Scope
JJF 2115-2024 (Calibration Specification for Liquid Chromatography-Inductively Coupled Plasma Mass Spectrometers) is available as an English-translated PDF.
JJF 2115-2024 — This standard applies to the calibration of liquid chromatography-inductively coupled plasma mass spectrometry.
Found what you need?
Document preview — JJF 2115-2024
National Standard of the People's Republic of China
Issued by: State Administration for Market Regulation
Contents
- Introduction (II)
- 1 Scope(1)
- 2 References(1)
- 3 Terminology and units of measurement (1)
- 4 Overview(1)
- 5 Metering characteristics (2)
- 6 Calibration conditions(3)
- 6.1 Environmental conditions(3)
- 6.2 Measurement standards and other equipment (3)
- 7 Calibration items and calibration methods (3)
- 7.1 Pump flow setting error and pump flow stability (3)
- 7.2 Quality Accuracy(4)
- 7.3 Oxide ion yield (4)
- 7.4 Doubly Charged Ion Yield (4)
- 7.5 Minimum detection concentration (4)
- 7.6 Measurement linearity(5)
- 7.7 Qualitative and quantitative repeatability (5)
- 8 Expression of calibration results (5)
- 9 Recalibration interval (6)
- Appendix A Reference format for LC-ICP-MS calibration raw records (7)
- Appendix B Calibration Certificate Inner Page Format (for reference) (10)
- Appendix C Preparation of mobile phase and density measurement (12)
- Appendix D Example of Preparation of Mixed Standard Solution of Arsenic Species (13)
- Appendix E Spectrum of mixed standard solution of arsenic forms (14)
- Appendix F Example of uncertainty assessment for minimum detection concentration (15)
1 Scope(1)
2 References(1)
3 Terminology and units of measurement (1)
4 Overview(1)
5 Metering characteristics (2)
6 Calibration conditions(3)
6.1 Environmental conditions(3)
6.2 Measurement standards and other equipment (3)
7 Calibration items and calibration methods (3)
7.1 Pump flow setting error and pump flow stability (3)
7.2 Quality Accuracy(4)
7.3 Oxide ion yield (4)
7.4 Doubly Charged Ion Yield (4)
7.5 Minimum detection concentration (4)
7.6 Measurement linearity(5)
7.7 Qualitative and quantitative repeatability (5)
8 Expression of calibration results (5)
9 Recalibration interval (6)
Appendix A Reference format for LC-ICP-MS calibration raw records (7)
Appendix B Calibration Certificate Inner Page Format (for reference) (10)
Appendix C Preparation of mobile phase and density measurement (12)
Appendix D Example of Preparation of Mixed Standard Solution of Arsenic Species (13)
Appendix E Spectrum of mixed standard solution of arsenic forms (14)
Appendix F Example of uncertainty assessment for minimum detection concentration (15)
Introduction
This specification is based on JJF 1001-2011 "General Metrology Terms and Definitions", JJF 1071-2010 "National Metrology Calibration Specification Writing Rules and JJF 1059.1-2012 Evaluation and Expression of Uncertainty in Measurement write.
This specification mainly refers to JJG705-2014 "Liquid Chromatograph", JJF 1159-2006 "Quadrupole Inductively Coupled GB/T 32267-2015 "Terms for the determination of performance of analytical instruments" and GB/T 34826-
2017 Technical content related to "Method for determining the performance of quadrupole inductively coupled plasma mass spectrometer".
This specification is published for the first time.
Liquid chromatography-inductively coupled plasma mass spectrometry Instrument Calibration Specifications
1 Scope
This specification applies to the calibration of liquid chromatography-inductively coupled plasma mass spectrometry.
2 References
This specification references the following documents.
JJG705-2014 Liquid Chromatograph JJF 1159-2006 Calibration specification for quadrupole inductively coupled plasma mass spectrometer GB/T 32267-2015 Terminology for determination of performance of analytical instruments GB/T 34826-2017 Method for determination of performance of quadrupole inductively coupled plasma mass spectrometer for any referenced document with a date, only the version with the date is applicable to this specification; for any referenced document without a date, the latest version (including all amendments) shall apply to this specification.
3 Terminology and units of measurement the following terms and definitions defined in GB/T 32267-2015 and GB/T 34826-2017 apply to this specification.
3.1 Atomic mass unit the rest mass of a neutral atom of the nuclide 12C in its ground state is 1/12, denoted as u.
[Source. GB/T 32267-2015, 4.1]
3.2 Mass accuracy
The deviation between the mass of an ion measured by a mass spectrometer and the theoretical value.
[Source. GB/T 32267-2015, 4.5]
3.3 Oxide ion yield when an atom of an element is ionized in plasma, the oxide ion (MO) produced is related to the single charge of the element.
The ratio of ions (M) is expressed as MO/M.
[Source. GB/T 34826-2017, 3.3] the doubly charged ions (M2) produced when atoms of an element are ionized in a plasma are the ratio of the two molecules (M) is expressed as M2/M.
[Source. GB/T 34826-2017, 3.2]
3.5 Mass-charge ratio the ratio of the mass of an ion (m) to the number of charges it carries (z) is denoted as m/z.
[Source. GB/T 32267-2015, 4.6]
4 Overview
Liquid chromatography-inductively coupled plasma mass spectrometry (LC-ICP-MS, hereinafter referred to as the combined instrument) is a liquid
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 16 pages — is available in the English PDF.
How to Download JJF 2115-2024
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
JJF 2425-2026 — Calibration specification for carbon dioxide incubators
JJF 1183-2025 — Calibration Specification for Temperature Transmitters
JJF 1282-2025 — Calibration Specification for Time Delay Relays
Secure payment via Stripe
Payments accepted
JJF 2115-2024
$480.00