Scope
JJF 1933-2021 (Calibration Specification for Optical Shaft Measuring Instrument) is available as an English-translated PDF.
JJF 1933-2021 — This standard applies to the calibration of optical shaft measuring instruments with a shaft diameter measurement upper limit of 150 mm and a shaft length measurement upper limit of 1000 mm.
Found what you need?
Document preview — JJF 1933-2021
National Standard of the People's Republic of China
- ICS
- 17.040
- Classification
- A 52
Issued by: State Administration for Market Regulation
Contents
- Introduction (II)
- 1 Scope(1)
- 2 References(1)
- 3 Overview(1)
- 4 Metrological characteristics(1)
- 4.1 Oblique circular runout of the rotary spindle tip (1)
- 4.2 The concentricity between the upper center axis and the rotary spindle (2)
- 4.3 Parallelism between the movement of the vertical guide rail and the line connecting the two centers (2)
- 4.4 Indication error of shaft diameter measurement (2)
- 4.5 Indication error of shaft length measurement (2)
- 4.6 Repeatability of shaft diameter measurement (2)
- 4.7 Repeatability of Shaft Length Measurement(2)
- 5 Calibration conditions(2)
- 5.1 Environmental conditions (2)
- 5.2 Calibration items and calibration standards and other equipment (2)
- 6 Calibration Items and Calibration Methods(3)
- 6.1 Oblique circular runout of the rotary spindle tip (3)
- 6.2 The concentricity between the upper center axis and the rotary spindle (3)
- 6.3 Parallelism between the movement of the vertical guide rail and the line connecting the two centers (4)
- 6.4 Indication error of shaft diameter measurement (5)
- 6.5 Indication error of shaft length measurement (5)
- 6.6 Repeatability of shaft diameter measurement (5)
- 6.7 Repeatability of Shaft Length Measurements(5)
- 7 Expression of Calibration Results(6)
- 8 Recalibration interval(6)
- Appendix A Example of Uncertainty Evaluation of Indication Error in Shaft Diameter Measurement (7)
- Appendix B Example of Uncertainty Evaluation of Indication Error in Shaft Length Measurement (10)
- Appendix C Standard shaft diameter gauge (13)
- Appendix D Standard Shaft Length Gauge(14)
- Appendix E Stepped Standard Shaft Gauge(15)
- Appendix F Calibration Certificate Contents and Inner Page Format (16)
1 Scope(1)
2 References(1)
3 Overview(1)
4 Metrological characteristics(1)
4.1 Oblique circular runout of the rotary spindle tip (1)
4.2 The concentricity between the upper center axis and the rotary spindle (2)
4.3 Parallelism between the movement of the vertical guide rail and the line connecting the two centers (2)
4.4 Indication error of shaft diameter measurement (2)
4.5 Indication error of shaft length measurement (2)
4.6 Repeatability of shaft diameter measurement (2)
4.7 Repeatability of Shaft Length Measurement(2)
5 Calibration conditions(2)
5.1 Environmental conditions (2)
5.2 Calibration items and calibration standards and other equipment (2)
6 Calibration Items and Calibration Methods(3)
6.1 Oblique circular runout of the rotary spindle tip (3)
6.2 The concentricity between the upper center axis and the rotary spindle (3)
6.3 Parallelism between the movement of the vertical guide rail and the line connecting the two centers (4)
6.4 Indication error of shaft diameter measurement (5)
6.5 Indication error of shaft length measurement (5)
6.6 Repeatability of shaft diameter measurement (5)
6.7 Repeatability of Shaft Length Measurements(5)
7 Expression of Calibration Results(6)
8 Recalibration interval(6)
Appendix A Example of Uncertainty Evaluation of Indication Error in Shaft Diameter Measurement (7)
Appendix B Example of Uncertainty Evaluation of Indication Error in Shaft Length Measurement (10)
Appendix C Standard shaft diameter gauge (13)
Appendix D Standard Shaft Length Gauge(14)
Appendix E Stepped Standard Shaft Gauge(15)
Appendix F Calibration Certificate Contents and Inner Page Format (16)
Introduction
JJF 1071-2010 "Rules for Compilation of National Metrology Calibration Standards", JJF 1001-2011 "General Metrology Terminology and Definition", JJF 1059.1-2012 "Assessment and Expression of Measurement Uncertainty" together constitute the basis for the formulation of this specification Basic series of specifications:
This specification is published for the first time:
Calibration specification for optical shaft measuring instruments
1 Scope
This specification is applicable to the measurement of optical shafts with the upper limit of shaft diameter measurement up to 150mm and the measurement limit of shaft length up to 1000mm:
Calibration of gauges:
2 References
This specification references the following documents:
JJF 1094-2002 Evaluation of Measuring Instrument Characteristics for dated references, only the dated version applies to this specification; for undated references document, its latest version (including all amendments) applies to this specification:
3 Overview
Optical shaft measuring instrument is an instrument that uses CCD and grating measuring system to measure shaft diameter and shaft length: general package Including rotary spindle (C axis) and vertical axis (Z axis), mainly composed of mechanical body, lighting system, CCD measuring system, it consists of control system and data processing system:
Figure 1 Schematic diagram of the structure and measurement principle of the optical shaft measuring instrument
1-Rotary spindle (C axis); 2-Lower top; 3-Illumination light source; 4-Up top; 5-Vertical motion guide rail;
6-Column; 7-CCD measuring system; 8-Measuring carriage (including Z axis) 0; 9-Base the schematic diagram of the structure and measurement principle of common optical shaft measuring instruments is shown in Figure 1: When working, measure the workpiece clamped at Between the two tops, the CCD measurement system and the lighting source are driven by the measurement carriage and move to the measurement position along the Z axis:
The measurement image is collected by the CCD, and the data processing system processes the image collected by the CCD and the moving distance of the grating:
The shaft diameter and shaft length of the measured workpiece are obtained:
4 Metrological characteristics
4.1 Oblique circular runout of the rotary spindle tip refer to Table 1 for the oblique circular runout requirements of the rotary spindle tip:
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.
How to Download JJF 1933-2021
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
JJF 2425-2026 — Calibration specification for carbon dioxide incubators
JJF 1183-2025 — Calibration Specification for Temperature Transmitters
JJF 1282-2025 — Calibration Specification for Time Delay Relays
Secure payment via Stripe
Payments accepted
JJF 1933-2021
$300.00