Scope

JJG 986-2004 is the English-translated version of 木材含水率测量仪检定规程.

JJG 986-2004 - This standard applies to the moisture content of wood and products of wood moisture measurement measuring instrument (hereinafter referred to as measuring instrument) of the initial verification, testing and use of follow-up inspection.

Found what you need?

Document preview — JJG 986-2004

National Standard of the People's Republic of China

ICS
17

Contents

  • 1 Scope (1)
  • 2 Overview (1)
  • 3 Metrological performance requirements (1)
  • 3.1 Measuring instrument accuracy level (1)
  • 3.2 Measuring instrument stability (1)
  • 4 General technical requirements (2)
  • 4.1 Appearance (2)
  • 4.2 Safety requirements (2)
  • 5 Measuring instrument control (2)
  • 5.1 Verification conditions (2)
  • 5.2 Verification project (3)
  • 5.3 Verification method (3)
  • 5.4 Processing of verification results (4)
  • 5.5 Verification cycle (4)
  • Appendix A Wood Moisture Meter Verification Record (5)
  • Appendix B Air relative humidity table above saturated salt solution and its production method (6)
  • Appendix C Technical Requirements for Wood Samples (7)
  • Appendix D Verification Certificate (Back) Format (8)
  • Appendix E Verification Result Notice (Back) Format (9)

1 Scope (1)

2 Overview (1)

3 Metrological performance requirements (1)

3.1 Measuring instrument accuracy level (1)

3.2 Measuring instrument stability (1)

4 General technical requirements (2)

4.1 Appearance (2)

4.2 Safety requirements (2)

5 Measuring instrument control (2)

5.1 Verification conditions (2)

5.2 Verification project (3)

5.3 Verification method (3)

5.4 Processing of verification results (4)

5.5 Verification cycle (4)

Appendix A Wood Moisture Meter Verification Record (5)

Appendix B Air relative humidity table above saturated salt solution and its production method (6)

Appendix C Technical Requirements for Wood Samples (7)

Appendix D Verification Certificate (Back) Format (8)

Appendix E Verification Result Notice (Back) Format (9)

Wood moisture meter test procedures

1 Scope

This procedure is applicable to wood moisture meter for measuring the moisture content of wood and its products (hereinafter referred to as measurement).

The first test, subsequent verification and in-use test of the instrument.

2 Overview

The meter is mainly used to quickly detect the moisture content in wood, wood products and artificial boards. Measuring instrument according to the principle area Points, mainly resistance and capacitance methods. The electric resistance measuring instrument converts the moisture content in the wood through the probe and related circuits.

It is replaced by an electrical signal, and then by the conversion of the electrical signal, the meter indicates the measured value. Capacitance measuring instrument is to contain wood the change of the dielectric constant of the capacitor caused by the change of water rate is converted into an electrical signal by the measuring circuit, and then converted, the meter displays the measured value.

3 Metrological performance requirements 3.1 gauge accuracy level the indication error is expressed in absolute error. The meter can be divided into three grades according to the indication error, as shown in Table 1.

Table 1 Instrument indication tolerance

Accuracy level indication maximum allowable error /% 1.0 level ± 1.0 2.0 level ± 2.0

5.0 Level* ±5.0

The meter shall comply with the requirements of Table 1 within the range of 6% to 28% moisture content.

The 5.0 level* measuring instrument refers to a measuring instrument that does not specify the type of material or the moisture content of the poplar wood, and any one of them is seeded.

The indication error of the degree shall not exceed ±5.0%. The measuring instrument with the moisture content of poplar shall not exceed the indication error ±2.0%.

3.2 Measuring instrument stability Under the test of environmental conditions, when the power supply voltage changes by 10%, the error caused by the change of indication value, in the moisture content the range of 6%~28% should meet the requirements of Table 2.

Table 2 Instrument Stability Requirements

Accuracy level reading maximum change value /% 1.0 level ± 1.0 2.0 level ± 2.0 5.0 ± 2.0

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 9 pages — is available in the English PDF.

Referenced standards

How to Download JJG 986-2004

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Fast delivery

    After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
9 pages
Fast delivery
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

JJG 986-2004

$145.00