JJF 1958-2021Calibration Specification for Cesium Atomic Frequency Standards (English PDF)
铯原子频率标准校准规范
This is a limited preview
Buy now to download the full PDF (19 pages)
Need quotation for your management?
Get a formal quotation for JJF 1958-2021 in 30 minutes.
Issued by
State Administration for Market Regulation
Level / Type
National · Mandatory
Issue date
December 28, 2021
Implementation date
June 28, 2022
Scope
JJF 1958-2021 is the English-translated version of 铯原子频率标准校准规范.
JJF 1958-2021 is the Chinese standard "Calibration Specification for Cesium Atomic Frequency Standards". Issued on 2021-12-28, in force from 2022-06-28.
Found what you need?
Document preview — JJF 1958-2021
Contents
- Introduction (II)
- 1 Scope(1)
- 2 References (1)
- 3 Overview(1)
- 4 Metrology Characteristics(2)
- 4.1 Output frequency and amplitude(2)
- 4.2 Harmonic and non-harmonic distortion(2)
- 4.3 Frequency Stability(2)
- 4.4 Phase noise(2)
- 4.5 Relative frequency deviation(3)
- 4.6 Frequency Reproducibility(3)
- 4.7 Frequency adjustment range(3)
- 4.8 Second pulse (1PPS) output(3)
- 4.9 Clock Synchronization Deviation(3)
- 5 Calibration Conditions(3)
- 5.1 Environmental conditions (3)
- 5.2 Measurement standards and other equipment(3)
- 6 Calibration items and calibration methods (4)
- 6.1 Calibration items(4)
- 6.2 Calibration method(5)
- 7 Expression of calibration results (9)
- 8 Recalibration interval (10)
- Appendix A Raw Record Format(11)
- Appendix B Calibration Certificate (Inner Page) Format (14)
- Appendix C Example of Uncertainty Evaluation of Main Calibration Items (17)
1 Scope(1)
2 References (1)
3 Overview(1)
4 Metrology Characteristics(2)
4.1 Output frequency and amplitude(2)
4.2 Harmonic and non-harmonic distortion(2)
4.3 Frequency Stability(2)
4.4 Phase noise(2)
4.5 Relative frequency deviation(3)
4.6 Frequency Reproducibility(3)
4.7 Frequency adjustment range(3)
4.8 Second pulse (1PPS) output(3)
4.9 Clock Synchronization Deviation(3)
5 Calibration Conditions(3)
5.1 Environmental conditions (3)
5.2 Measurement standards and other equipment(3)
6 Calibration items and calibration methods (4)
6.1 Calibration items(4)
6.2 Calibration method(5)
7 Expression of calibration results (9)
8 Recalibration interval (10)
Appendix A Raw Record Format(11)
Appendix B Calibration Certificate (Inner Page) Format (14)
Appendix C Example of Uncertainty Evaluation of Main Calibration Items (17)
Introduction
This specification is based on JJF 1071-2010 "Rules for Compilation of National Metrology Calibration Specifications" and JJF 1059.1-2012 "Measurement Uncertainty Evaluation and Representation" written.
This specification is a revision of JJG492-2009 "Cesium Atomic Frequency Standard". Except for editorial changes, the main technical the changes are as follows.
---According to JJG2007-2015 "Time and Frequency Measuring Instruments", the frequency accuracy is changed to relative frequency deviation;
--- Increase the calibration content of reproducibility, second pulse jitter, second pulse phase adjustment range and resolution;
--- Delete Appendix A (the principles of two frequency standard comparators) in the original regulations.
Previous releases of this specification.
---JJG492-1987;
---JJG492-2009.
Caesium Atomic Frequency Standard Calibration Specification
1 Scope
This specification applies to the calibration of cesium atomic frequency standards.
2 Reference documents this specification references the following documents.
JJF 1001-2011 General Metrology Terms and Definitions JJF 1180 Terms and Definitions of Time and Frequency Measurement JJF 1206-2018 Specification for remote calibration of time and frequency standards JJG2007-2015 Time and frequency measuring instruments for dated references, only the dated version applies to this specification; for undated references the latest version (including all amendments) applies to this specification.
3 Overview
The cesium atomic frequency standard (hereinafter referred to as the cesium frequency standard) is a passive atomic frequency standard.
The basic principle is shown in Figure 1.The physical part is mainly a cesium atom resonator, and the cesium atom in the resonator is the energy level transition occurs under the action of the microwave excitation signal, and the frequency discrimination signal corresponding to the transition frequency of the cesium atom is output; the electronic part it is mainly composed of signal demodulation, frequency control, crystal oscillator, signal modulation, frequency synthesis and other parts.
The frequency of the oscillator is locked to the transition frequency of the cesium atom. The crystal oscillator output frequency has the same level of phase as the atomic transition frequency.
For the frequency deviation and long-term stability characteristics, the output signal of the cesium frequency standard is generated after distribution and other processing, for external use.
use.
Fig.1 Basic working principle of cesium atomic frequency standard
The cesium frequency standard with second pulse (1PPS) output is also called cesium atomic clock or cesium clock, which is widely used in time-frequency, communication Information, navigation, aerospace, national defense and other scientific research, measurement fields.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 19 pages — is available in the English PDF.
How to Download JJF 1958-2021
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Fast delivery
After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
JJF 2425-2026 — Calibration specification for carbon dioxide incubators
JJF 1183-2025 — Calibration Specification for Temperature Transmitters
JJF 1282-2025 — Calibration Specification for Time Delay Relays
JJF 1958-2021
$450.00