JJF 1947-2021Calibration Specification for Platinum-Cobalt Colorimeters (English PDF)

铂-钴色度仪校准规范

Preview PDF

This is a limited preview

Buy now to download the full PDF (11 pages)

Need quotation for your management?

Get a formal quotation for JJF 1947-2021 in 30 minutes.

Issued by

State Administration for Market Regulation

Level / Type

National · Mandatory

Issue date

December 28, 2021

Implementation date

June 28, 2022

Scope

JJF 1947-2021 is the English-translated version of 铂-钴色度仪校准规范.

JJF 1947-2021 is the Chinese standard "Calibration Specification for Platinum-Cobalt Colorimeters". Issued on 2021-12-28, in force from 2022-06-28.

Found what you need?

Document preview — JJF 1947-2021

Contents

  • Introduction (II)
  • 1 Scope(1)
  • 2 References (1)
  • 3 Units of Measure(1)
  • 4 Overview(1)
  • 5 Metrology Characteristics(1)
  • 5.1 Compatibility of cuvettes (1)
  • 5.2 Platinum-cobalt chromaticity error(1)
  • 5.3 Repeatability(1)
  • 5.4 Indication drift(2)
  • 6 Calibration Conditions(2)
  • 6.1 Calibration ambient conditions(2)
  • 6.2 Measurement standards and other equipment(2)
  • 7 Calibration items and calibration methods (2)
  • 7.1 Preparation before calibration(2)
  • 7.2 Compatibility of cuvettes (2)
  • 7.3 Platinum-cobalt chromaticity error(2)
  • 7.4 Repeatability(3)
  • 7.5 Indication drift(3)
  • 8 Expression of calibration results (3)
  • 9 Recalibration interval(4)
  • Appendix A Preparation method of platinum-cobalt color series standard solution (5)
  • Appendix B Calibration Raw Record Reference Format(6)
  • Appendix C Calibration Certificate Inner Page Format(8)
  • Appendix D Example of Calibration Uncertainty Evaluation of Platinum-Cobalt Chromaticity Error(9)

1 Scope(1)

2 References (1)

3 Units of Measure(1)

4 Overview(1)

5 Metrology Characteristics(1)

5.1 Compatibility of cuvettes (1)

5.2 Platinum-cobalt chromaticity error(1)

5.3 Repeatability(1)

5.4 Indication drift(2)

6 Calibration Conditions(2)

6.1 Calibration ambient conditions(2)

6.2 Measurement standards and other equipment(2)

7 Calibration items and calibration methods (2)

7.1 Preparation before calibration(2)

7.2 Compatibility of cuvettes (2)

7.3 Platinum-cobalt chromaticity error(2)

7.4 Repeatability(3)

7.5 Indication drift(3)

8 Expression of calibration results (3)

9 Recalibration interval(4)

Appendix A Preparation method of platinum-cobalt color series standard solution (5)

Appendix B Calibration Raw Record Reference Format(6)

Appendix C Calibration Certificate Inner Page Format(8)

Appendix D Example of Calibration Uncertainty Evaluation of Platinum-Cobalt Chromaticity Error(9)

Introduction

JJF 1071-2010 "Rules for the Compilation of National Metrology Calibration Standards", JJF 1001-2011 "General Metrology Terms and Definition" and JJF 1059.1-2012 "Measurement Uncertainty Evaluation and Representation" together constitute the support for the preparation of this specification the basic series of specifications.

This specification refers to ISO 6271:2015 "Platinum-Cobalt Grade Color for Transparent Liquids" (Clear Measurement requirements, the measurement unit adopts the platinum-cobalt chromaticity unit (Pt-CoUnit, PCU) in ISO 6271:2015.

This specification is published for the first time.

Calibration Specification for Platinum-Cobalt Colorimeters

1 Scope

This specification is applicable to platinum-cobalt color based on the principle of spectrophotometry and platinum-cobalt color within the measurement range of (0~500) Calibration of the meter.

2 Reference documents this specification cites the following documents.

GB/T 6682-2008 Specifications and test methods for water used in analytical laboratories ISO 6271:2015 Platinum-cobalt grading for color evaluation of transparent liquids (Clearliquids-Estimationof for dated references, only the dated version applies to this specification; for undated references the latest version (including all amendments) applies to this specification.

3 units of measure

The following definitions from ISO 6271:2015 apply to this specification.

Platinum-cobalt chromaticity unit Pt-CoUnit, PCU the platinum-cobalt color unit is a unit containing defined concentrations of platinum [as the chloroplatinum(IV) salt ion] and chlorine Solution color of cobalt(II) hexahydrate.

4 Overview

Platinum-cobalt colorimeter (hereinafter referred to as colorimeter) is a kind of colorimeter designed based on the principle of spectrophotometry it can be used to measure and grade the chromaticity or color of liquid chemical products, water quality, turpentine and other liquids.

Colorimeter is generally composed of light source, optical system, cuvettes, measurement chamber, photoelectric detection element and display unit.

composition. It illuminates the sample to be tested through a light source, and the transmission spectrum of the liquid in the cuvette is converted into electrical energy by the photoelectric detection element.

signal, the spectral transmittance of the sample to be measured is measured, and then processed by electronic components or software to directly calculate the sample to be measured the platinum-cobalt chromaticity value of the product is displayed by the display unit.

5 Metrology characteristics

5.1 Compatibility of cuvettes when the resolution (PCU) is less than or equal to 1, the compatibility (PCU) is less than or equal to 1; when the resolution (PCU) is greater than 1, the compatibility should be Does not cause a change in the indication value.

5.2 Platinum-Cobalt Chromaticity Error not more than ±10%.

5.3 Repeatability

Not more than 2%FS.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 11 pages — is available in the English PDF.

How to Download JJF 1947-2021

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Fast delivery

    After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
11 pages
Fast delivery
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

JJF 1947-2021

$270.00