Valid

JJF 2116-2024Calibration Specification for Specific Protein Analyzers (English PDF)

Preview PDF

This is a limited preview

Buy now to download the full PDF (13 pages)

Need quotation for your management?

Get a formal quotation for JJF 2116-2024 in 30 minutes.

Issued by

State Administration for Market Regulation

Level / Type

National · Mandatory

Issue date

June 14, 2024

Implementation date

December 14, 2024

Scope

JJF 2116-2024 (Calibration Specification for Specific Protein Analyzers) is available as an English-translated PDF.

JJF 2116-2024 — This standard applies to the calibration of the metrological performance of specific protein analyzers based on the measurement principle of immunoturbidimetry.

Found what you need?

Document preview — JJF 2116-2024

National Standard of the People's Republic of China

Issued by: State Administration for Market Regulation

Contents

  • Introduction (II)
  • 1 Scope(1)
  • 2 References(1)
  • 3 Terminology and units of measurement (1)
  • 4 Overview(1)
  • 5 Metering characteristics (2)
  • 6 Calibration conditions(2)
  • 6.1 Environmental conditions(2)
  • 6.2 Standard materials and other equipment for calibration (2)
  • 7 Calibration items and calibration methods (3)
  • 7.1 Preparation and inspection before calibration (3)
  • 7.2 Indication error of liquid filling volume and repeatability of liquid filling (3)
  • 7.3 Set temperature deviation and stability (3)
  • 7.4 Error in indication of specific protein measurements (4)
  • 7.5 Repeatability of specific protein measurements (4)
  • 7.6 Carryover rate (4)
  • 7.7 Linear correlation (5)
  • 8 Expression of calibration results (5)
  • 8.1 Calibration result processing (5)
  • 8.2 Measurement uncertainty of calibration results (5)
  • 9 Recalibration interval (6)
  • Appendix A Format and Contents of Calibration Records and Calibration Certificates (7)
  • Appendix B Examples of uncertainty assessment of the indication error measurement results of a specific protein analyzer (10)
  • Appendix C International Temperature Scale Pure Water Density Table (12)
  • Appendix D Preparation of Linear Correlation Calibration Solution (13)
  • References (14)

1 Scope(1)

2 References(1)

3 Terminology and units of measurement (1)

4 Overview(1)

5 Metering characteristics (2)

6 Calibration conditions(2)

6.1 Environmental conditions(2)

6.2 Standard materials and other equipment for calibration (2)

7 Calibration items and calibration methods (3)

7.1 Preparation and inspection before calibration (3)

7.2 Indication error of liquid filling volume and repeatability of liquid filling (3)

7.3 Set temperature deviation and stability (3)

7.4 Error in indication of specific protein measurements (4)

7.5 Repeatability of specific protein measurements (4)

7.6 Carryover rate (4)

7.7 Linear correlation (5)

8 Expression of calibration results (5)

8.1 Calibration result processing (5)

8.2 Measurement uncertainty of calibration results (5)

9 Recalibration interval (6)

Appendix A Format and Contents of Calibration Records and Calibration Certificates (7)

Appendix B Examples of uncertainty assessment of the indication error measurement results of a specific protein analyzer (10)

Appendix C International Temperature Scale Pure Water Density Table (12)

Appendix D Preparation of Linear Correlation Calibration Solution (13)

References (14)

Introduction

JJF 1071-2010 "Rules for the Preparation of National Measurement and Calibration Specifications", JJF 1001-2011 "General Measurement Terms and Definition" and JJF 1059.1-2012 "Evaluation and Expression of Uncertainty in Measurement" together constitute the basis for the formulation of this specification.

A series of basic documents.

This specification was formulated mainly with reference to GB/T 26124-2011 "Clinical Chemistry In Vitro Diagnostic Reagents (Kits)", CLSI EP06-A Evaluation of the linearity of quantitative measurement procedures. Guidance for the approval of statistical methods this specification is published for the first time.

Calibration Specifications for Specific Protein Analyzers

1 Scope

This specification applies to the calibration of the metrological performance of specific protein analyzers based on the immunoturbidimetry measurement principle.

2 References

This specification references the following documents.

JJF 1001-2011 General metrological terms and definitions JJF 1059.1-2012 Evaluation and Expression of Measurement Uncertainty JJF 1071-2010 Rules for writing national metrology and calibration specifications JJF 1265-2022 Biometric Terms and Definitions for any referenced document with a date, only the version with the date is applicable to this specification; for any referenced document without a date, the latest version (including all amendments) shall apply to this specification.

3 Terminology and units of measurement the terms and definitions defined in JJF 1001-2011, JJF 1265-2022 and the following apply to this specification.

3.1 Specific protein A general term for proteins in the body that perform certain physiological functions or exhibit pathological characteristics in disease states.

Note. Specific proteins are sometimes also called "specialty proteins".

For a given amount of a standard substance, the relationship between the measurement results obtained by two given measurement procedures and the other A property of a reference material that indicates the degree of agreement between measurement results obtained with a given substance.

Note.

1 In the definition, the given standard substance is usually the calibrator, and the other specified substance is usually the daily sample.

2 The two measurement procedures involved in the determination are based on the calibration level relationship. Usually one standard material is the next higher in the calibration level.

The other is the next level standard material (calibrator).

3 The stability of interchangeable reference materials should be monitored regularly.

[Source. JJF 1001-2011, 8.16]

4 Overview

A specific protein analyzer is a protein analysis instrument that detects the content of specific proteins in serum, plasma or urine.

The specific protein analyzer measurement methods include immunoturbidimetry, immunofluorescence, gold label method, etc.

The principle of immunoturbidimetry is to use the reaction of antigen and antibody in a special reaction system to form soluble protein.

Under the action of the polymerization promoter in the dilution system, the complex precipitates from the reaction solution to form particles, making the reaction solution turbid.

The specific protein analyzer obtains the concentration of specific protein in the sample by detecting the scattered light or transmitted light intensity of the reaction solution.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 13 pages — is available in the English PDF.

How to Download JJF 2116-2024

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
13 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

JJF 2116-2024

$330.00