JJF 1956-2021Calibration Specification for Hydrogen Atomic Frequency Standards (English PDF)
氢原子频率标准校准规范
This is a limited preview
Buy now to download the full PDF (18 pages)
Need quotation for your management?
Get a formal quotation for JJF 1956-2021 in 30 minutes.
Issued by
State Administration for Market Regulation
Level / Type
National · Mandatory
Issue date
December 28, 2021
Implementation date
June 28, 2022
Scope
JJF 1956-2021 is the English-translated version of 氢原子频率标准校准规范.
JJF 1956-2021 is the Chinese standard "Calibration Specification for Hydrogen Atomic Frequency Standards". Issued on 2021-12-28, in force from 2022-06-28.
Found what you need?
Document preview — JJF 1956-2021
Contents
- Introduction (II)
- 1 Scope(1)
- 2 References (1)
- 3 Overview(1)
- 4 Metrology Characteristics(2)
- 4.1 Output frequency and amplitude(2)
- 4.2 Frequency Stability(2)
- 4.3 Frequency Drift Rate(2)
- 4.4 Relative frequency deviation(2)
- 4.5 Phase noise(2)
- 4.6 Harmonic and non-harmonic distortion(2)
- 4.7 Second pulse (1PPS) output(3)
- 4.8 Clock synchronization(3)
- 5 Calibration Conditions(3)
- 5.1 Environmental conditions (3)
- 5.2 Measurement standards and other equipment(3)
- 6 Calibration items and calibration methods (4)
- 6.1 Calibration items(4)
- 6.2 Calibration method(5)
- 7 Expression of calibration results (9)
- 8 Recalibration interval (10)
- Appendix A Raw Record Format (11)
- Appendix B Calibration Certificate (Inner Page) Format (15)
- Appendix C Example of Uncertainty Evaluation of Main Calibration Items (17)
1 Scope(1)
2 References (1)
3 Overview(1)
4 Metrology Characteristics(2)
4.1 Output frequency and amplitude(2)
4.2 Frequency Stability(2)
4.3 Frequency Drift Rate(2)
4.4 Relative frequency deviation(2)
4.5 Phase noise(2)
4.6 Harmonic and non-harmonic distortion(2)
4.7 Second pulse (1PPS) output(3)
4.8 Clock synchronization(3)
5 Calibration Conditions(3)
5.1 Environmental conditions (3)
5.2 Measurement standards and other equipment(3)
6 Calibration items and calibration methods (4)
6.1 Calibration items(4)
6.2 Calibration method(5)
7 Expression of calibration results (9)
8 Recalibration interval (10)
Appendix A Raw Record Format (11)
Appendix B Calibration Certificate (Inner Page) Format (15)
Appendix C Example of Uncertainty Evaluation of Main Calibration Items (17)
Introduction
This specification is based on JJF 1071-2010 "Rules for Compilation of National Metrology Calibration Specifications" and JJF 1059.1-2012 "Measurement Uncertainty Evaluation and Representation" written.
This specification is a revision of JJG1004-2005 "Hydrogen Atomic Frequency Standard". The revisions are as follows.
---According to JJG2007-2015 "Time and Frequency Measuring Instruments", the frequency accuracy is changed to relative frequency deviation;
--- Added frequency signal amplitude, harmonic and non-harmonic distortion, second pulse amplitude and width, when second pulse rises time, second pulse jitter, clock synchronization calibration items;
--- Delete the long-distance calibration method of frequency temperature characteristics and frequency value;
---Improved the measurement methods of frequency stability, frequency drift rate and relative frequency deviation.
Previous releases of this specification.
---JJG1004-2005.
Standard Calibration Specification for Hydrogen Atomic Frequency
1 Scope
This specification applies to the calibration of hydrogen atomic frequency standards.
2 Reference documents this specification references the following documents.
JJF 1001-2011 General Metrology Terms and Definitions JJF 1180 Terms and Definitions of Time and Frequency Measurement JJF 1206-2018 Specification for remote calibration of time and frequency standards JJG2007-2015 Time and frequency measuring instruments for dated references, only the dated version applies to this specification; for undated references the latest version (including all amendments) applies to this specification.
3 Overview
The hydrogen atomic frequency standard (hereinafter referred to as the hydrogen frequency standard) is divided into active type and passive type according to its working mechanism.
The difference lies in the way the transition frequency signal is generated. the atomic resonator of the active hydrogen frequency standard is a self-sustained oscillation it can continuously output atomic transition frequency signals without external excitation, as shown in Figure 1;
The resonator needs to generate atomic transition frequency signal under the excitation of external signal, as shown in Figure 2.Both are through a set of the servo control system locks the crystal oscillator on the atomic transition frequency, and the output frequency of the crystal oscillator has the same frequency as the atomic transition frequency.
The relative frequency deviation and long-term stability characteristics of the same level, after the distribution and other processing, the output signal of the hydrogen frequency standard is generated.
number for external use.
Fig.1 Basic working principle of active hydrogen atomic frequency standard
Figure 2 Basic working principle of passive hydrogen atomic frequency standard
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 18 pages — is available in the English PDF.
How to Download JJF 1956-2021
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Fast delivery
After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
JJF 2425-2026 — Calibration specification for carbon dioxide incubators
JJF 1183-2025 — Calibration Specification for Temperature Transmitters
JJF 1282-2025 — Calibration Specification for Time Delay Relays
JJF 1956-2021
$390.00