JJF 1948-2021Calibration Specification for Gasoline Vapor Recovery Detectors (English PDF)
油气回收检测仪校准规范
This is a limited preview
Buy now to download the full PDF (15 pages)
Need quotation for your management?
Get a formal quotation for JJF 1948-2021 in 30 minutes.
Issued by
State Administration for Market Regulation
Level / Type
National · Mandatory
Issue date
December 28, 2021
Implementation date
June 28, 2022
Scope
JJF 1948-2021 is the English-translated version of 油气回收检测仪校准规范.
JJF 1948-2021 is the Chinese standard "Calibration Specification for Gasoline Vapor Recovery Detectors". Issued on 2021-12-28, in force from 2022-06-28.
Found what you need?
Document preview — JJF 1948-2021
Contents
- Introduction (II)
- 1 Scope(1)
- 2 References (1)
- 3 Terms and units of measurement(1)
- 3.1 Terminology (1)
- 3.2 Units of measurement (1)
- 4 Overview(2)
- 5 Metrology Characteristics(2)
- 5.1 Pressure measurement characteristics (2)
- 5.2 Flow measurement characteristics(2)
- 5.3 Timing error(3)
- 6 Calibration Conditions(3)
- 6.1 Environmental conditions (3)
- 6.2 Measurement standard device and supporting equipment (3)
- 7 Calibration items and calibration methods (3)
- 7.1 Pre-calibration check(3)
- 7.2 Pressure metering characteristics (4)
- 7.3 Flow measurement characteristics(5)
- 7.4 Timing error(7)
- 8 Expression of calibration results (7)
- 9 Recalibration interval(7)
- Appendix A Uncertainty Evaluation Example of Pressure Indication Error Measurement Results(8)
- Appendix B Example of Uncertainty Evaluation of Measurement Results of Cumulative Flow Indication Error of Detector(10)
- Appendix C Example of Uncertainty Evaluation of Measurement Results of Detector Instantaneous Flow Indication Error (13)
- Appendix D Vapour Recovery Detector Calibration Original Record Format (16)
- Appendix E Calibration Certificate (Inner Page) Reference Format (18)
1 Scope(1)
2 References (1)
3 Terms and units of measurement(1)
3.1 Terminology (1)
3.2 Units of measurement (1)
4 Overview(2)
5 Metrology Characteristics(2)
5.1 Pressure measurement characteristics (2)
5.2 Flow measurement characteristics(2)
5.3 Timing error(3)
6 Calibration Conditions(3)
6.1 Environmental conditions (3)
6.2 Measurement standard device and supporting equipment (3)
7 Calibration items and calibration methods (3)
7.1 Pre-calibration check(3)
7.2 Pressure metering characteristics (4)
7.3 Flow measurement characteristics(5)
7.4 Timing error(7)
8 Expression of calibration results (7)
9 Recalibration interval(7)
Appendix A Uncertainty Evaluation Example of Pressure Indication Error Measurement Results(8)
Appendix B Example of Uncertainty Evaluation of Measurement Results of Cumulative Flow Indication Error of Detector(10)
Appendix C Example of Uncertainty Evaluation of Measurement Results of Detector Instantaneous Flow Indication Error (13)
Appendix D Vapour Recovery Detector Calibration Original Record Format (16)
Appendix E Calibration Certificate (Inner Page) Reference Format (18)
Introduction
This specification is based on JJF 1071-2010 "Rules for Compilation of National Metrology Calibration Specifications", JJF 1059.1-2012 "Measurement Uncertainty Evaluation and Representation", JJF 1001-2011 "General Metrology Terms and Definitions" and other specifications.
The main technical indicators of this specification refer to GB 20952 "Gas Station Air Pollutant Emission Standard", calibration method the formulation is based on JJG633-2005 "Gas Positive Displacement Flowmeter", JJG640-2016 "Differential Pressure Flowmeter" and Technical documents such as JJG875-2019 "Digital Manometer".
This specification is published for the first time.
Specification for calibration of vapor recovery detectors
1 Scope
This specification is applicable to the oil and gas recovery of which the flow measurement principle is differential pressure type and volume type, and the pressure measurement is digital pressure gauge.
Calibration of the detector.
2 Reference documents this specification references the following documents.
JJG633-2005 Gas volumetric flowmeter JJG640-2016 Differential pressure flowmeter JJG875-2019 Digital pressure gauge GB 20952 Gas Station Air Pollutant Emission Standard for dated references, only the dated version applies to this specification; for undated references the latest version (including all amendments) applies to this specification.
3 Terminology and units of measurement
3.1 Terminology
Terms defined in JJG633-2005, JJG640-2016, JJG875-2019 and GB 20952 and the following terms and Definitions apply to this specification.
3.1.1 Oil and gas gasolinevapor [GB 20952-2007, 3.2] Volatile organic compounds (non-methane total hydrocarbons) produced during refueling, unloading, and storage of gasoline at gas stations.
The volatilized oil and gas are sealed and collected, and the oil and gas-air mixture is mixed by absorption, adsorption, condensation, etc.
The process of separation and recycling.
3.2 Units of measurement the unit of measurement is shown in Table 1.
Table 1 Units of measurement
Quantity name unit unit symbol volume Cubic meters m3 flow Liters per minute L/min Cubic meters per [hour] hour m3/h
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.
How to Download JJF 1948-2021
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Fast delivery
After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
JJF 2425-2026 — Calibration specification for carbon dioxide incubators
JJF 1183-2025 — Calibration Specification for Temperature Transmitters
JJF 1282-2025 — Calibration Specification for Time Delay Relays
JJF 1948-2021
$300.00