Scope
JJF 2113-2024 (Calibration Specification for Gas Detectors of Acrylonitrile) is available as an English-translated PDF.
JJF 2113-2024 — This standard applies to the calibration of acrylonitrile gas detectors with a measurement upper limit of no more than 100 µmol/mol.
Found what you need?
Document preview — JJF 2113-2024
National Standard of the People's Republic of China
Issued by: State Administration for Market Regulation
Contents
- Introduction (II)
- 1 Scope(1)
- 2 Overview(1)
- 3 Metering characteristics (1)
- 3.1 Indication error (1)
- 3.2 Repeatability (1)
- 3.3 Response time(1)
- 3.4 Alarm functions and alarm values (1)
- 3.5 Drift (fixed detector only) (1)
- 4 Calibration conditions(1)
- 4.1 Environmental conditions(1)
- 4.2 Calibration measuring instruments and supporting equipment (1)
- 5 Calibration items and calibration methods (2)
- 5.1 Adjustment of the detector (2)
- 5.2 Indication error (2)
- 5.3 Repeatability (3)
- 5.4 Response time(3)
- 5.5 Alarm functions and alarm values (3)
- 5.6 Drift (fixed detector only) (3)
- 6 Expression of calibration results (3)
- 7 Recalibration interval (4)
- Appendix A Acrylonitrile Gas Detector Calibration Record (5)
- Appendix B Certificate Inner Page Format (7)
- Appendix C Evaluation of measurement uncertainty of indication error of acrylonitrile gas detector (8)
1 Scope(1)
2 Overview(1)
3 Metering characteristics (1)
3.1 Indication error (1)
3.2 Repeatability (1)
3.3 Response time(1)
3.4 Alarm functions and alarm values (1)
3.5 Drift (fixed detector only) (1)
4 Calibration conditions(1)
4.1 Environmental conditions(1)
4.2 Calibration measuring instruments and supporting equipment (1)
5 Calibration items and calibration methods (2)
5.1 Adjustment of the detector (2)
5.2 Indication error (2)
5.3 Repeatability (3)
5.4 Response time(3)
5.5 Alarm functions and alarm values (3)
5.6 Drift (fixed detector only) (3)
6 Expression of calibration results (3)
7 Recalibration interval (4)
Appendix A Acrylonitrile Gas Detector Calibration Record (5)
Appendix B Certificate Inner Page Format (7)
Appendix C Evaluation of measurement uncertainty of indication error of acrylonitrile gas detector (8)
Introduction
JJF 1071 "Rules for the Preparation of National Metrology and Calibration Specifications", JJF 1001 "General Metrology Terms and Definitions", JJF 1059.1 "Evaluation and Expression of Uncertainty in Measurement" together constitute the basic series of regulations supporting the formulation of this specification this specification was formulated with reference to GB 12358-2006 "General Technical Specifications for Gas Detection and Alarm Instruments in Workplace Environments" GB/T 50493-2019 "Petrochemical Combustible Gas and Toxic Gas Detection Alarm Design Standard" and other standards Standard.
This specification is published for the first time.
Calibration Specifications for Acrylonitrile Gas Detector
1 Scope
This specification applies to the calibration of acrylonitrile gas detectors with a measurement upper limit not exceeding 100 µmol/mol.
2 Overview
Acrylonitrile gas detector (hereinafter referred to as the detector) is mainly used to detect the concentration of acrylonitrile gas in the workplace.
It is usually composed of detection unit, signal processing unit, display unit, alarm unit, etc.
There are mainly electrochemical and photoionization (PID), etc. When the displayed value is greater than the alarm setting value, it has sound, light or vibration.
Alarm function. According to the sampling method, it can be divided into suction type and diffusion type, and according to the use method, it can be divided into fixed type and portable type.
Portable.
3.Metering characteristics
3.1 Indication error Absolute error. ±2µmol/mol;
Relative error. ±10%.
Just satisfy one of them.
3.2 Repeatability
Repeatability is no more than 3%.
3.3 Response Time
The response time shall not exceed 160s.
3.4 Alarm function and alarm value A detector with an alarm function should have an alarm setting value within its measurement range.
When the alarm setting value is reached, there should be sound, light or vibration alarm.
3.5 Drift (fixed detector only)
3.5.1 Zero drift. ±1µmol/mol.
3.5.2 Range drift. ±10%.
Note. The above indicators are not used for qualification judgment, but for reference only.
4 Calibration conditions
4.1 Environmental conditions
4.1.1 Ambient temperature. (15~35)°C.
4.1.2 Relative humidity. not more than 85%.
4.1.3 The working environment should be free of electromagnetic fields and interfering gases that may affect the normal operation of the detector, and the calibration site should be well ventilated.
And take safety measures.
4.2 Calibration measuring instruments and supporting equipment
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 11 pages — is available in the English PDF.
How to Download JJF 2113-2024
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
JJF 2425-2026 — Calibration specification for carbon dioxide incubators
JJF 1183-2025 — Calibration Specification for Temperature Transmitters
JJF 1282-2025 — Calibration Specification for Time Delay Relays
Secure payment via Stripe
Payments accepted
JJF 2113-2024
$330.00