JJF 1927-2021Calibration Specification for Phantoms Used in Computed Radiography (CR) and Digital Radiography (DR) (English PDF)
医用CD/DR性能模体校准规范
This is a limited preview
Buy now to download the full PDF (17 pages)
Need quotation for your management?
Get a formal quotation for JJF 1927-2021 in 30 minutes.
Issued by
State Administration for Market Regulation
Level / Type
National · Mandatory
Issue date
October 18, 2021
Implementation date
April 18, 2022
Scope
JJF 1927-2021 is the English-translated version of 医用CD/DR性能模体校准规范.
JJF 1927-2021 is the Chinese standard "Calibration Specification for Phantoms Used in Computed Radiography (CR) and Digital Radiography (DR)". Issued on 2021-10-18, in force from 2022-04-18.
Found what you need?
Document preview — JJF 1927-2021
Contents
- 1 Scope(1)
- 2 References (1)
- 3 Terms and units of measurement(1)
- 4 Overview(1)
- 5 Metrology Characteristics(2)
- 5.1 Low contrast(2)
- 5.2 Attenuator Thickness(2)
- 5.3 Uniformity (2)
- 5.4 Test card identification error (2)
- 5.5 Line pair identification error(2)
- 6 Calibration Conditions(2)
- 6.1 Environmental conditions (2)
- 6.2 Measurement standards and other equipment(2)
- 7 Calibration items and calibration methods (3)
- 7.1 Low contrast(3)
- 7.2 Attenuator thickness(4)
- 7.3 Uniformity(4)
- 7.4 Test card identification error(4)
- 7.5 Pair identification error(5)
- 8 Expression of calibration results (5)
- 9 Recalibration interval(5)
- Introduction
1 Scope(1)
2 References (1)
3 Terms and units of measurement(1)
4 Overview(1)
5 Metrology Characteristics(2)
5.1 Low contrast(2)
5.2 Attenuator Thickness(2)
5.3 Uniformity (2)
5.4 Test card identification error (2)
5.5 Line pair identification error(2)
6 Calibration Conditions(2)
6.1 Environmental conditions (2)
6.2 Measurement standards and other equipment(2)
7 Calibration items and calibration methods (3)
7.1 Low contrast(3)
7.2 Attenuator thickness(4)
7.3 Uniformity(4)
7.4 Test card identification error(4)
7.5 Pair identification error(5)
8 Expression of calibration results (5)
9 Recalibration interval(5)
Appendix A Calibration Original Record (Recommended) Format Style (6)
Appendix B Calibration Certificate Inner Page (Recommended) Format (9)
Appendix C Measurement Uncertainty Evaluation Example(10)
Appendix D Standard Test Specimen (19)
Introduction
This specification is based on JJF 1071-2010 "Rules for Compilation of National Metrology Calibration Specifications", JJF 1001-2011 "General Compiled with Measurement Terms and Definitions", JJF 1059.1-2012 "Measurement Uncertainty Evaluation and Representation".
According to the actual situation of medical CR/DR performance phantom, the formulation of this calibration specification refers to JJG1078-2012 "Medical Digital Photography (CR, DR) System X-ray Radiation Source Verification Regulations", WS76-2020 "Medical X-ray Diagnostic Equipment Quality Control Testing Specification.
This specification is published for the first time.
Specification for calibration of medical CR/DR performance phantoms
1 Scope
This specification is applicable to medical CR/DR performance phantoms and multifunctional phantoms for medical CR/DR performance testing.
The Quantitative section relates to the calibration of the module.
2 Reference documents this specification references the following documents.
JJF 1035 Ionizing Radiation Measurement Terms and Definitions JJG1078 Medical digital photography (CR, DR) system X-ray radiation source GB/T 23903 Radiographic Image Resolution Tester WS76-2020 Specification for quality control testing of medical X-ray diagnostic equipment for dated references, only the dated version applies to this specification; for undated references the latest version (including all amendments) applies to this specification.
3 Terminology and units of measurement the terms and definitions defined in JJF 1035, JJG1078, GB/T 23903 and the following apply to this specification.
3.1 Terminology
The minimum contrast of a specified shape and area that can be distinguished from a uniform low-density background, expressed as a percentage.
3.1.2 Uniformity
The difference in the equivalent thickness of the phantom due to the phantom material and along the thickness difference, usually expressed as a percentage.
3.1.3 Line pair density densityoflinepair the total number of wire pairs per unit length in the wire pair width direction, in LP/mm.
3.2 Units of measurement Unit name of phantom geometric length. mm; symbol. mm.
4 Overview
The medical CR/DR performance phantom (hereinafter referred to as the phantom) is a systematic system for medical digital photography (CR, DR).
device that can be detected. It has holes (or protrusions), rulers, uniform areas, etc. of a specific depth, which are used to detect medical data.
Measurement of low-contrast resolution, spatial resolution, and consistency of light field and radiation field of digital photography (CR, DR) systems parameter. The phantom is generally composed of a low-contrast resolution module, a spatial resolution test plug-in, and a radiation field and light field consistency check.
It consists of test card and uniformity test plug-in.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 17 pages — is available in the English PDF.
How to Download JJF 1927-2021
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Fast delivery
After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
JJF 2425-2026 — Calibration specification for carbon dioxide incubators
JJF 1183-2025 — Calibration Specification for Temperature Transmitters
JJF 1282-2025 — Calibration Specification for Time Delay Relays
JJF 1927-2021
$390.00