document.
For undated references, the latest version (including all amendments) applies to this document.
GB 191-2008 packaging storage and transportation pictogram GB/T 2828.1-2003 Counting sampling acceptance procedure Part 1. Sampling plan for batch inspection for retrieval by acceptance quality limit (AQL) JY 0001-2003 General quality requirements for teaching instruments and equipment products JY 0002 Inspection rules for teaching instruments and equipment products JY 0026-1991 teaching instrument and teaching equipment product model naming method JY/T 0423-2011 General quality requirements and test methods of teaching glass instruments
3 Model designation
3.1 Model Nomenclature
The model name of the product is in accordance with the provisions of JY 0026-1991.
3.2 Model Nomenclature
The model of the exhaust pipe is named.
L - CQG - F - 350
Product specifications, unit. mm Product feature code with check valve Product name Pinyin prefix, exhaust pipe Product model classification code, glass instrument Model example.
L-CQG-F-350. 350 mm length suction pipe with check valve.
4 Requirements
4.1 Materials
It should be made of colorless transparent borosilicate glass. The average linear thermal expansion coefficient is not more than 4.0 x 10-6K-1.
4.2 Dimensions
The external dimensions and tolerances of the suction pipe shall conform to Figure 1.
Figure 1 Suction tube
4.3 Appearance
4.3.1 Permissible appearance defects. the maximum diameter of the nodules should be no more than 1mm and no more than 3; the maximum diameter of the stones should be no more than 0.5mm.
1; total allowed should not be more than 3.
4.3.2 The appearance defects that should not exist shall be in accordance with JY/T 0423-2011 Section 5.1.1.
4.3.3 The inner and outer pipes of the suction pipe shall be on the same axis, and the nozzle of the inner pipe is aligned with the lower nozzle.
4.3.4 The inner pipe mouth is ground flat, and there should be no oblique mouth and notch. The frosted float valve in the branch pipe should be flexible to prevent the gas from flowing out. Test method According to Article 5.3.
4.4 Uniformity of wall thickness
The uniformity of the wall thickness shall be in accordance with JY/T 0423-2011 Section 4.1.1.2.
4.5 Chemical stability
It should meet the water resistance HGB level 1, acid resistance H1 level, and alkali resistance A2 level.
4.6 Internal stress
The internal stress should not be greater than 180nm/cm.
4.7 Extraction ultimate vacuum
The ultimate vacuum degree of extraction is not more than 1kPa.
4.8 Environmental test
The environmental test shall be in accordance with Chapter 8 of JY/T 0423-2011.
5 Test method
5.1 The average linear thermal expansion coefficient shall be in accordance with JY/T 0423-2011 Section 6.4.2. The test shall meet the requirements of 4.1 of this standard.
5.2 Dimensions are measured with a vernier caliper with a division value of 0.02 mm and a steel ruler with a division value of 0.5 mm, which shall meet the requirements of 4.2 of this standard.
begging. The length of the appearance defects shall be tested with a reading microscope and shall comply with the corresponding requirements of this standard.
5.3 Use a medium-sized ear wash ball to connect the exhaust pipe branch, squeeze and relax the ear wash ball. The frosted float valve can only allow gas to enter, but not go out.
5.4 Pipe wall thickness and average tolerance shall be tested in accordance with JY/T 0423-2011 Section 4.1.3 and shall comply with the requirements of 4.2 and 4.4 of this standard.
5.5 Water resistance, acid resistance, and alkali resistance The test according to JY/T 0423-2011 Section 6.5.5 shall meet the requirements of 4.5 of this standard.
5.6 The internal stress shall be in accordance with JY/T 0423-2011 Section 6.1.2 and shall comply with this standard 4.6.
5.7 Connect the upper end of the suction pipe to the tap with a suitable rubber pipe. The water pressure should not be less than 0.4MPa. Use the side branch of the suction pipe an appropriate rubber tube is connected to the U-shaped mercury pressure gauge. Turn on the tap to drain water and observe that the vacuum limit of the U-type mercury pressure gauge should meet the Requirements of 4.7 of this standard.
5.8 The other sensory tests shall meet the corresponding requirements of this standard.
5.9 The environmental test shall be in accordance with Chapter 8 of JY/T 0423-2011 and shall comply with this standard 4.8.
6 Inspection rules
6.1 Inspection classification
The inspection of this product is divided into factory inspection, type test and quality supervision inspection.
6.2 Inspection items and inspection methods
The inspection items and inspection methods for factory inspection and type inspection shall conform to Table 1.
Table 1 Inspection items and inspection methods for defect classification, factory inspection and type inspection
No. Inspection Content Defect Classification Factory Inspection Type Inspection
1 Geometry and fit
1.1 Dimension A -
1.2 Wall thickness (including uniformity) B -2 appearance requirements
2.1 Appearance defect B -
2.2 Color C -
Oral treatment (external and internal suction tubes should be in the same Axis, the inner nozzle is aligned with the lower nozzle.) -
3 Physical and chemical properties
3.1 Internal stress A -
3.2 Chemical stability B--
4 Ultimate Vacuum A -
Table 1 Inspection items and inspection methods (continued)
No. Inspection Content Defect Classification Factory Inspection Type Inspection
5 Material A--
6 Environmental test
6.1 Stacking B--
6.2 Vibration A--
6.3 Free fall A--
Note. "-" in the table means full inspection for batch products, "-" means sample inspection for batch products, and "-" means no inspection.
6.3 Lot rules and sampling methods
6.3.1 The factory inspection shall be based on the natural batch of delivery, and the type inspection shall be based on the inventory array.
6.3.2 When leaving the factory, all the inspection items should be inspected first, and then samples should be taken from the qualified products of all inspection items.
test.
6.3.3 The samples for type inspection shall be taken from the products that passed the factory inspection.
6.3.4 The sampling methods for factory inspection and type inspection shall be in accordance with GB/T 2828.1-2003, and the inspection plan shall be a normal sampling once. The inspection level is General II.
6.4 Non-conformance determination
6.4.1 The classification of defects A, B and C shall conform to Table 3.
6.4.2 The criteria for a single sample shall be in accordance with Table 2.
Table 2 Single sample determination rules
Classification A defect B defect C defect Pass 0 <= 2 <= 4 Unqualified >=1 > 2 > 4
6.4.3 The quality of the inspection lot shall be determined in accordance with GB/T 2828.1-2003, a normal sampling once inspection plan, AQL value. internal stress and ultimate vacuum Take 1.5, take the external dimensions 6.5, and take the rest 2.5.
6.5 Review rules
The re-inspection shall implement the transfer rules in accordance with GB/T 2828.1-2003.
6.6 Quality supervision inspection
Press JY 0002.
7 Marking, packaging, transportation and storage
7.1 Signs
Should comply with the provisions of Chapter 11 of JY 0001-2003.
7.2 Packaging, transportation and storage
7.2.1 It shall comply with the provisions of Chapter 12 of JY 0001-2003.
7.2.2 The products shall be separated by earthquake-resistant packaging materials and fixed in the packing box.
7.2.3 The outer packaging box shall be provided with a "fragile article" pictogram in accordance with GB 191-2008.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 5 pages — is available in the English PDF.
Referenced standards
How to Download JY/T 0432-2011
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
JY/T 0663-2026 — Framework for Chinese adolescent reading literacy
JY/T 0660-2025 — Accreditation criteria for excellent engineers education
JY/T 0616-2023 — Specifications for fire safety management of laboratories in colleges and universities
Secure payment via Stripe
Payments accepted
JY/T 0432-2011
$164.00