Valid

JJF 1953-2021Calibration Specification for Gas Chromatographs with Sulfur Chemiluminescence Detector (English PDF)

硫化学发光检测器气相色谱仪

Preview PDF

This is a limited preview

Buy now to download the full PDF (14 pages)

Need quotation for your management?

Get a formal quotation for JJF 1953-2021 in 30 minutes.

Issued by

State Administration for Market Regulation

Level / Type

National · Mandatory

Issue date

December 28, 2021

Implementation date

June 28, 2022

Scope

JJF 1953-2021 is the English-translated version of 硫化学发光检测器气相色谱仪.

JJF 1953-2021 is the Chinese standard "Calibration Specification for Gas Chromatographs with Sulfur Chemiluminescence Detector". Issued on 2021-12-28, in force from 2022-06-28.

Found what you need?

Document preview — JJF 1953-2021

Contents

  • Introduction (II)
  • 1 Scope(1)
  • 2 References (1)
  • 3 Overview(1)
  • 4 Metrology Characteristics(1)
  • 5 Calibration Conditions(2)
  • 5.1 Environmental conditions (2)
  • 5.2 Measurement standards and other equipment(2)
  • 6 Calibration items and calibration methods (2)
  • 6.1 Oven temperature stability(3)
  • 6.2 Temperature programmed repeatability(3)
  • 6.3 Baseline Noise and Baseline Drift(3)
  • 6.4 Detection limit(3)
  • 6.5 Linearity error(5)
  • 6.6 Overall performance (retention time, peak area repeatability) (5)
  • 7 Calibration results (5)
  • 8 Recalibration interval(6)
  • Appendix A Calibration Record Format(7)
  • Appendix B Calibration Certificate Inside Page Format (9)
  • Appendix C Calculation of Slope and Intercept in Linear Regression Method(10)
  • Appendix D Example of Uncertainty Assessment for Limits of Detection (11)

1 Scope(1)

2 References (1)

3 Overview(1)

4 Metrology Characteristics(1)

5 Calibration Conditions(2)

5.1 Environmental conditions (2)

5.2 Measurement standards and other equipment(2)

6 Calibration items and calibration methods (2)

6.1 Oven temperature stability(3)

6.2 Temperature programmed repeatability(3)

6.3 Baseline Noise and Baseline Drift(3)

6.4 Detection limit(3)

6.5 Linearity error(5)

6.6 Overall performance (retention time, peak area repeatability) (5)

7 Calibration results (5)

8 Recalibration interval(6)

Appendix A Calibration Record Format(7)

Appendix B Calibration Certificate Inside Page Format (9)

Appendix C Calculation of Slope and Intercept in Linear Regression Method(10)

Appendix D Example of Uncertainty Assessment for Limits of Detection (11)

Introduction

JJF 1071 "Rules for the Compilation of National Metrology Calibration Specifications", JJF 1001 "General Metrology Terms and Definitions" and JJF 1059.1 "Assessment and Representation of Measurement Uncertainty" together constitute the basic series of regulations supporting the formulation of this specification.

Fan. This specification refers to the technical requirements and test methods of JJG700-2016 "Gas Chromatograph" in the formulation.

This specification is published for the first time.

Sulfur Chemiluminescence Detector Gas Chromatograph Calibration Specifications

1 Scope

This specification applies to the calibration of sulfur chemiluminescence detector (SCD) gas chromatographs.

2 Reference documents this specification references the following documents.

JJG700-2016 Gas Chromatograph for dated references, only the dated version applies to this specification; for undated references the latest version (including all amendments) applies to this specification.

3 Overview

The gas chromatograph uses the carrier gas to bring the sample into the chromatographic column, and uses the components in the sample to gas and fix in the chromatographic column.

The distribution and adsorption coefficients of the phases are different, and the separation is carried out by a detector. According to the retention time of each component and response values for qualitative and quantitative analysis. The gas chromatograph consists of a gas system, a sample injection system, a separation system, and a temperature control system.

system, detection system and data processing system.

Sulfur chemiluminescence detector gas chromatograph (hereinafter referred to as the instrument) is used for industrial gases, natural gas, liquefied gas, Determination of sulfide and total sulfur in coke oven gas, gasoline, diesel and other samples.

The instrument detection system is mainly composed of combustion chamber, reaction chamber, ozone generator and related gas paths. Sulfur in the sample the compound (RS) is separated by a gas chromatographic column and then enters a sulfur chemiluminescence detector, where it is formed by combustion under hydrogen-rich conditions.

Sulfur monoxide (SO) and other products, sulfur monoxide (SO) react with ozone (O3) to generate excited state SO2* and SO2* emit characteristic light signals when they return to the ground state. The main reaction mechanism is as follows.

RS O2->SO Other products SO O3->SO*2 O2 SO*2->SO2 hnu (300nm~400nm) where.

RS---Sulfide;

SO*2---excited sulfur dioxide;

hnu---light energy.

The intensity of the light signal is proportional to the content of sulfur in the sample, and can be calculated by comparing the intensity of the emitted light with the standard material.

Calculate the sulfur content in the sample.

4 Metrology characteristics refer to Table 1 for the reference index of instrument measurement performance.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 14 pages — is available in the English PDF.

How to Download JJF 1953-2021

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Fast delivery

    After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
14 pages
Fast delivery
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

JJF 1953-2021

$330.00