Valid

JJF 2126-2024Calibration Specification for Test Devices of Vehicle Travelling Data Recorders (English PDF)

Preview PDF

This is a limited preview

Buy now to download the full PDF (18 pages)

Need quotation for your management?

Get a formal quotation for JJF 2126-2024 in 30 minutes.

Issued by

State Administration for Market Regulation

Level / Type

National · Mandatory

Issue date

June 14, 2024

Implementation date

December 14, 2024

Scope

JJF 2126-2024 (Calibration Specification for Test Devices of Vehicle Travelling Data Recorders) is available as an English-translated PDF.

JJF 2126-2024 — This standard applies to the calibration of driving recorder detection devices.

Found what you need?

Document preview — JJF 2126-2024

National Standard of the People's Republic of China

Issued by: State Administration for Market Regulation

Contents

  • Introduction (II)
  • 1 Scope(1)
  • 2 References(1)
  • 3 Terms and definitions (1)
  • 4 Overview(1)
  • 5 Metering characteristics (2)
  • 5.1 Positioning deviation (2)
  • 5.2 Speed measurement deviation (2)
  • 5.3 Odometer measurement error (2)
  • 5.4 Time interval measurement error (2)
  • 5.5 Current time synchronization error (2)
  • 6 Calibration conditions(2)
  • 6.1 Environmental conditions(2)
  • 6.2 Measurement standards and other equipment (2)
  • 7 Calibration items and calibration methods (3)
  • 7.1 Calibration items (3)
  • 7.2 Calibration method (3)
  • 7.2.1 Appearance and functional inspection (3)
  • 7.2.2 Positioning deviation (3)
  • 7.2.3 Speed measurement deviation (4)
  • 7.2.4 Mileage Error (4)
  • 7.2.5 Time interval error (4)
  • 7.2.6 Current time synchronization error (5)
  • 8 Expression of calibration results (5)
  • 9 Recalibration interval (6)
  • Appendix A Calibration Raw Record Format (7)
  • Appendix B Calibration Certificate Inner Page Format (9)
  • Appendix C Uncertainty Assessment Examples (11)
  • Appendix D Standard Scenario Description (20)

1 Scope(1)

2 References(1)

3 Terms and definitions (1)

4 Overview(1)

5 Metering characteristics (2)

5.1 Positioning deviation (2)

5.2 Speed measurement deviation (2)

5.3 Odometer measurement error (2)

5.4 Time interval measurement error (2)

5.5 Current time synchronization error (2)

6 Calibration conditions(2)

6.1 Environmental conditions(2)

6.2 Measurement standards and other equipment (2)

7 Calibration items and calibration methods (3)

7.1 Calibration items (3)

7.2 Calibration method (3)

7.2.1 Appearance and functional inspection (3)
7.2.2 Positioning deviation (3)
7.2.3 Speed measurement deviation (4)
7.2.4 Mileage Error (4)
7.2.5 Time interval error (4)
7.2.6 Current time synchronization error (5)

8 Expression of calibration results (5)

9 Recalibration interval (6)

Appendix A Calibration Raw Record Format (7)

Appendix B Calibration Certificate Inner Page Format (9)

Appendix C Uncertainty Assessment Examples (11)

Appendix D Standard Scenario Description (20)

Introduction

JJF 1001-2011 "General metrological terms and definitions", JJF 1071-2010 "National metrological calibration specifications" the JJF 1059.1-2012 "Evaluation and Expression of Uncertainty in Measurement" together constitute the basis for the formulation of this specification.

The uncertainty of the measurement result is evaluated according to JJF 1059.1-2012 "Evaluation of Uncertainty in Measurement" Representation"is compiled.

This specification is published for the first time.

Calibration specification for driving recorder detection device

1 Scope

This specification applies to the calibration of driving recorder detection devices.

2 References

This specification references the following documents.

JJG238-2018 Verification Procedure for Time Interval Measuring Instruments JJG722-2018 Standard digital clock verification procedures JJF 1403 Global Navigation Satellite System (GNSS) Receiver (Time Measurement Type) Calibration Specification JJF 1471 Global Navigation Satellite System (GNSS) Signal Simulator Calibration Specification JJF 1901-2021 Specification for the calibration of pointer-type precision clocks GB/T 19056 Vehicle driving recorder test device for any referenced document with a date, only the version with the date is applicable to this specification; for any referenced document without a date, the latest version (including all amendments) shall apply to this specification.

3 Terms and definitions with GNSS receiver, wheel speed pulse sensor, etc. as the core, it is used to display or record the vehicle driving recorder A device for simulating tests using the vehicle's driving speed, time, mileage, location and other status information related to the vehicle's driving.

4 Overview

The driving recorder detection device is mainly composed of antenna, GNSS receiver, acquisition control module, display module, etc.

The driving recorder detection device is simulated and tested by comparison method. The structure and working principle are shown in Figure 1.

Figure 1 Structure and working principle of driving recorder detection device

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 18 pages — is available in the English PDF.

How to Download JJF 2126-2024

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
18 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

JJF 2126-2024

$510.00