JJF 1945-2021Calibration Specification for Blood Coagulation Analyzers (English PDF)
凝血分析仪校准规范
This is a limited preview
Buy now to download the full PDF (13 pages)
Need quotation for your management?
Get a formal quotation for JJF 1945-2021 in 30 minutes.
Issued by
State Administration for Market Regulation
Level / Type
National · Mandatory
Issue date
December 28, 2021
Implementation date
June 28, 2022
Scope
JJF 1945-2021 is the English-translated version of 凝血分析仪校准规范.
JJF 1945-2021 is the Chinese standard "Calibration Specification for Blood Coagulation Analyzers". Issued on 2021-12-28, in force from 2022-06-28.
Found what you need?
Document preview — JJF 1945-2021
Contents
- Introduction (II)
- 1 Scope(1)
- 2 References (1)
- 3 Terms (1)
- 3.1 Reaction system (1)
- 3.2 Channel(1)
- 4 Overview(1)
- 5 Metrology Characteristics(1)
- 6 Calibration Conditions(2)
- 6.1 Environmental conditions (2)
- 6.2 Calibration equipment and reagents(3)
- 7 Calibration items and calibration methods (3)
- 7.1 Temperature control(3)
- 7.2 Channel difference(3)
- 7.3 Carrying pollution rate (4)
- 7.4 Measurement repeatability(4)
- 7.5 FIB relative indication error (5)
- 7.6 FIB linearity(5)
- 8 Expression of calibration results (5)
- 8.1 Calibration result processing(5)
- 8.2 Temperature and FIB calibration uncertainty(5)
- 9 Recalibration interval(6)
- Appendix A Calibration Raw Record (Reference) Format(7)
- Appendix B Calibration Certificate Results Page (Reference) Format (9)
- Appendix C Temperature and FIB Calibration Uncertainty Evaluation Example(10)
1 Scope(1)
2 References (1)
3 Terms (1)
3.1 Reaction system (1)
3.2 Channel(1)
4 Overview(1)
5 Metrology Characteristics(1)
6 Calibration Conditions(2)
6.1 Environmental conditions (2)
6.2 Calibration equipment and reagents(3)
7 Calibration items and calibration methods (3)
7.1 Temperature control(3)
7.2 Channel difference(3)
7.3 Carrying pollution rate (4)
7.4 Measurement repeatability(4)
7.5 FIB relative indication error (5)
7.6 FIB linearity(5)
8 Expression of calibration results (5)
8.1 Calibration result processing(5)
8.2 Temperature and FIB calibration uncertainty(5)
9 Recalibration interval(6)
Appendix A Calibration Raw Record (Reference) Format(7)
Appendix B Calibration Certificate Results Page (Reference) Format (9)
Appendix C Temperature and FIB Calibration Uncertainty Evaluation Example(10)
Introduction
JJF 1071 "Rules for the Compilation of National Metrology Calibration Specifications", JJF 1001 "General Metrology Terms and Definitions" and JJF 1059.1 "Assessment and Representation of Measurement Uncertainty" together constitute the basic series of regulations supporting the formulation of this specification.
Fan. The calibration method and measurement characteristics mainly refer to JJF 1101-2019 "Temperature and Humidity Calibration of Environmental Test Equipment" Specification", YY/T 0659-2017 "Coagulation Analyzer" and CLSIH30-A2 Determination of Fibrinogen in Plasma Approvedguideline-secondedition).
This specification gives the relative indication error according to JJF 1059.1-2012 "Measurement Uncertainty Evaluation and Representation"
Example of measurement uncertainty and evaluation of calibration results.
This specification is published for the first time.
Coagulation Analyzer Calibration Specifications
1 Scope
This standard applies to the clinical analysis of blood coagulation and anticoagulation, fibrinolysis and antifibrinolysis of patients.
Calibration of coagulation analyzers, not suitable for platelet aggregation function and blood flow function testing, point-of-care testing (POCT) calibration of the instrument.
2 Reference documents this specification references the following documents.
JJF 1101-2019 Specification for temperature and humidity calibration of environmental test equipment YY/T 0659-2017 Coagulation analyzer CLSIH30-A2 Methodology Approval Guide for the Determination of Fibrinogen in Plasma - Second Edition (Procedure for dated references, only the dated version applies to this specification; for undated references the latest version (including all amendments) applies to this specification.
3 Terminology
Terms and definitions as defined in JJF 1101-2019, YY/T 0659-2017 and CLSIH30-A2 and the following apply to this specification.
3.1 reaction system the liquid phase system consisting of the sample and the added reagents is included to obtain sample-related parameters.
3.2 Channel
In one measurement cycle, the channel that can detect the reaction system and obtain the detection result.
4 Overview
The coagulation analyzer (hereinafter referred to as the analyzer) is a system used for the detection of coagulation, anticoagulation and fibrinolysis.
It can be used for the diagnosis and differential diagnosis of hemorrhagic and thrombotic diseases, monitoring and curative effect of anticoagulation and thrombolytic therapy Observations provide valuable metrics. The detection items of the coagulation analyzer should at least include PT, APTT, FIB, TT Determination. The analyzer is divided into coagulation method, chromogenic substrate method and immunoturbidimetric method according to the test method.
The degree is divided into semi-automatic analyzers and fully automatic analyzers. Semi-automatic analyzers are divided into two categories according to the number of samples that can be detected at the same time.
Single and multi-channel analyzers.
Semi-automatic analyzers are generally composed of detection units, control units, data processing, display and printing units. Complete the automatic analyzer generally consists of automatic sampling unit, detection unit, control unit, data processing, display and printing unit, etc.
composition.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 13 pages — is available in the English PDF.
How to Download JJF 1945-2021
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Fast delivery
After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
JJF 2425-2026 — Calibration specification for carbon dioxide incubators
JJF 1183-2025 — Calibration Specification for Temperature Transmitters
JJF 1282-2025 — Calibration Specification for Time Delay Relays
JJF 1945-2021
$240.00