JJF 2123-2024Calibration Specification for Lock-in Amplifiers (English PDF)

Preview PDF

This is a limited preview

Buy now to download the full PDF (26 pages)

Need quotation for your management?

Get a formal quotation for JJF 2123-2024 in 30 minutes.

Issued by

State Administration for Market Regulation

Level / Type

National · Mandatory

Issue date

June 14, 2024

Implementation date

December 14, 2024

Scope

JJF 2123-2024 (Calibration Specification for Lock-in Amplifiers) is available as an English-translated PDF.

JJF 2123-2024 — This standard applies to the calibration of phase-locked amplifiers with a frequency range below 600 MHz. I/Q demodulation amplifiers can also be used as a reference.

Found what you need?

Document preview — JJF 2123-2024

National Standard of the People's Republic of China

Issued by: State Administration for Market Regulation

Contents

  • Introduction (II)
  • 1 Scope(1)
  • 2 References(1)
  • 3 Overview(1)
  • 4 Metering characteristics (1)
  • 4.1 Time base output frequency (1)
  • 4.2 Internal reference source output frequency (1)
  • 4.3 Internal reference source output amplitude (2)
  • 4.4 Common Mode Rejection Ratio(2)
  • 4.5 Amplitude measurement(2)
  • 4.6 Phase measurement(2)
  • 4.7 DC output voltage(2)
  • 4.8 DC voltage measurement(2)
  • 4.9 Input Noise(2)
  • 5 Calibration conditions(2)
  • 5.1 Environmental conditions(2)
  • 5.2 Measurement standards and other equipment (2)
  • 6 Calibration items and calibration methods (3)
  • 6.1 Appearance and working order inspection (4)
  • 6.2 Time base output frequency (4)
  • 6.3 Internal reference source output frequency (4)
  • 6.4 Internal reference source output amplitude (4)
  • 6.5 Common Mode Rejection Ratio(5)
  • 6.6 Amplitude measurement (6)
  • 6.7 Phase measurement(8)
  • 6.8 DC output voltage(9)
  • 6.9 DC voltage measurement(9)
  • 6.10 Input noise (10)
  • 7 Expression of calibration results (10)
  • 8 Recalibration interval (11)
  • Appendix A Original Record Page Format (12)
  • Appendix B Calibration Certificate Inner Page Format (15)
  • Appendix C Examples of uncertainty assessment for calibration of major items (18)

1 Scope(1)

2 References(1)

3 Overview(1)

4 Metering characteristics (1)

4.1 Time base output frequency (1)

4.2 Internal reference source output frequency (1)

4.3 Internal reference source output amplitude (2)

4.4 Common Mode Rejection Ratio(2)

4.5 Amplitude measurement(2)

4.6 Phase measurement(2)

4.7 DC output voltage(2)

4.8 DC voltage measurement(2)

4.9 Input Noise(2)

5 Calibration conditions(2)

5.1 Environmental conditions(2)

5.2 Measurement standards and other equipment (2)

6 Calibration items and calibration methods (3)

6.1 Appearance and working order inspection (4)

6.2 Time base output frequency (4)

6.3 Internal reference source output frequency (4)

6.4 Internal reference source output amplitude (4)

6.5 Common Mode Rejection Ratio(5)

6.6 Amplitude measurement (6)

6.7 Phase measurement(8)

6.8 DC output voltage(9)

6.9 DC voltage measurement(9)

6.10 Input noise (10)

7 Expression of calibration results (10)

8 Recalibration interval (11)

Appendix A Original Record Page Format (12)

Appendix B Calibration Certificate Inner Page Format (15)

Appendix C Examples of uncertainty assessment for calibration of major items (18)

Introduction

JJF 1071-2010 "Rules for the Preparation of National Metrology and Calibration Specifications" and JJF 1059.1-2012 "Measurement Uncertainty "Degree Assessment and Representation" together constitute the basic series of standards supporting the preparation of this standard.

This specification is published for the first time.

Lock-in Amplifier Calibration Specifications

1 Scope

This specification applies to the calibration of lock-in amplifiers with a frequency range below 600MHz.

For reference.

2 References

This specification has no referenced documents.

3 Overview

The phase-locked amplifier is used to detect weak AC signals. In order to avoid the influence of noise on the measurement, the core technology used it is a phase-sensitive detection technology that uses a reference signal with the same frequency and fixed phase relationship as the signal to be measured as a reference.

The lock-in amplifier is composed of signal channel module, the reference channel module provides a reference signal as a benchmark for the phase-sensitive detector.

The reference signal can be an external source or an internal source, and the internal source is generally used by default.

Auxiliary input and output channels are used for DC output and DC measurement. The schematic diagram is shown in Figure 1.

Figure 1 Schematic diagram of the lock-in amplifier

4.Metering characteristics

4.1 Time base output frequency Maximum allowable error. ±1×10-6.

4.2 Internal reference source output frequency Frequency range. 1mHz~600MHz;

Maximum allowable error. ±1×10-6.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 26 pages — is available in the English PDF.

How to Download JJF 2123-2024

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
26 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

JJF 2123-2024

$500.00