Valid

JJF 1952-2021Calibration Specification for Sulfur X-ray Fluorescence Spectrometry Analyzers (English PDF)

X射线荧光测硫仪校准规范

Preview PDF

This is a limited preview

Buy now to download the full PDF (9 pages)

Need quotation for your management?

Get a formal quotation for JJF 1952-2021 in 30 minutes.

Issued by

State Administration for Market Regulation

Level / Type

National · Mandatory

Issue date

December 28, 2021

Implementation date

June 28, 2022

Scope

JJF 1952-2021 is the English-translated version of X射线荧光测硫仪校准规范.

JJF 1952-2021 is the Chinese standard "Calibration Specification for Sulfur X-ray Fluorescence Spectrometry Analyzers". Issued on 2021-12-28, in force from 2022-06-28.

Found what you need?

Document preview — JJF 1952-2021

Contents

  • Introduction (II)
  • 1 Scope(1)
  • 2 References (1)
  • 3 Overview(1)
  • 4 Metrology Characteristics(1)
  • 5 Calibration Conditions(2)
  • 5.1 Environmental conditions (2)
  • 5.2 Certified Reference Materials (2)
  • 6 Calibration items and calibration methods (2)
  • 6.1 Indication error(2)
  • 6.2 Repeatability(2)
  • 6.3 Stability(3)
  • 6.4 Detection limit(3)
  • 7 Expression of calibration results (3)
  • 8 Recalibration interval(4)
  • Appendix A Calibration Raw Record Format(5)
  • Appendix B Calibration Certificate (Inner Page) Format (6)
  • Appendix Example Of Measurement Uncertainty Evaluation of Indication Error of CX-Ray Fluorescence Sulfur Meter (7)

1 Scope(1)

2 References (1)

3 Overview(1)

4 Metrology Characteristics(1)

5 Calibration Conditions(2)

5.1 Environmental conditions (2)

5.2 Certified Reference Materials (2)

6 Calibration items and calibration methods (2)

6.1 Indication error(2)

6.2 Repeatability(2)

6.3 Stability(3)

6.4 Detection limit(3)

7 Expression of calibration results (3)

8 Recalibration interval(4)

Appendix A Calibration Raw Record Format(5)

Appendix B Calibration Certificate (Inner Page) Format (6)

Appendix Example of Measurement Uncertainty Evaluation of Indication Error of CX-Ray Fluorescence Sulfur Meter (7)

Introduction

JJF 1071-2010 "Rules for the Compilation of National Metrology Calibration Standards", JJF 1001-2011 "General Metrology Terms and Definition" and JJF 1059.1-2012 "Measurement Uncertainty Evaluation and Representation" together constitute the basis for the formulation of this specification Series Specifications.

This specification refers to GB/T 11140-2008 "Determination of sulfur content in petroleum products by wavelength dispersive X-ray fluorescence Spectroscopy", GB/T 17040-2019 "Determination of Sulfur Content in Petroleum and Petroleum Products Energy Dispersive X-ray Fluorescence Light Spectroscopy", GB/T 17606-2009 "Determination of Sulfur Content in Crude Oil by Energy Dispersive X-ray Fluorescence Spectrometry", SH/T 0742-2004 "Determination of Sulfur Content in Gasoline (Energy Dispersive X-ray Fluorescence Spectrometry)" and NB/SH/T 0842-2017 "Single wavelength dispersive X-ray fluorescence spectroscopy for the determination of sulfur content in light liquid fuels" relevant content of the Law.

This specification is published for the first time.

Calibration Specification for X-ray Fluorescence Sulfur Meters

1 Scope

This specification applies to the calibration of X-ray fluorescence sulfur meters for the measurement of sulfur content in crude oil and petroleum products.

The mass fraction determination range does not exceed 5%.

2 Reference documents this specification references the following documents.

GB/T 11140-2008 Determination of sulfur content in petroleum products by wavelength dispersive X-ray fluorescence spectrometry GB/T 17040-2019 Measurement of sulfur content in petroleum and petroleum products Energy-dispersive X-ray fluorescence spectrometry GB/T 17606-2009 Determination of sulfur content in crude oil Energy dispersive X-ray fluorescence spectrometry SH/T 0742-2004 Determination of sulfur content in gasoline (energy dispersive X-ray fluorescence spectrometry) NB/SH/T 0842-2017 Determination of Sulfur Content in Light Liquid Fuels Single Wavelength Dispersive X-ray Fluorescence Light Spectroscopy for dated references, only the dated version applies to this specification; for undated references document, the latest version of which (including all amendments) applies to this document.

3 Overview

X-ray fluorescence sulfur meter is used to measure the sulfur content in crude oil and petroleum products.

Divided into energy dispersion type and wavelength dispersion type. The basic working principle is. put the sample in the X-ray beam, the X-ray the X-ray emitted by the tube excites the sulfur atoms in the sample, producing characteristic X-ray spectral lines of sulfur element, and energy dispersive X-ray fluorescence.

The optical sulfur analyzer measures the characteristic X-ray intensity and wavelength of sulfur element through an X-ray detector with a certain energy resolution.

The dispersive X-ray fluorescence sulfur analyzer measures the intensity of the sulfur Kalpha line at the wavelength of 0.5373 nm by means of crystal spectroscopy and detectors.

According to the intensity, the samples were quantitatively analyzed by X-ray fluorescence sulfur analyzer.

X-ray fluorescence sulfur analyzer (hereinafter referred to as the instrument) is mainly excited by an excitation source (including a radioactive source or a tube to excite X-rays) radiation source), disperser, sample chamber, detector and signal analysis system.

4 Metrology characteristics the metering characteristics of the instrument are shown in Table 1.

Table 1 Metrology characteristics of the instrument

Calibration item

Sulfur content

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 9 pages — is available in the English PDF.

How to Download JJF 1952-2021

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Fast delivery

    After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
9 pages
Fast delivery
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

JJF 1952-2021

$225.00