Scope
JJF 1949-2021 is the English-translated version of 水质硬度计校准规范.
JJF 1949-2021 is the Chinese standard "Calibration Specification for Water Hardness Meters". Issued on 2021-12-28, in force from 2022-06-28.
Found what you need?
Document preview — JJF 1949-2021
Contents
- Introduction (II)
- 1 Scope(1)
- 2 References (1)
- 3 Overview(1)
- 4 Metrology Characteristics(1)
- 4.1 Indication error of water hardness (1)
- 4.2 Repeatability(1)
- 4.3 Temperature indication error(1)
- 5 Calibration Conditions(1)
- 5.1 Environmental conditions (1)
- 5.2 Measuring instruments and ancillary equipment for calibration (2)
- 6 Calibration items and calibration methods (2)
- 6.1 Error of water hardness indication (2)
- 6.2 Repeatability(2)
- 6.3 Temperature indication error (3)
- 7 Expression of calibration results (3)
- 8 Recalibration interval(3)
- Appendix A Standard Solution Preparation Method(4)
- Appendix B Calibration Raw Record Format (Recommended) (5)
- Appendix C Calibration Certificate Inner Page Format (Recommended) (6)
- Appendix D Example of Measurement Uncertainty of Water Hardness Indication Error (7)
1 Scope(1)
2 References (1)
3 Overview(1)
4 Metrology Characteristics(1)
4.1 Indication error of water hardness (1)
4.2 Repeatability(1)
4.3 Temperature indication error(1)
5 Calibration Conditions(1)
5.1 Environmental conditions (1)
5.2 Measuring instruments and ancillary equipment for calibration (2)
6 Calibration items and calibration methods (2)
6.1 Error of water hardness indication (2)
6.2 Repeatability(2)
6.3 Temperature indication error (3)
7 Expression of calibration results (3)
8 Recalibration interval(3)
Appendix A Standard Solution Preparation Method(4)
Appendix B Calibration Raw Record Format (Recommended) (5)
Appendix C Calibration Certificate Inner Page Format (Recommended) (6)
Appendix D Example of Measurement Uncertainty of Water Hardness Indication Error (7)
Introduction
This specification is based on JJF 1001-2011 "General Metrology Terms and Definitions", JJF 1071-2010 "National Metrology" Calibration Specification Compilation Rules" and JJF 1059.1-2012 "Measurement Uncertainty Evaluation and Representation", refer to Tested GB 8538-2016 "National Food Safety Standard Drinking Natural Mineral Water Inspection Method", GB/T 6909-2018 "Determination of Hardness of Boiler Water and Cooling Water Analysis Method" and ASTMD1126-2017 "Standard of Water Hardness" this specification is published for the first time.
Specification for calibration of water hardness tester
1 Scope
This specification applies to the calibration of benchtop and portable water hardness testers whose measuring principle is the colorimetric or electrode method.
2 Reference documents this specification references the following documents.
GB/T 6682 Analysis Laboratory Water Specifications and Test Methods for dated references, only the dated version applies to this specification; for undated references the latest version (including all amendments) applies to this specification.
3 Overview
The total water hardness mainly refers to the total content of calcium ions and magnesium ions in the water body, of which calcium hardness is caused by calcium ions.
Magnesium hardness is caused by magnesium ions, and its common measurement units are molar concentration mmol/L or mass concentration mg/L (as CaCO3, CaO or Ca).
Water hardness tester (hereinafter referred to as hardness tester) is mainly used in food, medicine, environmental protection, chemical industry and other fields Measurement of water hardness. The hardness tester is roughly divided into two categories according to the measurement principle. One is the principle of colorimetry. calcium in water samples, Magnesium ions react with a color developer to form a compound of a specific color, and the absorbance value of the compound is similar to that of a specific wavelength.
The concentration of calcium and magnesium ions is related, and the water hardness value is obtained by measuring the absorbance value. The colorimetric hardness tester is mainly composed of a light source, a sample it is composed of a product room, a detection unit and a data processing unit. The other is the principle of the electrode method. the use of ion-selective electrodes for the relationship between the electrode potential and the water hardness content conforms to the thermodynamic Nernst equation.
water hardness value. Electrode hardness tester is mainly composed of electrodes, electronic units and (or) display units.
4 Metrology characteristics
4.1 Indication error of water hardness Colorimetric hardness tester water hardness indication error. no more than ±10%.
The error of water hardness indication value of electrode method hardness tester. no more than ±15%.
4.2 Repeatability
Colorimetric hardness tester repeatability. <=3%.
Electrode method hardness tester repeatability. <=5%.
4.3 Temperature indication error Temperature indication error does not exceed ± 0.5 °C.
Note. The above measurement characteristics requirements are for reference only, not as a basis for judgment.
5 Calibration Conditions
5.1 Environmental conditions
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 9 pages — is available in the English PDF.
How to Download JJF 1949-2021
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Fast delivery
After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
JJF 2425-2026 — Calibration specification for carbon dioxide incubators
JJF 1183-2025 — Calibration Specification for Temperature Transmitters
JJF 1282-2025 — Calibration Specification for Time Delay Relays
JJF 1949-2021
$225.00