JJF 2132-2024Calibration Specification for Artificial Accelerated Weathering Apparatus of Fluorescent UV Lamps: Irradiance (English PDF)
This is a limited preview
Buy now to download the full PDF (12 pages)
Need quotation for your management?
Get a formal quotation for JJF 2132-2024 in 30 minutes.
Issued by
State Administration for Market Regulation
Level / Type
National · Mandatory
Issue date
June 14, 2024
Implementation date
December 14, 2024
Scope
JJF 2132-2024 (Calibration Specification for Artificial Accelerated Weathering Apparatus of Fluorescent UV Lamps: Irradiance) is available as an English-translated PDF.
JJF 2132-2024 — This standard applies to the calibration of radiation illumination parameters of fluorescent ultraviolet lamp artificial weather aging test devices.
Found what you need?
Document preview — JJF 2132-2024
National Standard of the People's Republic of China
Issued by: State Administration for Market Regulation
Contents
- Introduction (II)
- 1 Scope(1)
- 2 References(1)
- 3 Overview(1)
- 4 Metering characteristics (2)
- 5 Calibration conditions(2)
- 5.1 Environmental conditions(2)
- 5.2 Measurement standards and other equipment (2)
- 6 Calibration items and calibration methods (2)
- 6.1 Pre-calibration check(2)
- 6.2 Zero value error of irradiance (3)
- 6.3 Relative error of irradiance indication (correction factor) (3)
- 6.4 Irradiance non-uniformity (3)
- 7 Expression of calibration results (4)
- 8 Uncertainty assessment of calibration results (5)
- 9 Recalibration interval (5)
- Appendix A Recommended format for original records (6)
- Appendix B Recommended format for the inner pages of a calibration certificate (7)
- Appendix C Relative spectral energy distribution of different types of fluorescent UV lamps (8)
- Appendix D Examples of Measurement Uncertainty Evaluation (10)
1 Scope(1)
2 References(1)
3 Overview(1)
4 Metering characteristics (2)
5 Calibration conditions(2)
5.1 Environmental conditions(2)
5.2 Measurement standards and other equipment (2)
6 Calibration items and calibration methods (2)
6.1 Pre-calibration check(2)
6.2 Zero value error of irradiance (3)
6.3 Relative error of irradiance indication (correction factor) (3)
6.4 Irradiance non-uniformity (3)
7 Expression of calibration results (4)
8 Uncertainty assessment of calibration results (5)
9 Recalibration interval (5)
Appendix A Recommended format for original records (6)
Appendix B Recommended format for the inner pages of a calibration certificate (7)
Appendix C Relative spectral energy distribution of different types of fluorescent UV lamps (8)
Appendix D Examples of Measurement Uncertainty Evaluation (10)
Introduction
JJF 1001-2011 "General metrological terms and definitions", JJF 1032-2005 "Optical radiation metrology terminology" and Definitions", JJF 1059.1-2012 "Evaluation and Expression of Uncertainty in Measurement", JJF 1071-2010 "National Metrology the "Rules for Writing Calibration Specifications" together constitute the basic series of specifications for the formulation of this specification.
This specification is published for the first time.
Fluorescent UV lamp artificial weathering test device Calibration Specifications. Irradiance Parameters
1 Scope
This specification applies to the calibration of radiation illumination parameters of fluorescent ultraviolet lamp artificial climate aging test equipment.
2 References
This specification references the following documents.
JJF 1525 Calibration specification for radiant illumination parameters of xenon arc lamp artificial weathering test equipment GB/T 16422.1 Plastics laboratory light source exposure test method Part 1: General for any referenced document with a date, only the version with the date is applicable to this specification; for any referenced document without a date, the latest version (including all amendments) shall apply to this specification.
3 Overview
Fluorescent UV lamp artificial climate aging test device (abbreviated as aging test device) uses fluorescent UV lamp as light source.
The UV radiation in the sunlight or sunlight filtered by window glass is simulated to conduct accelerated weathering test on the material.
There are three types, type 1A (UVA-340), type 1B (UVA-351) and type 2 (UVB-313), with emission peak wavelengths of for the relative spectral energy distribution diagram of different types of fluorescent ultraviolet lamps at 340nm, 351nm and 313nm, please see Appendix C.
The aging test device is mainly composed of a fluorescent ultraviolet lamp, a sample rack, a temperature control device (including a temperature sensor, a comparator the box is divided into trapezoidal structure and rectangular structure according to the different box structures (see
Figure 1). The trapezoidal structure uses multiple sets of fluorescent UV lamps as light sources, evenly distributed on both sides of the device.
The irradiance detector is located in the middle of the sample rack, as shown in Figure 1a).
The rectangular structure has multiple fluorescent UV lamps installed on the top of the workspace, and the test samples are statically placed under the lamps.
on the sample rack, see Figure 1b).
The aging test device automatically adjusts the irradiation intensity by using a radiometer. The composition of the radiometer is detailed in Chapter 4 of JJF 1525-2015 states that the radiometer detector commonly used in aging test equipment is a multi-channel detector with There are 310 channels and 340 channels, the spectral response range is (250~400)nm, and the 310 channel monitors type 2 fluorescent UV lamp the 340-channel monitors the irradiance of type 1A and type 1B fluorescent UV lamps.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 12 pages — is available in the English PDF.
How to Download JJF 2132-2024
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
JJF 2425-2026 — Calibration specification for carbon dioxide incubators
JJF 1183-2025 — Calibration Specification for Temperature Transmitters
JJF 1282-2025 — Calibration Specification for Time Delay Relays
Secure payment via Stripe
Payments accepted
JJF 2132-2024