JJF 2133-2024 (Calibration Specification for Sensors of Ocean Data Buoys) is available as an English-translated PDF.
JJF 2133-2024 — This standard applies to the calibration of parameters such as wind direction, wind speed, air temperature, relative humidity, air pressure, wave height, wave period, water temperature, salinity, etc. of ocean data buoys.
Found what you need?
Document preview — JJF 2133-2024
National Standard of the People's Republic of China
Issued by: State Administration for Market Regulation
Contents
- Introduction (II)
- 1 Scope(1)
- 2 References(1)
- 3 Terminology and units of measurement (1)
- 3.1 Terminology (1)
- 3.2 Units of measurement(1)
- 4 Overview(2)
- 5 Metering characteristics (2)
- 5.1 Appearance(2)
- 5.2 Metering performance (2)
- 6 Calibration conditions(3)
- 6.1 Environmental conditions(3)
- 6.2 Measurement standards and main supporting equipment (3)
- 7 Calibration items and calibration methods (7)
- 7.1 Calibration items (7)
- 7.2 Appearance and functional inspection (7)
- 7.3 Wind direction calibration method (7)
- 7.4 Wind speed calibration method (8)
- 7.5 Air temperature calibration method (9)
- 7.6 Humidity calibration method (9)
- 7.7 Barometric pressure calibration method (10)
- 7.8 Wave height and wave period calibration method (10)
- 7.9 Water temperature calibration method (12)
- 7.10 Salinity calibration method (12)
- 8 Expression of calibration results (13)
- 9 Recalibration interval (13)
- Appendix A Calibration Record Sheet Reference Format (14)
- Appendix B Reference format for information on the inner pages of a calibration certificate (23)
- Appendix C Calibration Uncertainty Evaluation Example (24)
1 Scope(1)
2 References(1)
3 Terminology and units of measurement (1)
3.1 Terminology (1)
3.2 Units of measurement(1)
4 Overview(2)
5 Metering characteristics (2)
5.1 Appearance(2)
5.2 Metering performance (2)
6 Calibration conditions(3)
6.1 Environmental conditions(3)
6.2 Measurement standards and main supporting equipment (3)
7 Calibration items and calibration methods (7)
7.1 Calibration items (7)
7.2 Appearance and functional inspection (7)
7.3 Wind direction calibration method (7)
7.4 Wind speed calibration method (8)
7.5 Air temperature calibration method (9)
7.6 Humidity calibration method (9)
7.7 Barometric pressure calibration method (10)
7.8 Wave height and wave period calibration method (10)
7.9 Water temperature calibration method (12)
7.10 Salinity calibration method (12)
8 Expression of calibration results (13)
9 Recalibration interval (13)
Appendix A Calibration Record Sheet Reference Format (14)
Appendix B Reference format for information on the inner pages of a calibration certificate (23)
Appendix C Calibration Uncertainty Evaluation Example (24)
Introduction
This specification is based on JJF 1001-2011 "General metrological terms and definitions", JJF 1059.1-2012 "Measurement uncertainty it is formulated based on JJF 1071-2010 "National Measurement Calibration Specification Writing Rules".
This specification combines the ocean data buoy wind speed, wind direction, temperature, humidity, air pressure, waves, water temperature, the current status of the use of salinity sensors refers to GB/T 14914.2-2019 "Ocean Observation Specification Part 2: Seaside Observation GB/T 12763.2-2007 "Ocean Survey Specifications Part 2: Ocean Hydrological Observation", GB/T 12763.3-2020 "Ocean Survey Specifications Part 3: Marine Meteorological Observations", JJF 1794-2020 "Shore-based Marine Environmental Natural "Sensor Calibration Specifications for Dynamic Observation Systems", JJG876-2019 "Ship Meteorological Instruments", JJF 1076-2020 "Digital Calibration Specification for Digital Thermometer and Hygrometer", JJG1084-2013 Digital Barometer, JJG1144-2017 Gravity Acceleration JJG761-2016 Electrode Salinometer, JJG763-2019 Temperature, Salinity and Depth Measuring Instrument, Part of the contents of JJG (Ocean) 01-94 "FZS2.FZS1 Ocean Data Buoy Sensor" and other technical documents Formulate.
This specification is published for the first time.
Specification for calibration of ocean data buoy sensors
1 Scope
This specification applies to ocean data buoy wind direction, wind speed, temperature, relative humidity, air pressure, wave height, wave period, Calibration of sensors for parameters such as water temperature and salinity.
2 References
This specification references the following documents.
JJG876-2019 Ship Weather Instrument JJG1144-2017 Gravity Acceleration Wave Buoy for any referenced document with a date, only the version with the date is applicable to this specification; for any referenced document without a date, the latest version (including all amendments) shall apply to this specification.
3 Terminology and units of measurement
3.1 Terminology
The terms and definitions defined in JJG1144-2017 and the following apply to this specification.
Installed in the ocean data buoy, it can automatically monitor wind direction, wind speed, temperature, relative humidity, air pressure, wave height, Sensors for measuring ocean hydrological and meteorological elements such as wave period, water temperature, and salinity.
At least 100 wave heights measured continuously in a certain period are arranged in descending order, and the first 1/3 of the number after sorting is taken.
The average value of the wave height.
[Source. GB/T 15920-2010, 2.4.36, modified] the average value of each wave height of the significant wave corresponding to the period.
[Source. JJG1144-2017, 3.4]
3.2 Units of measurement Wind direction. degree, symbol is "°";
Wind speed. meters per second, symbol is "m/s";
Temperature. Celsius, symbol is "°C";
Relative humidity. symbol is "%";
Air pressure. hectopascals, symbol is "hPa";
Wave height. meter, symbol is "m";
Wave period. second, symbol is "s".
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 21 pages — is available in the English PDF.
How to Download JJF 2133-2024
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
JJF 2425-2026 — Calibration specification for carbon dioxide incubators
JJF 1183-2025 — Calibration Specification for Temperature Transmitters
JJF 1282-2025 — Calibration Specification for Time Delay Relays
Secure payment via Stripe
Payments accepted
JJF 2133-2024
$545.00