JJG 1036-2008Verification Regulation for Electronic Balance (English PDF)
This is a limited preview
Buy now to download the full PDF (20 pages)
Need quotation for your management?
Get a formal quotation for JJG 1036-2008 in 30 minutes.
Issued by
General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China 3.N
Level / Type
National · Mandatory
Issue date
February 20, 2008
Implementation date
May 20, 2008
Scope
JJG 1036-2008 (Verification Regulation for Electronic Balance) is available as an English-translated PDF.
JJG 1036-2008 is the Chinese standard "Verification Regulation for Electronic Balance". Its scope clause reads: This regulation applies to the first verification, follow-up verification, and verification in use of the electronic balance (hereinafter referred to as the balance).
Its clauses include references; terms and units of measurement; overview; measurement performance requirements. It was issued by the General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China 3.N on 2008-02-20 and took effect on 2008-05-20.
Found what you need?
Document preview — JJG 1036-2008
National Standard of the People's Republic of China
Issued by: General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China 3.N
Contents
- Verification regulation for electronic balance...4
- 1 Scope...4
- 2 References...4
- 3 Terms and units of measurement...4
- 3.1 Terms...4
- 3.2 Units of measurement...5
- 4 Overview...5
- 5 Measurement performance requirements...5
- 5.1 Actual interval value (d)...5
- 5.2 Verification interval value (e)...5
- 5.3 Verification interval number (n)...5
- 5.4 Accuracy level...6
- 5.5 Maximum permissible error (MPE)...7
- 6 General technical requirements...8
- 6.1 Appearance requirements...8
- 6.2 General requirements of structure...9
- 6.3 Indication of weighing results...11
- 6.4 Level indicator...12
- 6.5 Zero-setting device...12
- 6.6 Zero-tracking device...12
- 6.7 Tare device...12
- 7 Measurement device control...12
- 7.1 Verification conditions...12
- 7.2 Verification items...14
- 7.3 Verification method...14
- 7.4 Processing of verification results...16
- 7.5 Verification period...16
- Appendix A Electronic balance verification record format...17
- Appendix B Electronic balance verification certificate inside page format...19
- Appendix C Electronic balance verification result notice inside page format.20
1 Scope
This regulation applies to the first verification, follow-up verification, and verification in use of the electronic balance (hereinafter referred to as the balance).
2 References
This regulation adopts the relevant contents of the international recommendations R76 Non-automatic weighing instruments of the
International Organization Legal Metrology (OIML) from the aspects of measurement performance requirements and key technical indicators.
When using this regulation, care shall be taken to use the current valid version of the aforementioned references.
3 Terms and units of measurement
3.1 Terms
3.1.1 Zero-setting device. It refers to the device which sets the indication value
to zero when there is no load on the scale pan.
3.1.2 Zero-tracking device. It refers to the device which automatically maintain
the zero indication value within a certain limit.
3.1.3 Tare device. It refers to the device which sets the indication value to zero when there is load on the scale pan.
3.1.4 Multiple range. There are two or more weighing ranges, which have different maximum capacity and different actual intervals, AND each weighing range can be from zero to the corresponding maximum capacity.
3.1.5 Multi-interval. There is only one weighing range, which is divided into several local weighing ranges in accordance with different actual intervals. The local weighing range is automatically determined based on the increase or decrease in the load applied.
3.1.6 Maximum capacity. It refers to the maximum weighing capacity excluding
the added tare weight.
3.1.7 Minimum capacity. It refers to the load value below which an excessive
relative error may be caused.
3.1.8 Weighing range. It refers to the range between the minimum capacity
and the maximum capacity.
3.2 Units of measurement
The units of measurement are kilograms (kg), grams (g), milligrams (mg), micrograms (µg), and tons (t).
4 Overview
The electronic balance is a metering device which determines the mass of the object by the gravity acting on the object, AND indicates the output result by the use of numerical values. It is used for weight mass value transfer, object mass measurement, volume measurement, and magnetic measurement. It can also be used to determine other magnitudes, quantity, parameters, or characteristics related to mass.
5 Measurement performance requirements
5.1 Actual interval value (d)
It refers to the difference between the two adjacent indication values.
5.2 Verification interval value (e)
It refers to the value which is used for balance grade division and metrological verification AND expressed in mass unit. The verification interval value e is selected by the manufacturer in accordance with the requirements of Table 1.
5.2.1 Verification interval value e may be in the form as followings.
1 × 10k OR 2 × 10k OR 5 × 10k
Wherein k is a positive integer, a negative integer or zero.
5.2.2 Verification interval value e is defined by.
d <= e <= 10d
In general, the verification interval value e shall also be subject to e = 10k kg, where k is a positive integer, a negative integer or zero.
5.3 Verification interval number (n)
The ratio of the maximum capacity to the verification interval value, n = Max/e.
f) Marking of the certificate for measurement instrument manufacture;
g) Maximum capacity. expressed as Max;
h) Minimum capacity. expressed as Min;
i) Actual interval value. d;
j) Verification interval value. e;
k) Exit-factory number;
l) Exit-factory date (or given in some form).
6.1.1.2 Necessary markings at the appropriate time
a) Power supply voltage... V;
b) Power frequency... Hz;
c) As for the balance which is composed by several independent but mutually related modules, each module shall have identification marking;
d) Special temperature limits when complying with normal working requirements.
6.1.2 Requirements for marking
6.1.2.1 Handwriting size and shape must be clear and standardized;
6.1.2.2 Signage with illustrative markings must be firm and reliable, AND it must be difficult to rub, destroy or disassemble;
6.1.2.3 Signs shall be installed (placed) in a clearly readable position on the balance.
6.2 General requirements of structure
6.2.1 Applicability
6.2.1.1 The design of the balance shall be suitable for the intended use.
6.2.1.2 The structure of the balance shall be fine and strong, AND to maintain good measurement performance in its service period;
6.2.1.3 It shall be able to place the load easily and safely on the weighing pan of the balance. As for the balance equipped with the hanging pans, it must ensure that the hanging system is firm and reliable, AND it shall not produce slippage.
6.2.2 Reliability
6.2.4.3 The balance may be provided with an interface to connect it to an external device. The measurement function and measurement data of the balance shall not be affected by the peripheral equipment, other receiving instruments, OR the interface acting on the interface.
6.2.4.4 Under the normal use conditions, the balance shall have good pressure resistance and insulation performance.
6.3 Indication of weighing results
6.3.1 Reading device
6.3.1.1 Under normal conditions of use, the reading of the weighing results
must be accurate, reliable and clear.
6.3.1.2 When the maximum capacity + 9e is exceeded, the balance shall have no numerical indication, OR otherwise indicate the overload overflow symbol.
6.3.2 Indication form
6.3.2.1 Weighing results must contain the units of measurement of mass or other symbols;
6.3.2.2 For the indication of any one of the weighing results, only one unit of measurement as selected shall be used;
6.3.2.3 When there is more than one indicating device on the balance, the indication of each indicating device must be consistent when me...
......
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 20 pages — is available in the English PDF.
Referenced standards
Cited by
- GB/T 41742-2022Low temperature sealing glass for optoelectric devices
- GB/T 9251-2022Methods for hydrostatic test of gas cylinders
- GB/T 36128-2018Regulation of mass measurement permissible errors for jewelry and precious metal products
- HJ 836-2017Stationary source emission - Determination of mass concentration of particulate matter at low concentration - Manual gravimetric method
- HJ 656-2013Technical Specifications for gravimetric measurement methods for PM2.5 in ambient air
- GB/T 29249-2012Electronic weighing moisture analyzer of oven drying
How to Download JJG 1036-2008
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
JJG 1151-2025 — Verification Regulation of Liquid Chromatograph-Atomic Fluorescence Spectrometers
JJG 1204-2025 — Verification Regulation of Electronic Price Computing Scales(for Trial Implementation)
JJG 579-2025 — Trial Case Lenses
Secure payment via Stripe
Payments accepted
JJG 1036-2008
$125.00