JJF 1955-2021Calibration Specification for Infrasonic Sensors (Coupler Comparison Method) (English PDF)
次声传感器校准规范(耦合腔比较法)
This is a limited preview
Buy now to download the full PDF (2 pages)
Need quotation for your management?
Get a formal quotation for JJF 1955-2021 in 30 minutes.
Issued by
State Administration for Market Regulation
Level / Type
National · Mandatory
Issue date
December 28, 2021
Implementation date
June 28, 2022
Scope
JJF 1955-2021 is the English-translated version of 次声传感器校准规范(耦合腔比较法).
JJF 1955-2021 is the Chinese standard "Calibration Specification for Infrasonic Sensors (Coupler Comparison Method)". Issued on 2021-12-28, in force from 2022-06-28.
Found what you need?
Document preview — JJF 1955-2021
Contents
- Introduction (II)
- 1 Scope(1)
- 2 References (1)
- 3 Terms and units of measurement(1)
- 4 Overview(1)
- 5 Metrology Characteristics(2)
- 6 Calibration Conditions(2)
- 6.1 Environmental conditions (2)
- 6.2 Measurement standards and other equipment(2)
- 7 Calibration items and calibration methods (2)
- 7.1 Calibration items (2)
- 7.2 Calibration method(3)
- 8 Expression of calibration results (5)
- 8.1 Calibration records (5)
- 8.2 Calibration data processing(5)
- 8.3 Calibration certificate(5)
- 8.4 Uncertainty assessment of calibration results (5)
- 9 Recalibration interval(5)
- Appendix A Reference to Environmental Parameter Correction for Sensor Sound Pressure Sensitivity Level (6)
- Appendix B Content and Format of Calibration Record(7)
- Appendix C Contents and inner page format of calibration certificate (9)
- Appendix D Measurement Uncertainty Evaluation Example(11)
1 Scope(1)
2 References (1)
3 Terms and units of measurement(1)
4 Overview(1)
5 Metrology Characteristics(2)
6 Calibration Conditions(2)
6.1 Environmental conditions (2)
6.2 Measurement standards and other equipment(2)
7 Calibration items and calibration methods (2)
7.1 Calibration items (2)
7.2 Calibration method(3)
8 Expression of calibration results (5)
8.1 Calibration records (5)
8.2 Calibration data processing(5)
8.3 Calibration certificate(5)
8.4 Uncertainty assessment of calibration results (5)
9 Recalibration interval(5)
Appendix A Reference to Environmental Parameter Correction for Sensor Sound Pressure Sensitivity Level (6)
Appendix B Content and Format of Calibration Record(7)
Appendix C Contents and inner page format of calibration certificate (9)
Appendix D Measurement Uncertainty Evaluation Example(11)
Introduction
This specification is compiled according to the rules given in JJF 1071-2010 "Rules for Compilation of National Metrology Calibration Specifications".
This specification refers to GB/T 20441.4-2006 "Measurement Microphone Part 4: Specification for Working Standard Microphone Fan", IEC 61094-5:2016 "Electroacoustic Measurement Microphone Part 5: Sound Pressure Calibration of Working Standard Microphone "Comparative Method" and JJG1019-2007 "Working Standard Microphone (Coupled Cavity Comparison Method)".
The measurement uncertainty is evaluated and evaluated according to the requirements of JJF 1059.1-2012 "Measurement Uncertainty Evaluation and Representation".
express.
This specification is published for the first time.
Infrasound Sensor Calibration Specification (Coupled cavity comparison method)
1 Scope
This specification applies to the calibration of the coupled cavity comparison method for infrasound sensors in the frequency range of 0.01Hz to 20Hz.
2 Reference documents this specification references the following documents.
JJG1019-2007 Working standard microphone (coupled cavity comparison method) JJF 1001-2011 General Metrology Terms and Definitions JJF 1034-2020 Acoustic Metrology Terms and Definitions JJF 1059.1-2012 Evaluation and representation of measurement uncertainty GB/T 3102.7-1993 Quantities and Units of Acoustics GB/T 3947-1996 Acoustic terminology GB/T 20441.4-2006 Measurement microphones - Part 4: Specification for working standard microphones IEC 61094-5:2016 Electroacoustic measurement microphones - Part 5: Working standard microphones for sound pressure calibration for dated references, only the dated version applies to this specification; for undated references the latest version (including all amendments) applies to this specification.
3 Terminology and units of measurement this specification adopts the quantities and units specified in GB/T 3102.7.
The terms and definitions defined in JJF 1001-2011, JJF 1034-2020 and GB/T 3947-1996 and the following are applicable used in this specification.
3.1 Reference sensor Infrasound sensors with pre-measured sound pressure sensitivity.
The ratio of the root sum of the rms values of all harmonic components to the rms value of the fundamental.
4 Overview
An infrasound sensor is a sensor that can effectively detect infrasound waves. In order to meet various testing requirements, there are Capacitive, bellows box, fiber optic sensors with different working principles. The operating frequency range is generally in the 0.01Hz~20Hz, the lower limit operating frequency of the sensor for special application requirements (such as pre-earthquake prediction) can be as low as 0.001Hz.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 2 pages — is available in the English PDF.
How to Download JJF 1955-2021
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Fast delivery
After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
JJF 2425-2026 — Calibration specification for carbon dioxide incubators
JJF 1183-2025 — Calibration Specification for Temperature Transmitters
JJF 1282-2025 — Calibration Specification for Time Delay Relays
JJF 1955-2021
$390.00